![GILES GBF-35D-VH Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/giles/gbf-35d-vh/gbf-35d-vh_operation-and-service-manual_2227241013.webp)
13
Model: GBF-35D-VH, GBF-50D-VH
Ventless Hood Operation
2.2.14
Ultra Violet Lamp Cleaning (if equipped)
Clean UV Lamp at least every 30 days ...
1. Place Fryer power switch in
OFF
position.
2. Remove Filter Access Cover
3. Remove thumb screws and Lamp Guard. There is no need to remove the lamp.
4. Lightly spray a mild, non-caustic, biodegradable degreaser (such as Simple Green) onto the UV lamp
and use a dry, lint-free cloth to clean bulb.
Avoid touching bulb with bare hands
.
5. Re-install Lamp Guard and Filter Access Cover.
•
DO NOT
touch or handle UV Lamp with bare hands. Doing so will greatly reduce the life of bulb.
CAUTION
2.2.15
Ultra Violet Lamp Removal (if equipped)
1. Place Fryer power switch
in the
OFF
position.
2. Remove Filter Access Cover
.
3. Disconnect UV Lamp wiring harness from power
supply wiring harness
.
4. Remove thumb screws and UV Lamp Guard
.
5. Remove Lamp from Holding Brackets
.
5
4
3
2
1
2
3
4
5
1