Giersch GIEGA NTG 114 Скачать руководство пользователя страница 2

20

1

A

B

1400

GIEGA NTG 180

GIEGA NTG 200

GIEGA NTG 220

1372
1494
1616

1540
1650

B

A

45

0

÷

50

0

max 70

22

4

17

0

N° 4 M10

30

2

15

4

N°4 M8

15

0

50

52

47

51

53

18

20

16

17

22

27

35

36

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Содержание GIEGA NTG 114

Страница 1: ...GIEGA NTG 82 220 kW GAS OR OIL BOILER INSTALLATION AND MAINTENANCE HANDBOOK 1312 1312AS2413 711292...

Страница 2: ...20 1 A B 1400 GIEGA NTG 180 GIEGA NTG 200 GIEGA NTG 220 1372 1494 1616 1540 1650 B A 450 500 max 70 224 170 N 4 M10 302 154 N 4 M8 150 50 52 47 51 53 18 20 16 17 22 27 35 36 Fig 1 Fig 2 Fig 3 Fig 4...

Страница 3: ...1 7 6 2 3 4 5 6 7 2 3 10 8 5 4 9 Fig 5 Fig 6 Fig 8 Fig 7 Fig 9...

Страница 4: ...58 57 24 25 26 63 10 Fig 10 Fig 11 Fig 12 Fig 13...

Страница 5: ...40 55 65 24 25 40 55 65 63 45 46 44 65 56 65 Fig 14 Fig 18 Fig 17 Fig 16 Fig 15...

Страница 6: ...43 42 37 38 Fig 19 Fig 23 Fig 22 Fig 21 Fig 20...

Страница 7: ...11 12 18 19 20 15 16 21 22 23 27 35 36 12 1 2 3 4 5 6 7 8 9 10 11 12 13 17 15 28 29 30 31 32 33 32 33 5 4 13 29 37 38 GIEGA NTG Expl 1...

Страница 8: ...a hazard must be rendered harmless If the boiler is to be sold or transferred to another owner or if you move and leave the boiler where it is always check that the handbook remains with the boiler s...

Страница 9: ...opping up water are as follows Appearance clear Total hardness max 20 F Free oxygen max 0 005 mg l Organic substances max 0 5 mg l pH min 8 5 6 CONTROL PANEL fig 3 The pre wired control panel comes wi...

Страница 10: ...6 50 60 77 90 100 Load loss on water side t 10 C Pa 800 1500 2200 3000 3900 11500 12500 14000 Load loss on water side t 20 C Pa 300 400 550 600 700 10000 11000 12000 Number of elements N 6 7 8 9 10 11...

Страница 11: ...e the doors 20 18 are to open Mount the M12x130 tie rods 23 using the nuts 11 and washers 12 On the other side mount the eyebolts 13 and tighten them temporarily using the nuts 11 and washers 12 3 Mou...

Страница 12: ...ING Connect the power cable to the control panel of the heating plant To connect the burner follow the instructions in the booklet provided with the burner CAUTION must be earthed 18 FILLING AND START...

Страница 13: ...M16x845 GIEGA NTG 82 45 Control panel 711327 Tie rod M16x965 GIEGA NTG 98 46 711852 Control panel support 711328 Tie rod M16x1090 GIEGA NTG 114 47 Thermometer 711329 Tie rod M16x1210 GIEGA NTG 132 50...

Страница 14: ...GIEGA NTG 82 220 kW MANTEMENIOI 1312 1312AS2413...

Страница 15: ...1 2 1 3 4 5 1 31 20 31 B EN 303 MANUFACTURER SERIAL NUMBER MODEL POWER...

Страница 16: ...4 2 diesel 1 4 E 20 C NHV 10210 kCal kl NHV 8570 kCal NM 3 2 5 20 25 F a b c max 20 F max 0 005 mg l max 0 5 mg l PH min 8 5 6 3 ON OFF 51 50 manual 52 47 7 3 4 max 5 bar 51 I 50 47 50 50 60 C 51 O 16...

Страница 17: ...0 1 0 1 0 1 0 1 0 1 0 1 pf Pa 39 40 46 50 60 77 90 100 t 10 C Pa 800 1500 2200 3000 3900 11500 12500 14000 t 20 C Pa 300 400 550 600 700 10000 11000 12000 N 6 7 8 9 10 11 12 13 kg 340 383 425 467 510...

Страница 18: ...23 7 4 5 kgm 50 NM 8 1 1 4 15 30 28 16 2 12 2 1 35 12x1300 20 36 12x1070 18 D 2 20 18 M12x130 23 11 12 13 11 12 3 20 18 13 29 14 13 4 6 7 27 n 4 6 n 2 7 7 5 21 3 2 12 13 14 15 16 17 18 19 1 57 2 24 2...

Страница 19: ...16 17 18 fig 3 5 R 51 50...

Страница 20: ...NTG 98 46 711852 Control panel support 711328 Tie rod M16x1090 GIEGA NTG 114 47 Thermometer 711329 Tie rod M16x1210 GIEGA NTG 132 50 Regulation thermostat 711330 Tie rod M16x1330 GIEGA NTG 150 51 ON...