background image

System Hardware Installation

- 26 -

3-4  Removing and Installing the Heat Sink

Follow these instructions to remove/install the heat sink:

1.  Loosen the captive screws securing the heat sink in place in reverse order (4

g

3

g

2

g

1). 

2.  Move the rotating wires into the unlatch position.
3.  Lift and remove the heat sink from the system.

Read the following guidelines before you begin to remove/install the heat sink: 
•  Always turn off the computer and unplug the power cord from the power outlet before installing 

the heat sink to prevent hardware damage.

•  Unplug all cables from the power outlets.
•  Disconnect all telecommunication cables from their ports.
• 

Place the system unit on a flat and stable surface.

•  Open the system according to the instructions.

WARNING!

 

Failure to turn off the server before you start installing components may cause serious damage. Do 

not attempt the procedures described in the following sections unless you are a qualified service 

technician.

1

2

3

4

1

2

3

Содержание G492-H80

Страница 1: ...G492 H80 HPC Server Intel DP 4U 8 x GPU Dual Root Server User Manual Rev 1 0 ...

Страница 2: ... and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check ...

Страница 3: ...guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Страница 4: ... cord extends from the server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing WARNING This equipment is intended to be used in Restrict Access Location The access can only be gained by Skill...

Страница 5: ...charge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts ESD and handling boards Always handle boards carefully They...

Страница 6: ...on if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the manufacturer s instructions ...

Страница 7: ...stalling the PCI Expansion Card 24 3 4 Removing and Installing the Heat Sink 26 3 5 Installing the CPU 28 3 6 Installing the Memory 29 3 6 1 Eight Channel Memory Configuration 29 3 6 2 Installing the Memory 30 3 6 3 Memory Population Table 30 3 6 4 Processor and Memory Module Matrix Table 31 3 7 Installing the Hard Disk Drive 32 3 8 Replacing the System Fan Module 34 3 9 Removing and Installing th...

Страница 8: ...tion 64 5 2 14 Driver Health 65 5 3 Chipset Menu 66 5 3 1 Processor Configuration 67 5 3 2 Common RefCode Configuration 70 5 3 3 UPI Configuration 71 5 3 4 Memory Configuration 72 5 3 5 IIO Configuration 75 5 3 6 Advanced Power Management Configuration 77 5 3 7 PCH Configuration 79 5 3 8 Miscellaneous Configuration 81 5 3 9 Server ME Configuration 82 5 3 10 Runtime Error Logging Settings 83 5 3 11...

Страница 9: ... 9 5 8 BIOS POST Beep code AMI standard 102 5 8 1 PEI Beep Codes 102 5 8 2 DXE Beep Codes 102 ...

Страница 10: ... dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loca...

Страница 11: ...MM modules up to 256GB supported 1 2V modules 3200 2933 2666 MHz LAN 2 x 10Gb s BASE T LAN ports Intel X550 AT2 1 x 10 100 1000 management LAN Video Integrated in Aspeed AST2600 2D Video Graphic Adapter with PCIe bus interface 1920x1200 60Hz 32bpp DDR4 SDRAM Storage 12 x 3 5 or 2 5 SATA hot swappable HDD SSD bays SATA device supported only Onboard 2 x SATA DOM supported RAID Intel SATA RAID 0 1 10...

Страница 12: ...O N A Backplane I O 12 x 3 5 or 2 5 SATA ports Bandwidth SATA 6Gb s per port TPM 1 x TPM header with SPI interface Optional TPM2 0 kit CTM010 Power Supply 3 x 2200W redundant PSUs 80 PLUS Platinum AC Input 100 127V 14A 47 63Hz 200 240V 12 6A 47 63Hz DC Output Max 1200W 100 127V 12 12V 95 6A 12Vsb 3 5A Max 2200W 200 240V 12 12V 178 1A 12Vsb 3 5A NOTE The system power supply requires C19 type power ...

Страница 13: ... Log in Linear Storage Circular Storage Policy Hardware Inventory Fan Profile System Firewall Power Consumption Power Control LDAP AD RADIUS Support Backup Restore Configuration Remote BIOS BMC CPLD Update Event Log Filter User Management Media Redirection Settings PAM Order Settings SSL Settings SMTP Settings Operating Properties Operating temperature 10 C to 35 C Operating humidity 8 80 non cond...

Страница 14: ...Hardware Installation 14 1 3 System Block Diagram ...

Страница 15: ...5 HDD4 HDD1 HDD0 HDD3 HDD2 6 1 2 4 3 5 No Description No Description 1 Front Panel LEDs and Buttons 4 USB 3 0 Port x 2 2 10GbE LAN Port x 2 5 VGA Port 3 10 100 1000 Server Management LAN Port 6 3 5 HDD Bays x 12 Go to the section 2 3 Front Panel Buttons and LEDs for detail description of function LEDs ...

Страница 16: ...System Appearance 16 2 2 Rear View 1 3 4 2 No Description 1 PCIe x16 Slot x 8 2 PSU 1 3 PSU 2 4 PSU 3 ...

Страница 17: ...e processor if the multiple bit ECC errors occur which effectively halt the server 5 HDD Status LED Green On HDD locate Blink HDD access Amber On HDD fault Green Amber Blink HDD rebuilding N A Off No HDD access or no HDD fault 6 System Status LED Green Solid On System is operating normally Amber Solid On Critical condition may indicate System fan failure System temperature Blink Non critical condi...

Страница 18: ... between system and network or no access Blink Data transmission or reception is occurring N A Off No data transmission or reception is occurring 3 1GbE Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 4 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or reception is occurring N A Off No data transmissio...

Страница 19: ...een Blinking Power supply firmware updating mode Amber AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Power supply critical event causing shut down failure OCP OVP fan failure and UVP 0 5Hz Amber Blinking Power supply warning events where the power supply continues to operate high temp high power high current and slow fan PSU LED ...

Страница 20: ...ss HDD Present No Access BLINK 2 BLINK 2 OFF OFF OFF OFF OFF OFF Low Speed 2 Hz 3 3 Rebuilding HDD Fault OFF OFF ON OFF ON OFF OFF OFF Locate Amber Green ON 1 ON OFF ON 1 OFF Green Amber Green ON 1 Green OFF Amber Amber OFF LED1 LED 2 HDD Present No HDD Green ON OFF NOTE 1 Depends on HBA Utility Spec 2 Blink cycle depends on HDD s activity signal 3 If HDD is pulled out during rebuilding the disk s...

Страница 21: ...ou are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare metal system of the computer case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to d...

Страница 22: ...n or connected to AC power Follow these instructions to remove install the chassis top cover 1 Remove the single screw securing the cover 2 Loosen the two thumbnail screws securing the top rear cover in place 3 Slide the cover towards the rear and remove the cover in the direction indicated 4 Follow steps 1 3 in reverse order to re install the top cover 1 2 2 3 3 ...

Страница 23: ...ove install the fan duct 1 Lift up to remove the fan duct 2 To install the fan duct align the rear edge of fan duct with the GPU module brackets ensuring that the arrows on the fan duct face the rear of the system as shown in the image below and then push down the fan duct into chassis until it firmly seats ...

Страница 24: ...d all power sources have been disconnected from the server prior to installing a PCIe card Failure to observe these warnings could result in personal injury or damage to equipment Follow these instructions to install the PCI Expansion card 1 Remove the two screws securing the PCIe card slot covers in place and remove the PCIe card slot covers 2 Insert the PCIe card into the selected slot Make sure...

Страница 25: ... 25 System Hardware Installation 2 3 ...

Страница 26: ...tall the heat sink Always turn off the computer and unplug the power cord from the power outlet before installing the heat sink to prevent hardware damage Unplug all cables from the power outlets Disconnect all telecommunication cables from their ports Place the system unit on a flat and stable surface Open the system according to the instructions WARNING Failure to turn off the server before you ...

Страница 27: ...ll the heat sink reverse steps 1 3 while ensuring that you tighten the captive screws in sequential order 1g2g3g4 as seen in the image below When installing the heat sink to CPU use T30 Lobe driver to tighten 4 captive nuts The screw tightening torque 8 0 5 kgf cm ...

Страница 28: ...these instructions to install the CPU 1 Align and install the processor on the carrier NOTE Apply thermal compound evenly on the top of the CPU Remove the protective cover from the underside of the heat sink 2 Carefully flip the heat sink cover Then install the carrier assembly on the bottom of the heat sink and make sure the gold arrow is located in the correct direction 3 Remove the CPU cover NO...

Страница 29: ...speed and chips be used Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage Memory modules have a foolproof design A memory module can be installed in only one direction If you are unable to insert the memory switch the direction 22 DIMM_P1_K1 DIMM_P1_K0 DIMM_P1_L1 DIMM_P1_L0 DIMM_P1_I1 DIMM_P1_I0 DIMM_P1_J1 DIMM_P1_J...

Страница 30: ...he DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 3 6 3 Memory Population Table Type Ranks Per DIMM and Data Width DIMM Capacity GB Speed MT s Voltage V Slots per Channel SPC and DIMM per Channel DPC 1DPC 2DPC 8Gb 16Gb 1 2V 1 2V RDIMM SRx8 8GB 16GB 3200 3200 RDIMM SRx4 16GB 32GB RDIMM DRx8 16GB 32GB RDIMM DRx4 32GB 64GB RDIMM 3DS 4R 8R x4 2H 64GB 4H 128G...

Страница 31: ...1 G0 H1 H0 E1 E0 F1 F0 V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V NOTE l There should be at least one DDR4 DIMM per socket l If only one DIMM is populated in a channel then populate it in the slot furthest away from CPU of that channel l Channel 0 s on each memory controller A E C G I M K O must be populated with same total capacity per channe...

Страница 32: ...ke sure that the hard disk drive is connected to the hard disk drive connector on the backplane Follow these instructions to install a 3 5 Hard Disk Drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the HDD tray 4 Align the hard disk drive with the positioning stud on the HDD tray 5 Slide the hard disk drive into the HDD tray ...

Страница 33: ...ss the release button 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the HDD tray 4 Align the hard disk drive with the positioning screw on the HDD tray 5 Secure the hard disk drive with five screws 6 Reinsert the HDD tray into the slot and close the locking lever 3 1 2 4 5 ...

Страница 34: ...pull up to remove the fan module 2 Reverse the previous steps to install the replacement fan module CAUTION Before you remove or install the system fans follow these steps Make sure the system is not turned on or connected to AC power Disconnect all necessary cable connections Failure to observe these warnings could result in personal injury or damage to the equipment 1 1 2 ...

Страница 35: ... power supply in the direction indicated 3 Pull out the power supply using the handle 4 Insert the replacement power supply firmly into the chassis Connect the AC power cord to the replacement power supply 2 1 3 4 CAUTION In order to reduce the risk of injury from electric shock disconnect AC power from the power supply before removing the power supply from the system Please see Section 2 2 Rear V...

Страница 36: ...dware Installation 36 3 10 Cable Connection 3 10 1 Motherboard to PCIe Board and Front IO Board 22 1 1 2 2 3 4 3 4 5 6 5 6 7 7 8 8 9 9 10 10 11 11 12 12 13 14 15 13 14 15 16 16 17 17 18 19 18 19 20 21 22 20 22 21 ...

Страница 37: ...e Slot Signal Cable 8 PCIe Slot Signal Cable 9 PCIe Slot Signal Cable 10 PCIe Slot Signal Cable 11 PCIe Slot Signal Cable 12 PCIe Slot Signal Cable 13 PCIe Slot Signal Cable 14 PCIe Slot Signal Cable 15 PCIe Slot Signal Cable 16 PCIe Slot Signal Cable 17 MLAN NCSI Cable 18 MB to PDB Signal Cable 19 Front Panel Signal Cable 20 Front Panel USB 3 0 Cable 21 Front Panel Power Cable 22 Front Panel VGA ...

Страница 38: ...dware Installation 38 3 10 2 Motherboard to HDD Back Plane Board 22 1 2 2 3 5 1 3 4 4 5 No Description 1 SATA HDD 0 3 2 SATA HDD 4 7 3 sSATA HDD 0 3 4 Back Plane Board Signal Cable 5 Back Plane Board Power Cable ...

Страница 39: ... 39 System Hardware Installation This page left intentionally blank ...

Страница 40: ...nector 15 2 x 3 Pin PCIe Cable Power Connector 16 2 x 4 Pin Front Panel Power Connector 17 SlimLine Connector PCIe Signal for CPU1 18 SlimLine Connector MLAN NCSI Signal 19 SlimLine Connector Miscellaneous 20 SATA DOM Connector sSATA 5 21 SATA DOM Connector sSATA 4 22 DIMM_P1_K1 DIMM_P1_K0 DIMM_P1_L1 DIMM_P1_L0 DIMM_P1_I1 DIMM_P1_I0 DIMM_P1_J1 DIMM_P1_J0 DIMM_P1_N0 DIMM_P1_N1 DIMM_P1_M0 DIMM_P1_M1...

Страница 41: ... 23 VROC RAID Upgrade Key 24 2 x 3 Pin PCIe Cable Power Connector 25 IPMB Connector 26 Serial Port Cable Connector 27 SlimLine Connector Support NVMe PCIe Signal for CPU1 28 SlimLine Connector Support NVMe PCIe Signal for CPU0 29 2 x 15 Pin HDD Back Plane Board Connector ...

Страница 42: ...IMM_P0_A0 DIMM_P0_B1 DIMM_P0_B0 DIMM_P0_F0 DIMM_P0_F1 DIMM_P0_E0 DIMM_P0_E1 DIMM_P0_H0 DIMM_P0_H1 DIMM_P0_G0 DIMM_P0_G1 CPU0 CPU1 ME_UPDATE Default Enable 1 2 3 ME Force Update Jumper MB_SW ON DIP 1 2 3 4 ON MB_SW 1 2 3 4 OFF BMC Defined SMB_SEL S3_MASK PMBUS_SEL ME_RCVR ME Recovery Mode Normal Default ON OFF Normal Default Stop ini al power on when BMC is not ready BIOS Defined CLR_CMOS Default E...

Страница 43: ...Connector U_2_3 5 SlimLine Connector U_2_4 6 SlimLine Connector U_2_5 7 SlimLine Connector U_2_6 8 SlimLine Connector U_2_7 9 SlimLine Connector U_2_8 10 SlimLine Connector U_2_9 11 SlimLine Connector U_2_10 12 SlimLine Connector U_2_11 13 SlimLine Connector SL_SAS0 14 SlimLine Connector SL_SAS1 15 SlimLine Connector SL_SAS2 4 3 1 CBP20C5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

Страница 44: ... with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this cha...

Страница 45: ... Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make changes Boot This setup page provides items for configuration of the boot sequence Save Exit Save all the changes made...

Страница 46: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Страница 47: ...and String Max CPU Speed CPU Signature Processor Core Microcode Patch Displays the technical information for the installed processor s Platform Information Processor PCH RC Revision Displays the platform information of the installed processor s and PCH Memory Information Total Memory Note2 Displays the total memory size of the installed memory Usable Memory Note2 Displays the usable memory size of...

Страница 48: ...lays LAN MAC address information System Date Sets the date following the weekday month day year format System Time Sets the system time following the hour minute second format Note2 This section will display capacity and frequency information of the memory that the customer has installed Note3 The number of LAN ports listed will depend on the motherboard system model ...

Страница 49: ...nu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode Select is set to UEFI Default When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Страница 50: ... Description Configuration Security Device Support Enable Disable BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable ...

Страница 51: ...ttings Press Enter to configure advanced items Please note that this item is configurable when COM1 Console Redirection is set to Enabled Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 VT UTF8 ANSI Default setting is VT100 Bits per second Selects the transfer rate for console redirection Options available 9600 19200 38400 57600 115200 Default...

Страница 52: ...t setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Default setting is None VT UTF8 Combo...

Страница 53: ...d Management Windows Emergency Management Services EMS Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled Serial Port for Out of Band EMS Console Redirection Settings Press Enter to configure advanced items Please note that this item i...

Страница 54: ...data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Software Xon Xoff Default setting is None ...

Страница 55: ...to Enabled allows you to configure the serial port settings When set to Disabled displays no configuration for the serial port Options available Enabled Disabled Default setting is Enabled Current Displays the serial port base I O address and IRQ Possible Configures the serial port base I O address and IRQ Use Automatic Settings IO 3F8h IRQ 4 DMA IO 3F8h IRQ 4 DMA IO 2F8h IRQ 4 DMA IO 3E8h IRQ 4 D...

Страница 56: ...oard LAN1 LAN2 I O ROM Note2 Enable Disable the onboard LAN1 LAN2 devices and initializes device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Devices Common Settings Above 4G Decoding Enable Disable memory mapped I O to 4GB or greater address space Above 4G Decoding Options available Enabled Disabled Default setting is Enabled SR IOV Support If the system has SR ...

Страница 57: ...and off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled Port 60 64 Emulation Enables the I O port 60h 64h emulation support This should be enabled for the complete USB Keyboard Legacy support for non USB aware OS Options availab...

Страница 58: ...ons available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Disabled Ipv6 HTTP Support Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled PXE boot wait time Wait time in seconds to press ESC key to abort the PXE boot Press the keys to increase o...

Страница 59: ... Post Report Configuration Parameter Description Post Report Configuration Error Message Report Post Error Message Enable Disable the POST Error Message support Options available Enabled Disabled Default setting is Enabled ...

Страница 60: ...es connected to the system NVMe OPROM Select Options available BIOS Build In NVMe Device Default setting is BIOS Build In NVMe LED Control Enable Diable user control NVMe LED This item is only available when the NVMe device direct connect to CPU Options available Enable Disable Default setting is Disable ...

Страница 61: ...o be decoded in Skip Above 4G Address VGA Space Options available Enabled Disabled Default setting is Disabled P2P Bridge IO Size Specifies P2P Bridge IO aligned to the size Options available 0x100 0x150 0x1000 Default setting is 0x1000 P2P Performance for GPU Options available Enabled Disabled Default setting is Enabled SATA HDD Security Frozen Enable Disable this item to send freeze lock command...

Страница 62: ...iguration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Discard Changes and Exit Delete Cert Client Cert Configuration Press Enter for configuration of advanced items ...

Страница 63: ... items Attempt Priority Options available Host Attempt Redfish Attempt Default setting is Host Attempt Commit Changes and Exit Host iSCSI Configuration Press Enter to configure advanced items iSCSI Initiator Name Only IQN format is accepted Range from 4 to 223 Add an Attempt Delete Attempts Change Attempt Order ...

Страница 64: ...BIOS Setup 62 5 2 12 Intel R X550 Ethernet Network Connection ...

Страница 65: ...to 15 seconds UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name Displays the technical specifications for the Network Interface Controller Chip Type Displays the technical specifications for the Network Interface Controller PCI Device ID Displays the technical spe...

Страница 66: ...g VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Remove VLAN Press Enter to remove an existing VLAN ...

Страница 67: ... 65 BIOS Setup 5 2 14 Driver Health Parameter Description Driver Health Displays driver health status of the devices controllers if installed ...

Страница 68: ... Setup 66 5 3 Chipset Menu Chipset Setup menu displays submenu options for configuring the function of Platform Controller Hub PCH Select a submenu item then press Enter to access the related submenu screen ...

Страница 69: ... 67 BIOS Setup 5 3 1 Processor Configuration ...

Страница 70: ...le Default setting is Disable L2 RF0 Prefetch Disable Options available Enable Disable Default setting is Disable Adjacent Cache Prefetch When enabled cache lines are fetched in pairs When disabled only the required cache line is fetched Options available Enable Disable Default setting is Enable DCU Streamer Prefetcher Enable Disable DCU streamer prefetcher Options available Enable Disable Default...

Страница 71: ...ter Description Debug Consent Options available Enable Disable Default setting is Disable Total Memory Encryption TME Enable Disable total memory encryption TME Options available Enabled Disabled Default setting is Disabled ...

Страница 72: ... is the default allocation Options available 1G 4G 16G 64G 256G 1024G Default setting is 256G Isoc Mode Enable Disable the Isochronous support in order to meet the QoS requirements Quality of Service Options available Auto Enable Disable Default setting is Auto Numa Non Uniform Memory Access Enable Disable Non uniform Memory Access NUMA support to improve the system performance Options available E...

Страница 73: ...s available 9 6GT s 10 4GT s 11 2GT s Auto Default setting is Auto SNC Sub NUMA Enable Disable Sub NUMA Cluster function Options available Disable Enable SNC2 2 clusters Default setting is Disable Stale AtoS Enable Disable Stale A to S directory optimization Options available Disable Enable Auto Default setting is Auto LLC dead line alloc Enable Disable fill dead lines in LLC Options available Dis...

Страница 74: ...g is Auto Enable ADR Enables the detecting and enabling of ADR Asynchronous DRAM Refresh function Options available Enable Disable Default setting is Enable Legacy ADR Mode Enable Disable the Legacy ADR Mode Options available Enable Disable Default setting is Disable Minimum System Memory Size Configures the minimum memory size Options available 2GB 4GB 6GB 8GB Default setting is 2GB ADR Data Save...

Страница 75: ...ype Displays the RAS type New SDDC Mode Enable Disable 48B SDDC ECC from ICX C0 Onwards Options available Disabled Enabled Default setting is Enabled Mirror Mode Mirror Mode will set entire 1LM memory in system to be mirrored consequently reducing the memory capacity by half Enables the Mirror Mode will disable the XPT Prefetch Options available Disabled Full Mirror Mode Partial Mirror Mode Defaul...

Страница 76: ...high bit 1 63 Press the keys to increase or decrease the desired values ADDDC Sparing Note Enable Disable ADDDC Sparing Options available Disabled Enabled Default setting is Disabled Enable ADDDC Error Injection Options available Disabled Enabled Default setting is Enabled Column Correction Disable Options available Disable Enable Default setting is Disable Set PMem Die Sparing Options available D...

Страница 77: ...S only to Chipset PCIe Root Ports Bridges Disable Programs ACS to all PCIe bridges Default setting is Enable DMA Control Opt In Flag Enable Disable DMA_CTRL_PLATFORM_OPT_IN_FLAG in DMAR table in ACPI Not compatible with Direct Device Assignment DDA Options available Enable Disable Default setting is Disable Interrupt Remapping Enable Disable the interrupt remapping support function Options availab...

Страница 78: ...uration Enable Disable Intel VMD technology Options available Enable Disable Default setting is Disable Intel VMD for Non Hotplug NVMe Note Enable Disable Intel VMD for Non Hotplug NVMe Options available Enable Disable Default setting is Disable Note This item appears when Intel VMD Configuration is set to Enable ...

Страница 79: ...nable Activate SST BF Enable Disable SST BF Options available Enable Disable Default setting is Disable Configure SST BF Note Enable Disable BIOS to configure SST BF High Priority Cores Options available Enable Disable Default setting is Enable Turbo Mode When this item is enabled the processor will automatically ramp up the clock speed of 1 2 of its processing cores to improve its performance Whe...

Страница 80: ...CPU C6 ACPI C3 report to OS Options available Disable Enable Auto Default setting is Disable Enhanced Halt State C1E Core C1E auto promotion control Takes effect after reboot Options available Enable Disable Default setting is Disable Package C State Control Press Enter to configure advanced items Package C State Configures the state for the C State package limit Options available C0 C1 state C2 s...

Страница 81: ...sabled and cannot be access the RAID setup utility at boot time RAID Mode When set to RAID the SATA controller enables both its RAID and AHCI functions You will be allowed to access the RAID setup utility at boot time Options available AHCI RAID Default setting is AHCI Alternate Device ID on RAID Note 1 Enable Disable Alternate Device ID on RAID mode Options available Enable Disable Default settin...

Страница 82: ...utility at boot time RAID Mode When set to RAID the SATA controller enables both its RAID and AHCI functions You will be allowed to access the RAID setup utility at boot time Options available AHCI RAID Default setting is AHCI Alternate Device ID on RAID Note 1 Enable Disable Alternate Device ID on RAID mode Options available Enable Disable Default setting is Disabled sSATA Port 0 1 2 3 4 5 The ca...

Страница 83: ...3 8 Miscellaneous Configuration Parameter Description Miscellaneous Configuration Active Video Selects the active video type Options available Auto Onboard Device PCIE Device Specific PCIE Device Default setting is Auto ...

Страница 84: ...lays ME Firmware status information Current State Displays ME Firmware current status information Error Code Displays ME Firmware status error code Recovery Cause Displays ME Firmware recovery cause PTT Support Displays if the system supports the Intel Platform Trust Technology Suppress PTT Commands Displays if the system supports to Bypass TPM2 commands submitting to PTT Firmware ...

Страница 85: ...onfigure advanced items WHEA Windows Hardware Error Architecture Support Enable Disable WHEA Support Options available Enable Disable Default setting is Enable Memory Error Enabling Press Enter to configure advanced items Memory Error Enable Disable Memory Error Options available Enable Disable Default setting is Enable Memory Corrected Error Enable Disable Memory Corrected Error Options available...

Страница 86: ...ote Enables and escalates Fatal Errors to error pins Options available Enable Disable Default setting is Enable Assert NMI on SERR Note Enable Disable BIOS generates a non maskable interrupt NMI and logs an error when a system error SERR occurs Options available Enable Disable Default setting is Enable Assert NMI on PERR Note Enable Disable BIOS generates a non maskable interrupt NMI and logs an e...

Страница 87: ...mp up the clock speed of 1 2 of its processing cores to improve its performance When this item is disabled the processor will not overclock any of its core Options available Enabled Disabled Default setting is Enabled CPU C6 report Enable Disable the BIOS to enable the report from the CPU C6 state ACPI C3 to the OS Options available Disabled Enabled Auto Default setting is Disabled Enhanced Halt S...

Страница 88: ... available Enabled Disabled Default setting is Enabled DCU Streamer Prefetcher Options available Enabled Disabled Default setting is Enabled Isoc Mode Enable Disable the Isochronous support in order to meet the QoS requirements Quality of Service Options available Auto Enabled Disabled Default setting is Auto Intel VT for Directed I O VT d Enable Disable the Intel VT for Directed I O VT d support ...

Страница 89: ...og Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Note2 Configures OS Watchdog Timer The value is between 1 to 30 minutes Default setting is 10 minutes OS Wtd Timer Policy Note2 Configure OS Watchdog Timer Policy Options available Reset Do Nothing Power Down Power Cycle Default setting is Reset Wait BMC Ready POST...

Страница 90: ...e advanced items View FRU Information Press Enter to view the FRU information BMC VLAN Configuration Press Enter to configure advanced items BMC network Configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Страница 91: ...ose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Delete Oldest Record Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Opti...

Страница 92: ... Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Страница 93: ...uration BMC VLAN ID Select to configure BMC VLAN ID The valid range is from 0 to 4094 When set to 0 BMC VLAN ID will be disabled BMC VLAN Priority Select to configure BMC VLAN Priority The valid range is from 0 to 7 When BMC VLAN ID is set to 0 BMC VLAN Priority will not be selected ...

Страница 94: ...ilable Unspecified Static DynamicBmcDhcp Default setting is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information Real time get BMC network...

Страница 95: ...work during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Enable Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IP...

Страница 96: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pres...

Страница 97: ... the applications that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually loa...

Страница 98: ...e Guard Ready Remove UEFI CA from DB Press Enter to remove Microsoft UEFI CA from Secure Boot DB Restore DB defaults Restore DB variable to factory defaults Secure Boot variable Displays the current status of the variables used for secure boot Platform Key PK Displays the current status of the Platform Key PK Press Enter to configure a new PK Options available Update Key Exchange Keys KEK Displays...

Страница 99: ...tabase Press Enter to configure a new DBT or load additional DBT from storage devices Options available Update Append OsRecovery Signatures Displays the current status of the OsRecovery Signature Database Press Enter to configure a new OsRecovery Signature or load additional OsRecovery Signature from storage devices Options available Update Append ...

Страница 100: ...ired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is On Quiet Boot Enable Disable showing the logo during POST Options available Enabled Disabled Default setting is Enabled Setup Flash Press Enter to run setup flash Dump full Setup Data Press Enter to dump full setup data to file Dump non default Setup Data Press Enter to dump non ...

Страница 101: ... the boot order priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Страница 102: ...Discard Changes and Exit Discards changes made and exits the BIOS setup Options available Yes No Save Changes and Reset Restarts the system after saving the changes made Options available Yes No Discard Changes and Reset Restarts the system without saving any changes Options available Yes No Save Changes Saves changes done so far to any of the setup options Options available Yes No Discard Changes...

Страница 103: ...ese settings the system might not function properly Options available Yes No Save as User Defaults Saves the changes made as the user default settings Options available Yes No Restore User Defaults Loads the user default settings for all BIOS setup parameters Options available Yes No Boot Override Press Enter to configure the device as the boot up drive Launch EFI Shell from filesystem device Atte...

Страница 104: ... Recovery failed 4 S3 Resume failed 7 Reset PPI is not available of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource requirements cannot be met 5 8 BIOS POST Beep code AMI standard 5 8 1 PEI Beep Co...

Отзывы: