System Hardware Installation
3-7 Removing and Installing the Heat Sink
Follow these instructions to remove/install the heat sink:
1. Loosen the captive screws securing the heat sink in place in reverse order (4
g
3
g
2
g
1).
2. Move the rotating wires into the unlatch position.
3. Lift and remove the heat sink from the system.
4. To reinstall the heat sink reverse steps 1-3 while ensuring that you tighten the captive screws in
sequential order (1
g
2
g
3
g
4) as seen in the image below.
Read the following guidelines before you begin to remove/install the heat sink:
• Always turn off the computer and unplug the power cord from the power outlet before installing
the heat sink to prevent hardware damage.
• Unplug all cables from the power outlets.
• Disconnect all telecommunication cables from their ports.
•
Place the system unit on a flat and stable surface.
• Open the system according to the instructions.
WARNING!
Failure to turn off the server before you start installing components may cause serious damage. Do
not attempt the procedures described in the following sections unless you are a qualified service
technician.
11
33
22
44
1
2
When installing the heat sink to CPU, use PHILLIPS #2-Lobe driver to tighten 4 captive nuts in
sequence as 1-4. The screw tightening torque: 10 ± 0.5 kgf-cm.
Содержание G492-Z52
Страница 1: ...G492 Z52 HPC Server 4U DP 10 x Gen4 GPU Server Broadcom solution User Manual Rev 1 0 ...
Страница 28: ... 28 System Hardware Installation 3 5 4 6 6 6 ...
Страница 30: ... 30 System Hardware Installation 3 5 4 ...
Страница 64: ... 64 BIOS Setup 5 2 7 PCI Subsystem Settings ...
Страница 75: ... 75 BIOS Setup 5 2 16 Intel R i350 Ethernet Controller ...
Страница 81: ... 81 BIOS Setup 5 3 1 CPU Common Options ...