background image

26

GENERAL

The manufacturer warrants that, subject to verification of a warranty 

claim within the warranty period as described below, it will take the 

necessary corrective action to either repair or replace a water heater 

or component part which is determined to be defective in material 

or workmanship subject to the terms and conditions outlined in this 

document. Further, any replacement water heater or component part 

supplied under warranty will carry only the unexpired portion of the 

original water heater’s warranty. The number of replacement water 

heaters is limited to one (1) per original unit purchased. If due to 

some extremely unusual circumstance, a replacement water heater 

or component part is found by our inspection & testing department 

to be defective, another heater or component part will be supplied to 

fulfill the obligation of the warranty of the original heater.

THE INNER TANK

If the inner tank fails within SIX (6)* years after the date of the 

original installation, a replacement water heater will be provided to 

the party from whom the unit was originally purchased. If the water 

heater is installed in other than a single family dwelling, the tank 

warranty is limited to ONE (1) year. If an exact replacement is not 

available, the manufacturer reserves the right to furnish a compa-

rable model water heater; however, a surcharge will be applied for 

any additional component(s) incorporated in the replacement water 

heater. The warranty reply card must be completed and sent back to 

the manufacturer within forty-five (45) days of the installation date. If 

said warranty card is not returned, the date indicated on the model 

serial plate will prevail. 

COMPONENT PARTS

If any component part is found to be defective within ONE (1)* year 

from the date of original installation, provided said defective part is 

an in-house factory made piece or an original factory approved OEM 

piece, the manufacturer will furnish a replacement part after the 

receipt and testing of the part claimed to be defective. 

THIS WARRANTY WILL NOT APPLY

1) 

To defects or malfunctions resulting from failure to properly 

install, operate, or maintain the unit in accordance with the print-

ed instructions.

2) 

If the installation does not conform to CSA &/or ETL Standards 

as well as any applicable national or local building codes.

3) 

To any damage or failure caused by abuse, accident, fire, floods, 

freezing, or other acts of God.

4) 

To any damage or failure caused by operating the heater without 

an approved pressure & temperature relief valve having been 

installed.

5) 

To any damage or failure caused by operating the heater with an 

empty or partially empty inner tank or sediment build-up result-

ing in dry firing of the heating elements.

6) 

To any damage or failure caused by utilizing the heater in con-

junction with any other energy saving device or other source(s) 

of energy not approved by the manufacturer; or for other than 

use with potable water without any additives such as salt, chlo-

rine, or chemicals other than those added for the purpose of 

rendering the water fit to drink.

7) 

To any damage or failure caused by the removal of the anode 

&/or by not assuring that there is a working anode in the tank at 

all times. All anodes must be checked at least once every two 

years & replaced if necessary

8) 

To any damages or failure caused by having affixed to the 

heater any non-factory made or factory approved replacement 

part(s) such as elements, controls, dip-tubes, relief valves, etc...

9) 

To any damage caused by not having the water heater installed 

adjacent to a free flowing drain in the event of water leakage. 

10) 

If the heater is operated at water temperatures exceeding the 

maximum setting of the operating &/or high limit control or the 

heater is not supplied with potable water, free to circulate at all 

times.

11) 

If the heater has experienced the effect of thermal expansion 

due to excessive pressure (exceeding 300PSI). The result of 

excessive pressure usually reverses the bottom of the inner tank 

and can occur with the addition of a pressure reducing valve &/

or a check valve in the municipal water supply system in a single 

family dwelling.

12) 

If the heater is installed outside of Canada.

SERVICE LABOUR RESPONSIBILITY

This warranty does not cover any labour expense for service, remov-

al, or re-installation of a replacement heater. All such expenses are 

your responsibility.

SHIPPING COSTS

If a water heater or component part is deemed to be replaced, the 

manufacturer will pay the transportation costs of the replacement 

unit to a convenient authorized distributor or retailer as selected by 

us. You must pay any local cartage including the cost of returning 

the replaced item to the authorized distributor or retailer from whom 

the replacement is coming from.

HOW TO MAKE A CLAIM

Any claim for warranty service should be made to your contractor, 

wholesaler, or retailer from whom the water heater was purchased. 

In turn, said contractor, wholesaler, or retailer will contact the manu-

facturer from whom they purchased the heater. If this procedure 

cannot be followed, contact any other local contractor, wholesaler, 

or retailer handling our water heaters. Also, for warranty information 

you may call the manufacturer’s customer service department at 

(514) 645-8893 or 1-800-363-9354, option 1. We suggest that prior 

to calling the factory, that you make sure to have the model number 

& serial number that is to be found on the outside casing of the 

heater. Proof of purchase showing the date, name, and place of the 

business from whom the water heater was purchased is essential 

to settle any warranty claim dispute over the length of the period 

of installation.

If an exact replacement is not available, a current model water 

heater or component part with comparable operating features will be 

provided by the manufacturer. If government regulations or industry 

standards require the replacement model water heater or compo-

nent part to have features not found on the defective model water 

heater or component part, you will be charged the difference in price 

associated with these required features. If you pay the difference in 

price for these required features, you will receive a complete new 

Standard Basic Limited Warranty for the replacement water heater.

MISCELLANEOUS

No one is authorized to make any other warranties on the manu-

facturer’s behalf. Any implied warranties of any nature offered 

by a third party other than what is stated in this Standard Basic 

Limited Warranty will not be honoured. No claims for incidental or 

consequential damages (including damages from leakage) will be 

accepted.  If you do not return the warranty card, a proof of pur-

chase showing the name, date, and location of the original source 

of purchase is a necessity to process a warranty claim. Failure to 

produce this documentation will result in the lesser or the warranty 

periods being offered. In order to avoid any confusion &/or disputes, 

we suggest that the warranty card be completed and mailed back no 

later than forty-five (45) days after installation.

*EXTENDED WARRANTIES

For information on some premium quality residential gas & electric 

water heaters, contact your local licensed plumber, or look for them 

at selected retailers.

STANDARD BASIC LIMITED WARRANTY

ON RESIDENTIAL GAS WATER HEATERS

THIS WARRANTY IS VALID FOR CANADIAN INSTALLATIONS ONLY

Содержание UG50 series

Страница 1: ...quids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your building From a neigh...

Страница 2: ...er inspected immediately by a qualified service technician or the gas supplier WARNING Safety Information 3 Installation Instructions 4 Altitude 4 Location 4 Minimum Clearances 4 Venting 4 Venting Con...

Страница 3: ...This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING Serious injury or death c...

Страница 4: ...vered by the panel Minimum Clearances The minimum clearances from combustible material for this water heater are Two 2 inches 5 1 cm from the sides and rear four 4 inches 10 2 cm from the front and ei...

Страница 5: ...d States see Figure 4 This water heater must be vented directly to the outdoors either horizontally through the wall or vertically through the roof The venting must not be attached to an existing chim...

Страница 6: ...2 X 3 is necessary for a three 3 inch 7 6 cm venting system This coupling must be installed as close as possible after the rubber transition fitting and in every case before the first elbow Vent Syste...

Страница 7: ...orch deck or balcony 12 inches 30 cm 12 inches 30 cm B Clearance to window or door that may be opened 12 inches 30 cm 9 inches 23 cm or 12 inches 30 cm C Clearance to outside corner D Clearance to ins...

Страница 8: ...or wall same atmospheric pressure zone The air intake equivalent vent length must be equal to or less than the exhaust equivalent vent length and the air intake termination elbow shall be equipped wit...

Страница 9: ...ke terminal must be at a minimum of eighteen 18 inches 45 7 cm from the exterior surface of the roof or anticipated snow accumulation level see Figure 2 The vertical terminations should be sealed with...

Страница 10: ...ssemble parts while cement is fluid If you wait too long re coat pipe fitting 8 Push the vent pipe completely into the coupling turning as it goes until it bottoms out 9 Hold pipe and fitting together...

Страница 11: ...ent system from IPEX be sure to install the two 2 inch 5 1 cm black restrictor screen from 0 to twenty five 25 feet 7 6 m If using the three 3 inch 7 6 cm concentric vent system from IPEX be sure to i...

Страница 12: ...an result in property damage personal injury or death To protect from excessive pressure and or temperature the manufacturer has installed a temperature and pressure relief valve that meets the requir...

Страница 13: ...roved for natural and propane gases It is mandatory that a readily accessible manual shut off valve be installed in the gas supply line The gas supply manual shut off valve must be close to the water...

Страница 14: ...1o F 105o C Installation Instructions for Water Heaters Approved for Combination Space Heating and Potable Water Heating see Figure 11 A water heater cannot be used for space heating only When using a...

Страница 15: ...er is equipped with a check valve water meter or pressure reducing valve an expansion tank must be installed in the system This will prevent weeping from the water heater relief valve and premature fa...

Страница 16: ...he appropriate primer and solvent based cement when necessary Has the venting been supported at the proper intervals Have precautions been taken against condensation flowing into the power venter Wate...

Страница 17: ...ter immediately contact a qualified installer service agency or the gas sup plier WARNING DO NOT light this water heater if It is not full of water The gas supplied does not match the type listed on t...

Страница 18: ...he COOLER button until you have reached the desired setting HOLDING DOWN THE BUTTON WILL NOT CONTINUE TO LOWER THE SETTING The button must be pressed and released for each tempera ture change desired...

Страница 19: ...switch to lock out mode and prevent the water heater from lighting After a flammable vapour incident has occurred and the flam mable vapours have dissipated the FV sensor is designed to automatically...

Страница 20: ...common observation is hot water that smells like rotten eggs This phenomenon is the result of the reaction between the anode and hydrogen sulfide gas dissolved in the water which occurs frequently in...

Страница 21: ...listed in the Troubleshooting Guide does not solve the problem or if your particular problem is not listed in the guide contact the installer of the water heater or the local gas utility 3 If you sti...

Страница 22: ...r Access Doors 7 Outer Access Door 8 Drain Valve 9 Overflow Tube 10 Dip tube 11 Magnesium Anode 12 Temperature Pressure Relief Valve 13 Baffle 14 Inlet Rubber Adaptor 15 Vacuum Switch Inlet 16 Vacuum...

Страница 23: ...ion 5 Low voltage to the water heater Check and repair 7 The gas valve driver circuit 1 Turn off the power to the water heater for 10 seconds and then back on 2 If the above step did not clear the err...

Страница 24: ...re Check with gas utility company Defective gas control valve Replace with new gas control valve High operating costs Gas control valve set too high Turn temperature dial to desired temperature Sedime...

Страница 25: ...ter filled for first time Let water heater warm up Problem should go away If it per sists check all plumbing connections for leaks Heavy draws of hot water with very cold refill water Let water heater...

Страница 26: ...in in the event of water leakage 10 If the heater is operated at water temperatures exceeding the maximum setting of the operating or high limit control or the heater is not supplied with potable wate...

Страница 27: ...xed to the heater any non factory made or factory approved replace ment part s such as elements controls dip tubes relief valves etc 9 To any damage caused by not having the water heater installed adj...

Страница 28: ...___________________________________________________________ ________________________________________________________________________________ ___________________________________________________________...

Отзывы: