Consideration of care for your water heater should  
include evaluation of water quality.   

Water that contains chemicals exceeding the levels 
below affect and damage the heat exchanger.  
Replacement of the heat exchanger due to water 
quality damage is not covered by the warranty. 

 

Maximum Level 

Total Hardness 

Up to 200 mg / L 

Aluminum * 

Up to 0.2 mg / L 

Chlorides * 

Up to 250 mg / L 

Copper * 

Up to 1.0 mg / L 

Iron * 

Up to 0.3 mg / L 

Manganese * 

Up to 0.05 mg / L 

pH * 

6.5 to 8.5 

TDS (Total Dissolved Solids) * 

Up to 500 mg / L 

Zinc * 

Up to 5 mg / L 

Determine Installation Location 

Environment 

Air surrounding the water heater, venting, and vent 
termination(s) is used for combustion and must be 
free of any compounds that cause corrosion of 
internal components.  These include corrosive 
compounds that are found in aerosol sprays, 
detergents, bleaches, cleaning solvents, oil based 
paints/ varnishes, and refrigerants.  The air in beauty 
shops, dry cleaning stores, photo processing labs, and 
storage areas for pool supplies often contains these 
compounds.   

The water heater, venting, and vent termination(s)  
should not be installed in any areas where the air may 
contain these corrosive compounds.  If it is necessary 
for a water heater to be located in areas which may 
contain corrosive compounds, the following 
instructions are strongly recommended. 

IMPORTANT CONSIDERATIONS FOR: 

  Indoor/Internal Water Heaters and Vent 

Terminations of Indoor/Internal Water Heaters 

 

DO NOT Install in areas where air for combustion 
can be contaminated with chemicals. 

 

Before installation, consider where air has the 
ability to travel within the building to the water 
heater. 

 

Where possible, install the water heater in a 
sealed closet so that it is protected from the 
potential of contaminated indoor air. 

 

Chemicals that are corrosive in nature should not 
be stored or used near the water heater. 

 

Install the water heater termination as far away 
as possible from exhaust vent hoods. 

 

Install the water heater termination as far away 
as possible from air inlet vents.  Corrosive fumes 
may be released through these vents when air is 
not being brought in through them. 

 

Chemicals that are corrosive in nature should not 
be stored or used near the water heater or vent 
termination. 

Damage and repair due to corrosive compounds in 
the air is not covered by warranty. 

Water Quality 

* Source: Part 143 National Secondary Drinking Water 
Regulations 

If you install this water heater in an area that is 
known to have hard water or that causes scale build-
up the water must be treated and/or the heat 
exchanger flushed regularly. 
When scale build-up in the heat exchanger begins to 
affect the performance of the water heater, a 
diagnostic code “LC#” will display.  Flush the heat 
exchanger to prevent damage to it.  Scale build up is 
caused by hard water set at a high temperature.   

You must ensure that clearances will be met and that 
the vent length will be within required limits.  
Consider the installation environment, water quality, 
and need for freeze protection.  Requirements for the 
gas line, water lines, electrical connection, and 
condensate disposal can be found in their respective 
installation sections of this manual. 

Содержание UGTC-152N

Страница 1: ...ot touch any electrical switch do not use any phone in your building If you cannot reach your gas supplier call the fire department may result causing property damage personal injury or death WARNING...

Страница 2: ...titude U S 20 Adjust for High Altitude Canada 20 Adjust for Vent Length 21 Checklist for Gas and Electricity 21 Installation of Temperature Controller 21 Final Checklist 23 Technical Data 24 Specifica...

Страница 3: ...as appliance Always check the water temperature before entering a shower or bath To protect yourself from harm before performing maintenance Turn off the electrical power supply by unplugging the powe...

Страница 4: ...such locations cannot be avoided it is recommended that a suitable drain pan adequately drained be installed under the appliance The pan must not restrict combustion air flow Do not obstruct the flow...

Страница 5: ...emicals such as chlorine or bleach that produce fumes These fumes can damage components and reduce the life of your appliance Tankless water heater MC 91 2 temperature controller integrated into the f...

Страница 6: ...mbustion can be contaminated with chemicals Before installation consider where air has the ability to travel within the building to the water heater Where possible install the water heater in a sealed...

Страница 7: ...ription Canadian Installations US Installations A Clearance above grade veranda porch deck or balcony 12 inches 30 cm 12 inches 30 cm B Clearance to window or door that may be opened 36 inches 91 cm 1...

Страница 8: ...r crawl space vents or other area where condensate or vapor could create a nuisance or hazard or cause property damage or Where condensate or vapor could cause damage or could be detrimental to the op...

Страница 9: ...ause of the wind chill effect any wind or circulation of the air on the unit will reduce its ability to freeze protect The unit may be drained manually However it is highly recommended that drain down...

Страница 10: ...m 2 29 ft 8 8 m 3 23 ft 7 0 m 4 17 ft 5 2 m 5 11 ft 3 4 m 6 5 ft 1 5 m If you have a longer vent length see above switch No 1 is required to be in the OFF position This ensures the water heater will r...

Страница 11: ...he water heater is not exposed to corrosive compounds in the air The water heater location complies with the clearances The planned venting will not exceed the maximum length for the number of elbows...

Страница 12: ...with a minimum number of pipe fittings Vent connections must be firmly pressed together so that the gaskets form an air tight seal The vent piece connected to the water heater must be secured with one...

Страница 13: ...er heater with one self tapping screw at the hole Horizontal Termination Securing Screw Vertical Termination Slope the venting toward the appliance according to the vent manufacturers installation ins...

Страница 14: ...ng The vent termination and air intake must be in the same pressure zone Do not exceed maximum straight vent length with number of elbows as shown in the tables on the next page Maintain the clearance...

Страница 15: ...d the vents and air intakes Ensure you have used the correct venting products for the model installed and that you have completely followed the venting manufacturer s installation instructions and the...

Страница 16: ...s and Automatic Gas Shutoff Devices for Hot Water Supply Systems ANSI Z21 22 and or the standard Temperature Pressure Temperature and Pressure Relief Valves and Vacuum Relief Valves CAN1 4 4 The relie...

Страница 17: ...ndensate section in the venting instructions Water drain plug Condensate trap drain plug Condensate drain line Gas connection Cold water inlet Hot water outlet The condensate drain pipe along its enti...

Страница 18: ...iant recommends 60 80 psi for maximum performance Installation of Gas Supply MUST DO A manual gas control valve must be placed in the gas supply line to the water heater A union can be used on the con...

Страница 19: ...t then the 3 4 inch pipe size is capable of supplying 264 FT3 HR of natural gas Gas Input of all gas products BTU HR Heating Value of Gas BTU FT 3 Cubic Feet per Hour CFH Any compound used on the thre...

Страница 20: ...shown in table below for your altitude The default setting for the appliance is 0 2000 ft 0 610 m with switches No 2 and No 3 in the OFF position When the DIP switch is adjusted it is not necessary t...

Страница 21: ...ired Controllers Maximum Cable Length for each Controller to Water Heater 1 328 ft 100 m 2 164 ft 50 m 3 65 ft 20 m Turn the power off Do not attempt to connect the temperature controllers with the po...

Страница 22: ...oller terminals on the right hand side bottom of the PCB 9 Secure the controller cable using the clamp provided 10 Replace plastic cover over PCB and then replace the cover of the water heater Outline...

Страница 23: ...bottom of the water heater to catch any water that is contained inside the unit Unscrew the water filter Rinse the filter to remove any debris Install the filter and open the isolation valves Check th...

Страница 24: ...8 F 37 C Weight 61 7 lb 28 kg Energy Factor 0 96 0 95 Noise level 41 dB Normal 42 W 64 W Electrical Data Standby 2 W Anti frost Protection 146 W Max Current Without recirculation pump 4 A With recircu...

Страница 25: ...40 mm DIMENSION Inches mm A GAS 1 6 40 2 A COLD 2 0 50 2 A HOT 1 6 41 2 A CONDENSATE OUTLET 0 9 22 4 B 5 0 127 2 C 1 9 47 8 D 0 52 13 3 E 2 2 56 3 F 2 3 58 3 G 5 0 127 2 H 2 0 50 I 3 0 76 J 7 1 179 K...

Страница 26: ...p Curve Outlet Flow Data Water Flow gpm delta T Temperature Rise F Pressure Loss ft head Water Flow gpm Pressure Loss psi The chart below only applies to incoming water temperatures of 70 F 21 C or le...

Страница 27: ...UGTC Series Manual 27 Ladder Diagram...

Страница 28: ...return line according to the pump manufacturer installation instructions Install a check valve in the return line as shown in the Plumbing Diagram if one is not integrated into the pump 3 The wire ha...

Страница 29: ...ased on the temperature thermistor readings Economy Mode The Economy mode operates as follows Less energy consumed due to fewer pump cycles Assumes plumbing is insulated minimal pipe heat loss Pump cy...

Страница 30: ...ses please contact customer service and ask not to have your information shared We will however continue to contact you with information relevant to the product s you registered and or you account wit...

Страница 31: ...TURN OFF GAS TO APPLIANCE 1 Turn off all electric power to the appliance using the ON OFF button 2 Set the thermostat to lowest setting 3 Locate the manual gas valve on the side of the heater Turn the...

Страница 32: ...e floor Keep the area around the appliance clear and free from combustible materials gasoline and other flammable vapors and liquids Always check the water temperature before entering a shower or bath...

Страница 33: ...ing All hot water sources are able to provide water at this temperature setting until it is changed again at this or another temperature controller DANGER Hot water can be dangerous especially for inf...

Страница 34: ...115 120 125 130 135 140 150 160 185 Celsius C 37 38 39 40 41 42 43 46 49 52 54 57 60 66 71 85 These settings require the MCC 91 2 controller When the MCC 91 2 controller is connected these higher temp...

Страница 35: ...before To enter or exit the maintenance monitor information mode press and hold the down button for 2 seconds and without releasing it press the ON OFF button To obtain the water flow rate press the...

Страница 36: ...ion collar was installed properly Ensure vent length is within limits Verify dip switches are set properly Check power supply for loose connections Check power supply for proper voltage and voltage dr...

Страница 37: ...o flame rod Remove flame rod and check for carbon build up clean with sand paper Check inside burner chamber for any foreign material blocking flame at flame rod Measure micro amp output of sensor cir...

Страница 38: ...eeds to be treated or conditioned When checking maintenance code history 00 is substituted for LC Snow Accumulation Keep the area around flue terminal free of snow and ice The appliance will not funct...

Страница 39: ...ny issues resulting from the use of this information GAS Shut off the gas to the water heater It is generally preferable to shut off the gas service to the entire location if gas is not going to be us...

Страница 40: ...ted virgin food grade white vinegar into pail 6 Place the drain hose H3 and the hose H2 to the pump inlet into the cleaning solution 7 Open both service valves V1 and V2 on the hot water and cold wate...

Страница 41: ...ON 0 1 gal min or about 0 2 inch thick To avoid burns wait until the equipment cools down before draining the water The water in the appliance will remain hot after it is turned off WARNING To manual...

Страница 42: ...vices of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a In the event that the side wall horizontally vented gas fueled equipment is installed in a craw...

Страница 43: ...water heater This Limited Warranty coverage as set out in the table below extends to the original purchaser and subsequent owners but only while the product remains at the site of the original install...

Страница 44: ...nstalled adjacent to a free flowing drain in the event of water leakage 8 If the heater is operated at water temperatures exceeding the maximum setting of the operating and or high limit con trol or t...

Страница 45: ...hom the water heater was purchased is essential to settle any warranty claim dispute over the length of the period of installation If an exact replacement is not available a current model water heater...

Страница 46: ...Notes Maintenance Information...

Отзывы: