GENERAL RULES 

1. WARNINGS 

 

 

This handbook, which is divided into two parts, is an 
essential integral part of the product. Please read all the 
information carefully as it contains important indications on 
safety during installation and use. Store this handbook in a 
safe place for future reference. The boiler must be installed 
in compliance with current regulations and following the 
manufacturer's instructions. Wrong installation may cause 
injury or damage, for which the manufacturer can not be 
held liable. 

 

Unwrap all the parts and check the contents. 

 

In case of doubt, do not use the boiler and return it to the 
supplier. 

 

Packaging elements, such as wooden crates, nails, 
staples, plastic bags and foam plastic, are a hazard and 
must not be left within the reach of children. 

 

This boiler must only be used for the purpose for which it 
was designed and built. Any other use is considered 
improper and thus hazardous. The manufacturer can not 
be held responsible for damage or injury caused by 
improper or unreasonable use. 

 

Before carrying out any cleaning or maintenance 
operations, always disconnect the boiler from the mains 
supply.

 

 

Do not obstruct the air intakes or ventilation pipes. 

 

If the boiler malfunctions or breaks down, deactivate it 
immediately. Never attempt to repair it yourself. A profes-
sionally qualified person needs to be called in. If any parts 
need repairing, this must be done by a servicing centre 
authorised by the manufacturer, using original spare parts. 
If this is not done, safe operation of the boiler may well be 
affected. 

 

In order to ensure efficiency and correct operation, it is vital 
to follow the manufacturer's instructions. The boiler must 
be serviced periodically by a properly qualified person. If 
you decide not to use the boiler any longer, all parts that 
are likely to cause a hazard must be rendered harmless. 

 

If the boiler is to be sold or transferred to another owner, or 
if you move and leave the boiler where it is, always check 
that the handbook remains with the boiler so that it can be 
consulted by the new owner or installer. 

 

Original accessories and spare parts must always be used 
for boilers with optionals or kits (including electrical ones). 

 WARNING.

 If there is the risk of freezing, always take the 

necessary measures, such as adding antifreeze or 
emptying the system.

 

2. GENERAL 

DESCRIPTION 

(fig. 1)

  

These water boilers with a non-pressurised furnace are built on 
the basis of advanced principles of heat engineering. In 
particular, they are very popular due to their high output and 
considerable cost saving, ease of installation and 
maintenance, and the fact that they can use any type of 
approved burner. 
The boilers described in this manual are designed so that they 
can be serviced from the front. The burner is mounted on the 
door which can open to the right or left as required.  

NOTES:

 

 

  The terms right and left, front and back refer 

to a person facing the boiler from the door 
side. 

  The numbers in the descriptions correspond to 

the numbers shown on the exploded diagrams 
for assembly and spare parts.

 

The shell of the boiler is comprised of elements arranged in 
sequence, starting from the front. 
The combustion chamber 

"A"

 (or furnace) is the horizontal 

cylindrical type on the lower side of the shell. The combustion 
gases lap the bottom (1) of the furnace, are deflected towards 
the outer passages of the elements (31) to the front door (20) 
and then conveyed into the inner passages of the elements 
(31) before entering the exhaust pipe 

"B".

 

The circuit of combustion gas is called «three combustion gas 
passes» and the entire course is surrounded by the water 
circuit. 
The boiler shell is thermally insulated and radiation loss is 
negligible, in full compliance with EN 303 which prescribes 
maximum temperature for handles and the jacket.

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

MANUFACTURER

SERIAL NUMBER

MODEL

P

O

W

E

R

Содержание GIEGA NTG 114

Страница 1: ...GIEGA NTG 82 220 kW GAS OR OIL BOILER INSTALLATION AND MAINTENANCE HANDBOOK 1312 1312AS2413 711292...

Страница 2: ...20 1 A B 1400 GIEGA NTG 180 GIEGA NTG 200 GIEGA NTG 220 1372 1494 1616 1540 1650 B A 450 500 max 70 224 170 N 4 M10 302 154 N 4 M8 150 50 52 47 51 53 18 20 16 17 22 27 35 36 Fig 1 Fig 2 Fig 3 Fig 4...

Страница 3: ...1 7 6 2 3 4 5 6 7 2 3 10 8 5 4 9 Fig 5 Fig 6 Fig 8 Fig 7 Fig 9...

Страница 4: ...58 57 24 25 26 63 10 Fig 10 Fig 11 Fig 12 Fig 13...

Страница 5: ...40 55 65 24 25 40 55 65 63 45 46 44 65 56 65 Fig 14 Fig 18 Fig 17 Fig 16 Fig 15...

Страница 6: ...43 42 37 38 Fig 19 Fig 23 Fig 22 Fig 21 Fig 20...

Страница 7: ...11 12 18 19 20 15 16 21 22 23 27 35 36 12 1 2 3 4 5 6 7 8 9 10 11 12 13 17 15 28 29 30 31 32 33 32 33 5 4 13 29 37 38 GIEGA NTG Expl 1...

Страница 8: ...a hazard must be rendered harmless If the boiler is to be sold or transferred to another owner or if you move and leave the boiler where it is always check that the handbook remains with the boiler s...

Страница 9: ...opping up water are as follows Appearance clear Total hardness max 20 F Free oxygen max 0 005 mg l Organic substances max 0 5 mg l pH min 8 5 6 CONTROL PANEL fig 3 The pre wired control panel comes wi...

Страница 10: ...6 50 60 77 90 100 Load loss on water side t 10 C Pa 800 1500 2200 3000 3900 11500 12500 14000 Load loss on water side t 20 C Pa 300 400 550 600 700 10000 11000 12000 Number of elements N 6 7 8 9 10 11...

Страница 11: ...e the doors 20 18 are to open Mount the M12x130 tie rods 23 using the nuts 11 and washers 12 On the other side mount the eyebolts 13 and tighten them temporarily using the nuts 11 and washers 12 3 Mou...

Страница 12: ...ING Connect the power cable to the control panel of the heating plant To connect the burner follow the instructions in the booklet provided with the burner CAUTION must be earthed 18 FILLING AND START...

Страница 13: ...M16x845 GIEGA NTG 82 45 Control panel 711327 Tie rod M16x965 GIEGA NTG 98 46 711852 Control panel support 711328 Tie rod M16x1090 GIEGA NTG 114 47 Thermometer 711329 Tie rod M16x1210 GIEGA NTG 132 50...

Страница 14: ...GIEGA NTG 82 220 kW MANTEMENIOI 1312 1312AS2413...

Страница 15: ...1 2 1 3 4 5 1 31 20 31 B EN 303 MANUFACTURER SERIAL NUMBER MODEL POWER...

Страница 16: ...4 2 diesel 1 4 E 20 C NHV 10210 kCal kl NHV 8570 kCal NM 3 2 5 20 25 F a b c max 20 F max 0 005 mg l max 0 5 mg l PH min 8 5 6 3 ON OFF 51 50 manual 52 47 7 3 4 max 5 bar 51 I 50 47 50 50 60 C 51 O 16...

Страница 17: ...0 1 0 1 0 1 0 1 0 1 0 1 pf Pa 39 40 46 50 60 77 90 100 t 10 C Pa 800 1500 2200 3000 3900 11500 12500 14000 t 20 C Pa 300 400 550 600 700 10000 11000 12000 N 6 7 8 9 10 11 12 13 kg 340 383 425 467 510...

Страница 18: ...23 7 4 5 kgm 50 NM 8 1 1 4 15 30 28 16 2 12 2 1 35 12x1300 20 36 12x1070 18 D 2 20 18 M12x130 23 11 12 13 11 12 3 20 18 13 29 14 13 4 6 7 27 n 4 6 n 2 7 7 5 21 3 2 12 13 14 15 16 17 18 19 1 57 2 24 2...

Страница 19: ...16 17 18 fig 3 5 R 51 50...

Страница 20: ...NTG 98 46 711852 Control panel support 711328 Tie rod M16x1090 GIEGA NTG 114 47 Thermometer 711329 Tie rod M16x1210 GIEGA NTG 132 50 Regulation thermostat 711330 Tie rod M16x1330 GIEGA NTG 150 51 ON...

Отзывы: