Installation
Page 12
MDE-4133B Power Supply Kit M00016K003 Installation Manual • November 2003
Figure 4: M00458A00X Power Supply Assembly with Cover Removed
3
Disconnect the STP feed wire that goes to P1302 on the M00047A001 STP board (
4
Label and disconnect the 10-pin connector (P1301) on top of the STP board (
). Route
the cable through the grommet located in the side of the Power Supply Assembly housing.
Separate the 10-pin cable from the cable assembly for reinstallation.
5
Leaving the STP output wires connected, remove the M00047A001 STP board (
and
) and lay it on an insulated anti-static bag inside the dispenser.
6
One by one, remove a field 2-wire conductor from the grey field wiring block (P1302) on the
STP board and DIRECTLY attach it to its corresponding red/yellow or blue/yellow data wire
(
and
) using a small blue wire nut.
Note: When disconnecting wires, ensure that the wires are properly labeled for reinstallation.
3 Pole Self
Grounded
Terminal
Block
STP Board
Red/yellow or
blue yellow
data wires
attached here
2-wire conductors
from STP board
available here
If the STP wires are not connected to isolation relays, the STP wires will be hot even if the
pump is not powered up. Exercise extreme caution.
WARNING
!