background image

 

Manual

 

 according to regulation DIN 82079

 

Version 09.19 

Date: 02.09.2019 

Name: Manual_VARIO-PA

 

 

GIEBEL FilTec GmbH • We

www.giebel-adsorber.de

 

 Email 

[email protected]

 

 Tel +49 (0) 7946 944401-0 

 

5/8 

Section 8: disposal 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

regeneration

 

In practice, the most common regeneration method used is temperature increase. When desorbing water 
vapour from silica gel, the temperature shall be above 100°C. A regeneration temperature between 
150°C and 175°C is recommended. However, it should be noted that a color indicator applied to the 
silica gel will be damaged at these temperatures. Therefore a regeneration temperature of 120°C is 
indicated for silica gel with colour indicator and should not exceed 140°C.

 

 

disposal 

At the end of its useful life, the device must be disposed of in accordance with the relevant legal 
regulations. Metal and plastic parts should be separated according to type and disposed of. The loaded 
drying agent Silicagel Orange can be disposed of in household waste. Silicagel Orange is not classified 
as a hazardous substance according to European Union legislation (Regulation EC No. 1272/2008). 
According to the EC Directive (67/548/EEC or 1999/45/EC) it is not subject to labelling. Silicagel Orange 
is not a hazardous substance for health or the environment. 

The desiccant Silicagel Blue is mixed with cobalt(II) chloride hexahydrate and is classified as a 
substance requiring labelling according to the EC Directive (1999/45/EC). This desiccant is one of the 
substances hazardous to health and the environment. National regulations must be observed for 
disposal.  
 

New / 

Regenerated 

Disposal / 

Regeneration 

Observe color changeOrange 

 - Colorless 

New / 

Regenerated 

Disposal / 

Regeneration 

Observe color changeBlue 

 - Pink 

Observe colour changeOrange 

 - Green 

Disposal / 

Regeneration 

New / 

Regenerated 

Содержание DV 300-PA

Страница 1: ...iss Str 5 DE 74626 Bretzfeld Schwabbach Phone 49 0 7946 944401 0 Fax 49 0 7946 944401 29 E mail info giebel adsorber de Section 2 Adsorber overview DV 300 PA DV 320 PA DV 500 PA DV 520 PA DV 550 PA DV 310 PA DV 330 PA DV 510 PA DV 530 PA DV 560 PA Materials used Acrylic glass aluminium acrylonitrile butadiene rubber NBR activated carbon moulded carbon Silica gel amorphous silicon dioxide REACH not...

Страница 2: ...ture 30 C 70 C Mounting part PA receiving part DV 3 MA DV 5 MA connection customs housing material Aluminium seal material NBR FKM Section 4 Technical Data VARIO PA D DV 300 PA DV 320 PA DV 500 PA DV 520 PA DV 550 PA Total weight kg 2 2 3 0 4 4 5 8 7 2 Adsorbent kg 0 8 1 3 2 2 3 3 4 5 Height mm 300 400 335 435 535 Housing diameter mm 110 110 150 150 150 Insertion diameter mm 140 140 180 180 180 co...

Страница 3: ...move the adsorber part by opening the closing clamps 3 Open the cover and remove it from the adsorber part 4 Remove the seal in the cover and replace it with a new one 5 Remove the activated charcoal disc and empty the desiccant 6 Pull out the dust filter insert 7 Remove the lower foam disk as well 8 Insert new foam disk 9 Insert a new dust filter insert and then Fill with fresh desiccant When fil...

Страница 4: ... package DV 563 PA Silicagel Orange Green 4kg Order of spare parts For constant operational readiness of the adsorber and thus of the hydraulic unit or transmission make sure that there is always a spare parts package or a spare adsorber part in stock The time to complete saturation of the activated carbon by the adsorption of oil mist and thus also the service life of the adsorber depends on vari...

Страница 5: ...elevant legal regulations Metal and plastic parts should be separated according to type and disposed of The loaded drying agent Silicagel Orange can be disposed of in household waste Silicagel Orange is not classified as a hazardous substance according to European Union legislation Regulation EC No 1272 2008 According to the EC Directive 67 548 EEC or 1999 45 EC it is not subject to labelling Sili...

Страница 6: ...lows into the system 2 1Porous seals Moist air can flow into the adsorber at the porous points This means that complete drying is not possible and moist air enters the system See maintenance plan point 4 2 2Saturated desiccant If the desiccant is saturated it cannot absorb any more moisture This allows moist air to enter the system See maintenance plan point 1 2 3Air flow rate too high If the air ...

Страница 7: ...nit for impurities Check Remove the lid from the adsorber part and remove the activated charcoal disc Then empty the desiccant The filter unit can then be removed This must be checked for impurities and should be free of dirt for smooth operation Action The filter unit is part of the spare parts package and should be replaced if there is contamination Proceed as described in Part 6 Maintenance Hal...

Страница 8: ...e If the valves do not open and close replace the valve part with a new one to ensure full functionality Biennial 6 Optical control of the adsorber Check The adsorber valve part and adsorber part must be visually checked for damage Damage can occur due to various environmental or operating conditions Action If the adsorber is damaged replace the damaged part to ensure full functionality Weekly 7 R...

Отзывы: