Assembly and commissioning 
 

Proceed as follows to install the entire adsorber:  

1.  Switch off the system. 
2.  Screw the valve part onto the plant. 
3.  Place the O-ring in the groove provided in the valve section and check that it is seated 

correctly. 

4.  Remove the safety plug from the valve part. 
5.  Peel off the protective foil on the underside of the adsorber part. 
6.  Push the adsorber part onto the sleeve of the valve part. 
7.  Hook the tensioning bracket into the closing hooks and push the tensioning levers 

downwards. 

8.  Secure the clamp with the safety plugs

 

 

Section 6: 

maintenance 
 

Procedure for reusable adsorbers 

1.  Switch off the system.  
2.  Remove the adsorber part by opening the closing clamps. 
3.  Open the cover and remove it from the adsorber part. 
4.  Remove the seal in the cover and replace it with a new one. 
5.  Remove the activated charcoal disc and empty the desiccant. 
6.  Pull out the dust filter insert. 
7.  Remove the lower foam disk as well. 
8.  Insert new foam disk. 
9.  Insert a new dust filter insert and then 

Fill with fresh desiccant. When filling the  
Using a soft object (e.g. ball of the hand), lightly knock the desiccant against 
the housing to compact the filling. 

10. Insert a new activated carbon disc and then close the lid again. 
11. Replace O-rings between valve part and adsorber part. 
12. If necessary, clean the lower foam disk with compressed air. 
13. Place the adsorber section back on the valve section and remove the  

Close the clamps. 

 

Procedure for disposable adsorbers 

1.  Switch off the system.  
2.  Remove the adsorber part by opening the  

Closure clamps. 

3.  New O-ring between valve section and adsorber section  

in. 

4.  Place the new adsorber part on the valve part and  

Close the clamps. 

 

Содержание DV 300-PA

Страница 1: ...iss Str 5 DE 74626 Bretzfeld Schwabbach Phone 49 0 7946 944401 0 Fax 49 0 7946 944401 29 E mail info giebel adsorber de Section 2 Adsorber overview DV 300 PA DV 320 PA DV 500 PA DV 520 PA DV 550 PA DV 310 PA DV 330 PA DV 510 PA DV 530 PA DV 560 PA Materials used Acrylic glass aluminium acrylonitrile butadiene rubber NBR activated carbon moulded carbon Silica gel amorphous silicon dioxide REACH not...

Страница 2: ...ture 30 C 70 C Mounting part PA receiving part DV 3 MA DV 5 MA connection customs housing material Aluminium seal material NBR FKM Section 4 Technical Data VARIO PA D DV 300 PA DV 320 PA DV 500 PA DV 520 PA DV 550 PA Total weight kg 2 2 3 0 4 4 5 8 7 2 Adsorbent kg 0 8 1 3 2 2 3 3 4 5 Height mm 300 400 335 435 535 Housing diameter mm 110 110 150 150 150 Insertion diameter mm 140 140 180 180 180 co...

Страница 3: ...move the adsorber part by opening the closing clamps 3 Open the cover and remove it from the adsorber part 4 Remove the seal in the cover and replace it with a new one 5 Remove the activated charcoal disc and empty the desiccant 6 Pull out the dust filter insert 7 Remove the lower foam disk as well 8 Insert new foam disk 9 Insert a new dust filter insert and then Fill with fresh desiccant When fil...

Страница 4: ... package DV 563 PA Silicagel Orange Green 4kg Order of spare parts For constant operational readiness of the adsorber and thus of the hydraulic unit or transmission make sure that there is always a spare parts package or a spare adsorber part in stock The time to complete saturation of the activated carbon by the adsorption of oil mist and thus also the service life of the adsorber depends on vari...

Страница 5: ...elevant legal regulations Metal and plastic parts should be separated according to type and disposed of The loaded drying agent Silicagel Orange can be disposed of in household waste Silicagel Orange is not classified as a hazardous substance according to European Union legislation Regulation EC No 1272 2008 According to the EC Directive 67 548 EEC or 1999 45 EC it is not subject to labelling Sili...

Страница 6: ...lows into the system 2 1Porous seals Moist air can flow into the adsorber at the porous points This means that complete drying is not possible and moist air enters the system See maintenance plan point 4 2 2Saturated desiccant If the desiccant is saturated it cannot absorb any more moisture This allows moist air to enter the system See maintenance plan point 1 2 3Air flow rate too high If the air ...

Страница 7: ...nit for impurities Check Remove the lid from the adsorber part and remove the activated charcoal disc Then empty the desiccant The filter unit can then be removed This must be checked for impurities and should be free of dirt for smooth operation Action The filter unit is part of the spare parts package and should be replaced if there is contamination Proceed as described in Part 6 Maintenance Hal...

Страница 8: ...e If the valves do not open and close replace the valve part with a new one to ensure full functionality Biennial 6 Optical control of the adsorber Check The adsorber valve part and adsorber part must be visually checked for damage Damage can occur due to various environmental or operating conditions Action If the adsorber is damaged replace the damaged part to ensure full functionality Weekly 7 R...