2 TECHNICAL DATA
TOP 291E - 291ER - 291ER/S
-
To lay the cables use appropiate cable ducts.
It is good practice to separate the power cables from the accessory connection cables and it is therefore
advisable la to use at least two tubes to run the cables through.
WARNING:
It is important to fit an omnipolar magnetothermal /difeerential switch with a min. contact opening of 3 mm on the
power line upstream of the control unit.
OPERATOR
Operating frequency (%Fu) at 20°C
Electric motor
Capacitor
Maximum thrust
Hydraulic slowdown
Rod maximum stroke
Operating temperature
Leaf maximum lenght
Hydraulic lock granted for leaf
maximum lenght
Power absorbed
Protection degree
Thrust adjustment
Rod speed
Hydraulic oil
Thermal protection
Formula to calculate the operation
frequency
TOP 291E
TOP 291ER
[
]
55%
2a
230 Vac 1450 rpm
max 170 W
10
μF
IP65
hydraulic
GBD PH-03
[
]
3.5 m
2c
2.0 m
100°C
from -20°C to +60°C
2000 N
20 mm/s
yes
265 mm
3000 N
10 mm/s
no
290 mm
TOP 291ER/S
A = Opening time
C = Closing time
P = Overall pause time
A+C+P = Time between two
openings
%Fu =
x 100
A + C
A + C + P
WARNINGS FOR THE USER
In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service.
Periodically check the good functioning of the safety devices.
Any repair must be carried out by specialised personnel using original and certified materials.
The product must not be used by children and persons with reduces physical, sensorial or mental capacities, or
without experience and knowledge.
Do no access the control unit for adjustments and/or maintenances.
WARNING: IMPORTANT SAFETY INSTRUCTIONS
It is important to follow this instruction to safeguard persons.
Keep this instruction manual.
1 - ELECTRICAL CONNECTIONS
[ ]
Set up the electric system as shown in fig.
1
referring to the electric system regulations and other
national regulations in force. Keeps the mains power connection clearly separated from
service connections (photocells, sensitive edge, control units etc.).
The main components of the automated device are:
À
Flashing light: 0.75 mm² 2-core (2x0,75) cable.
Á
Antenna: screened coaxial cable.
Â
Key selector: 0,5 mm² 3-core (3x0,5) cable.
Ã
Photocell receiver: 0,5 mm² 4-core (4x0,5) cable.
Ä
Photocell transmitter: 0,5 mm² 2-core (2x0,5) cable.
Å
Omnipolar magnetothermal differential switch with min. contact opening of 3 mm.
220-230Vac 50-60Hz power line to the device: 1,5 mm² min. 3-core (3x1,5) cable (adhere to the regulations
in force).
Æ
Case for electronic control unit: 3x1,5 mm² cable.
Ç
230Vac operator
:
Power supply: 1,5 mm² 4-core cable:
Grey = motor common; Brown = opening; Black = closing; Yellow/green = earth
È
8K2 sensitive edge: 0,5 mm² 2-core (2x0,5) cable.
Electronic lock: 1,5 mm² 2-core (2x1,5) cable.
Mechanical stops in opening and closing.
0
Содержание TOP EVO 291E/S
Страница 5: ...5 TOP EVO 100 120 B A 100 150 150 150 B A 20 mm 5 6 7...
Страница 7: ...7 TOP EVO 1 2 3 5 2 3 4 10 11...
Страница 8: ...1 PRESSURE ADJUST REGOLAZIONE PRESSIONE OPEN APRE CLOSE CHIUDE 2 3 4 1 3 3 4 12 13 8 TOP EVO...
Страница 9: ...9 TOP EVO 3 4 5 6 2 1 5 3 4 7 7 4 3 1 5 2 6 14a 14b...
Страница 58: ...58 TOP EVO NOTE NOTES NOTES NOTAS...
Страница 59: ...59 TOP EVO NOTE NOTES NOTES NOTAS...