UGTC Series Manual
21
Installation of Temperature Controller
Controller Location
Cable Lengths and Sizes
The controller should be out of reach of small
children.
Avoid locations where the controller may become
hot (near the oven or radiant heater).
Avoid locations in direct sunlight. The digital
display may be difficult to read in direct sunlight.
Avoid locations where the temperature controller
could be splashed with liquids.
Do not install in locations where it can be
adjusted by the public.
Models have their controller built into the front
panel. Additional controllers can be installed.
The cable for the temperature controller should be a
non-polarized two-core cable with a minimum gauge
of 22 AWG. The maximum cable length from each
controller to the water heater depends on the total
number of wired controllers connected to the water
heater.
Number of Wired
Controllers
Maximum Cable Length for each
Controller to Water Heater
1
328 ft (100 m)
2
164 ft (50 m)
3
65 ft (20 m)
Turn the power off. Do not attempt to connect the
temperature controllers with the power on. Although
the controller is a low voltage device, there is 120 volt
potential next to the temperature controller
connections inside the unit.
Do not connect the temperature controller to the
120VAC terminals provided for the optional solenoid
drain valves.
WARNING
Checklist for Gas and Electricity
□
A manual gas control valve is placed in the gas
line to the water heater.
□
Check the gas lines and connections for leaks.
□
Confirm that the gas inlet pressure is within
limits.
□
Confirm that the water heater is rated for the gas
type supplied.
□
Confirm that the electricity is supplied from 120
VAC, 60 Hz power source and is in a properly
grounded circuit.
□
An extension cord or an adapter plug has not
been used with the water heater.
Adjust for Vent Length
Adjust switch No. 1 in the SW1 DIP switch (tan
switches) if required. Refer to the section “Maximum
vent length”.
Содержание UGTC-152N
Страница 27: ...UGTC Series Manual 27 Ladder Diagram...
Страница 46: ...Notes Maintenance Information...