Table 3 — DuraVent™

Appliance 

adapter

Increaser

Appliance 

adapter clamp

3-inch (7.6 cm) pipe

2PPS-AD 2PPS-X3

PPS-PAC

Through-the-Wall Venting Installation

DANGER

WARNING

CAUTION

AVERTISSEMENT

ATTENTION

When installing the vent piping, make sure that the vent 

terminal is 

NEVER

 installed below the air intake terminal. 

The air intake terminal must always face downward. Failure 

to follow this instruction could result in property damage, 

personal injury, or death.

Two (2) vent terminal options are available to vent this water 

heater. The first is a standard 90-degree elbow facing down-

ward 

(see Figure 6a)

 and the second is the concentric vent 

termination kit 

(see Figure 6b)

.

Cut or drill two (2) holes through the exterior wall, slightly larger 

than the diameter of the vent pipe selected. The larger holes will 

allow for final alignment with the water heater. Extend a section 

of pipe through each hole to the outside and attach the terminat-

ing elbow to the exterior end of each pipe. The vent and air intake 

terminals must be at least eight (8) inches (20.3 cm) apart and 

the vent terminal must 

NEVER

 be installed below the air intake 

terminal for any reason 

(see Figure 6a)

. The air intake terminal 

and the vent terminal must terminate on the same exterior wall 

(same atmospheric pressure zone).

The air intake equivalent vent length must be equal to or less 

than the exhaust equivalent vent length and the air intake ter-

mination elbow shall be equipped with a standard wire mesh 

screen. 

IMPORTANT

Connect and secure all piping and elbows from the power venter 

to the wall. When the installation is completed, the vent and air 

intake terminals must be at two (2) inches (5.1 cm) from the 

exterior surface of the wall 

(see Figure 2)

. Do not extend vent 

or air intake piping past this length. Make sure that all piping is 

properly supported. If the venting will pass through an enclosed 

area, make sure to leave at least one (1) inch (2.5 cm) clearance 

around the piping for air circulation.

FOR PVC AND CPVC PIPING: 

PolyPro

®

InnoFlue

®

Make sure that all horizontal runs have a minimum rise of 1/4 

inch per foot (21 mm/m) of run 

(see Figure 7)

. Horizontal 

runs of vent pipe must be supported every three (3) feet (91 

cm).

FOR POLYPROPYLENE PIPE FROM CENTROTHERM 

(Innoflue single wall vent system): 

PolyPro

®

InnoFlue

®

Make sure that all horizontal runs have a minimum rise of 5/8 

inch per foot (56 mm/m) of run. Follow instruction of the vent 

pipe manufacturer for proper vent support.

FOR POLYPROPYLENE PIPE FROM DURAVENT 

(Polypro single wall gas vent system): 

PolyPro

®

InnoFlue

®

Make sure that all horizontal runs have a minimum rise of 1/4 

inch per foot (21 mm/m) of run. Follow instruction of the vent 

pipe manufacturer for proper vent support.

Concentric Vent Termination Kit Installation

A three (3) inch (7.6 cm) Concentric Vent Termination Kit (IPEX 

model 196006) may be used with a three (3) inch (7.6 cm) 

restrictor screen for side wall termination installations. Using 

this Concentric Vent Termination Kit will reduce the maximum 

allowable equivalent vent pipe length for both air intake and 

exhaust systems 

(see Table 1)

Figure 6b

 illustrates the 

Concentric Vent Termination Kit for side wall installation. See 

manufacturer’s instructions for complete installation details.

Through-the-Roof Venting Installation

Cut or drill two (2) holes through the roof and ceiling, slightly larg-

er than the diameter of the vent pipe selected. The larger holes will 

allow for final alignment with the water heater. Construct the vent 

terminal assembly. Extend a section of pipe through each hole in 

the roof to the outside and attach the terminal assembly to the 

exterior end of each pipe. The vent and air intake terminals must 

be at least eight (8) inches (20.3 cm) apart and the vent terminal 

INSTALLATION INSTRUCTIONS

Appliance adaptor

3” venting

3” venting

Increaser

Appliance adaptor

Vent System Adaptor

Appliance 

Adaptor Clamp

Increaser

Figure 4 

 — InnoFlue

® 

Centrotherm

Appliance adaptor

3” venting

3” venting

Increaser

Appliance adaptor

Vent System Adaptor

Appliance 

Adaptor Clamp

Increaser

Figure 5 

— PolyPro

® 

DuraVent

Содержание InnoFlue Centrotherm

Страница 1: ...or any other appliance WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your building From a neighbour s phone immediately call your gas supplier and EnerCare Home Services Follow their instructions If you cannot reach immediately the above suppliers call the fire department at 911 Installation and service must be performed on...

Страница 2: ...t nettoyant liquide Éviter les endroits humides et les températures sous le point de congélation Si le détecteur décèle la présence de vapeurs inflammables le contôle au gaz se vérouillera et le chauffe eau cessera de fonctionner Ne tentez pas de le remettre en marche Faite inspecter le chauffe eau immédiatement par un technicien de service qualifié ou le fournisseur de gaz ATTENTION Safety Inform...

Страница 3: ...ert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING Serious injury or death can occur if you do not fol low the instructions immediately Serious injury or death can occur if you do not fol low the instructions WARNING AVERTISSEMENT DANGER WARNING AVERTISSEMENT DANGE...

Страница 4: ...or this water heater are Two 2 inches 5 1 cm from the sides and rear four 4 inches 10 2 cm from the front and eighteen 18 inches 45 7 cm from the top see Figure 1 18 min 2 min 2 min 2 min 4 min Figure 1 Venting DANGER WARNING CAUTION AVERTISSEMENT ATTENTION When installing the venting system make sure to follow all local codes or in the absence of local codes the latest edition of CAN CSA B149 1 N...

Страница 5: ...1 NFPA 54 in the United States see Figure 3 This water heater must be vented directly to the outdoors either horizontally through the wall or vertically through the roof The venting must not be attached to an existing chimney or in com mon with any other appliance and must not be insulated If possible locate the water heater so that the venting length and number of elbows are kept to the minimum n...

Страница 6: ...6 INSTALLATION INSTRUCTIONS 2 18 min 3 min 8 max 18 min 8 min IN ANY DIRECTION 8 min See Figure 6A 90 INTAKE TERMINAL 18 min 90 INTAKE TERMINAL 18 min VENT TERMINAL Figure 2 ...

Страница 7: ...d within ten 10 feet 3 05 m The Vent Termination must have a Canadian Installations U S Installations A Clearance above grade veranda porch deck or balcony 12 inches 30 cm 12 inches 30 cm B Clearance to window or door that may be opened 12 inches 30 cm 9 inches 23 cm or 12 inches 30 cm C Clearance to outside corner D Clearance to inside corner 3 feet 91 cm E Clearance to service regulator vent out...

Страница 8: ...nce around the piping for air circulation FOR PVC AND CPVC PIPING PolyPro InnoFlue Make sure that all horizontal runs have a minimum rise of 1 4 inch per foot 21 mm m of run see Figure 7 Horizontal runs of vent pipe must be supported every three 3 feet 91 cm FOR POLYPROPYLENE PIPE FROM CENTROTHERM Innoflue single wall vent system PolyPro InnoFlue Make sure that all horizontal runs have a minimum r...

Страница 9: ... horizontal runs have a minimum rise of 5 8 inch per foot 56 mm m of run Follow instruction of the vent pipe manufacturer for proper vent support Clamp or Strap field supplied 1 2 5 cm Min 2 5 cm Max Exhaust Optional Elbow see local codes voir codes locaux Coude optionnel Exhaust Distance above average snowfall or grade reference CSA B149 1 Air intake Air intake Exterior wall 1 2 5 cm Min 2 5 cm M...

Страница 10: ...acturer Vent Termination Through The Wall PVC CPVC VENT SYSTEM PolyPro InnoFlue Two 2 90 degree PVC elbows are supplied with the water heater and shall be installed at the end of the vent and air intake piping to serve as the termination for through the wall installation when the vent system is built with PVC pipes If CPVC is used to build the vent system use 90 degree CPVC elbows that are approve...

Страница 11: ... A plastic tube can be attached to this outlet to drain any condensate that has accumulated away from the water heater Make sure that the condensate removal tube flows to a suitable free flowing drain Water Piping Refer to Figure 7 for a typical installation Use of this lay out should provide a trouble free installation for the life of the water heater Before making the plumbing connections locate...

Страница 12: ...ruction can result in premature failure of the water heater that is not covered by the warranty Check that all of the water piping connections have been made To fill the water heater 1 Make sure that the water heater drain valve is closed by inserting a flat head screwdriver into the slot on the head of the drain valve and turning the knob clockwise 2 Open the cold water supply manual shut off val...

Страница 13: ...operly secured as there is a possibility that they have become loose during transport If any of the original wiring needs replacing use only 18AWG type or greater wire that is approved for 221o F 105o C Installation Instructions for Water Heaters Approved for Combination Space Heating and Potable Water Heating see Figure 10 A water heater cannot be used for space heating only When using a water he...

Страница 14: ...ower Unit M High Limit Switch Vacuum Switch N C Power Cord Hot Surface Igniter Flame Sensor Flammable Vapor Sensor Gas Control 5 3 4 1 6 2 5 3 4 1 6 2 Vacuum Switch N O Jaune Bleu Jaune Unité de Ventilati M Interrupteur Haute Limite Interrupteur de Pression Négative N F Interrup Nég Unité de Ventilation M Interrupteur Haute Limite Interrupteur de Pression Négative N F Interrupteu Négati Figure 9 H...

Страница 15: ... under water Immediately call an EnerCare qualified installer or service agency to replace a flooded water heater Do not attempt to repair the unit It must be replaced 1 Set the thermostat to the lowest setting by first pressing the COOLER and HOTTER buttons at the same time and holding for one 1 second Then press the COOLER button until only the VAC indicator light is lit 2 Toggle the ON OFF swit...

Страница 16: ...70 21 Vacances 110 43 115 46 120 49 125 52 130 54 135 57 140 60 145 63 150 66 160 71 TEMPS NÉCESSAIRE POUR CAUSER UNE BRÛLURE S O 5 minutes 30 secondes 5 secondes 1 5 seconde moins d une seconde AFFICHAGE Figure 11 To decrease the temperature press and release the COOLER button once The temperature indicators will now display the new temperature setting Press and release the COOLER button until yo...

Страница 17: ...d the FV sensor is designed to automatically reset itself The Intelli Vent gas control however will have gone into lock out mode and will need to be manually reset An EnerCare qualified service technician must be called to determine if flammable vapours entered the combustion chamber and ignited In most instances there will not have been ignition of flammable vapours inside the combustion chamber ...

Страница 18: ...are issue but a consumer issue in the water supply and the consumer is responsible for any appa ratus needed to remove the rotten egg smell DANGER WARNING CAUTION AVERTISSEMENT ATTENTION Hydrogen gas can be produced in a hot water sys tem that has not been used for a long period of time generally two 2 weeks or more HYDROGEN GAS IS EXTREMELY FLAMMABLE It is highly recommended to open the hot water...

Страница 19: ... 2 Flammable Vapour Sensor 3 Protective Cover 4 Hot Surface Igniter 5 Burner Assembly 6 Inner Door 7 Jacket Door 8 Drain Valve 9 Overflow Tube 10 Dip tube 11 Temperature Pressure Relief Valve 12 Magnesium Anode 13 Flue Baffle 14 Inlet Rubber Adapter 15 Vacuum switch Inlet 16 Vacuum switch Outlet 17 High Limit Switch 18 Outlet Rubber Adapter 19 Blower Assembly 20 Outlet Nipple ...

Страница 20: ... the water heater Check and repair 7 The gas valve driver circuit 1 Turn off the power to the water heater for 10 seconds and then back on 2 If the above step did not clear the error replace the gas control valve 8 The internal microcomputer 1 Turn off the power to the water heater for 10 seconds and then back on 2 If the above step did not clear the error replace the gas control valve 9 The inter...

Страница 21: ...ol valve Replace with new gas control valve High operating costs Gas control valve set too high Turn temperature dial to desired temperature Sediment or lime in tank Drain Check to see if water treatment is necessary Water heater is undersized Install size of water heater that meets demand Wrong piping connections Correct piping dip tube must be in cold inlet Leaking faucets Repair faucets Gas lea...

Страница 22: ...roblem should go away If it persists check all plumbing connections for leaks Heavy draws of hot water with very cold refill water Let water heater warm up Problem should go away If it persists check all plumbing connections for leaks Water heater is undersized Install size of water heater that meets demand Combustion odours Insufficient secondary air Check that the air intake terminal is not bloc...

Страница 23: ..._________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________...

Страница 24: ...www directenergy com ...

Отзывы: