The gas control valve pictured in this manual is equipped 

with a single-use type automatic high temperature cut-off. 

Should the temperature of the water exceed 195

o

F (91

o

C), 

the high temperature cut-off will automatically shut off the 

gas supply to the water heater. If this situation occurs, the 

gas control valve must be replaced immediately replaced by 

EnerCare.

DANGER

WARNING

CAUTION

AVERTISSEMENT

ATTENTION

Should overheating occur or the gas supply fail to shut 

off, close the gas supply manual shut-off valve. Failure 

to follow this instruction can result in property damage, 

personal injury, or death.

Out of Fuel

If your water heater should run out of gas call EnerCare 
Home Services at 1-866-554-5591 and let them know your 
situation.

Housekeeping

Keep the area around the water heater clean and free of dust, 

lint, and dirt. It is the responsibility of the homeowner to do 

so in order to prevent any malfunc tion that is not EnerCare’s 

responsibility. 

DANGER

WARNING

CAUTION

AVERTISSEMENT

ATTENTION

DO NOT

 

store or use gasoline or other flammable 

vapours and liquids around the water heater.

DO NOT

 put or store any objects on the top of the water 

heater.  Failure to follow these instructions can result in 

property damage, personal injury, or death. 

Flammable Vapour Sensor

This water heater is equipped with a flammable vapour sen-
sor (FV) that will shut it down in the event of a flammable 
vapour incident. It is a safety feature that may prevent prop-
erty damage, personal injury, or death.

The FV sensor is located on the front left bottom of the exte-
rior casing of the water heater. The FV sensor is protected 
from shock and contaminants by a robust plastic cover. The 
function of the FV sensor is to detect the presence of flam-
mable vapours before they enter the combustion chamber 
and ignite. If the FV sensor detects the presence of flam-
mable vapours while the water heater is operating, the gas 
control will switch to lock-out mode and the water heater 
will shut down. If the water heater is not operating when the 
flammable vapours are detected, the control will switch to 
lock-out mode and prevent the water heater from lighting. 

After a flammable vapour incident has occurred and the flam-
mable vapours have dissipated, the FV sensor is designed 
to automatically reset itself. The Intelli-Vent

®

 gas control 

however, will have gone into lock-out mode and will need to 
be manually reset. An EnerCare qualified service technician 
must be called to determine if flammable vapours entered 
the combustion chamber and ignited. In most instances, 
there will not have been ignition of flammable vapours inside 
the combustion chamber because the FV sensor will have 
detected these vapours and shut down the water heater. In 
this case, the Intelli-Vent

®

 gas control can be reset and the 

water heater may resume normal operation. On the other 
hand, if the flammable vapours ignited inside the combus-
tion chamber, the water heater may need to be replaced. The 
EnerCare technician will be able to determine whether or not 
the water heater needs to be replaced based on the amount 
of flammable vapours that entered the combustion chamber 
and the damage to the water heater from the resulting fire.

Condensation

As moisture from the products of combustion comes into 
contact with the cold surface of the inner tank, it may con-
dense. This situation will usually occur:

1)  When the water heater is filled with cold water for the first 

time.

2)  If the water heater has been undersized.

3) When large amounts of hot water are drawn from the 

water heater in a short period of time and the refill water 
is very cold.

Due to the high-efficiency rating of this gas-fired water 
heater, it may produce more condensation than older mod-
els. Condensation forming on the flue tube will drop on 
the burner making a “sizzling” sound. This condition is not 
uncommon and must never be misinterpreted as a leaking 
tank. It will disappear once the water becomes heated.

Burner Ignitor Assembly

Every three (3) months, check the burner and flame ignitor 

assembly. Remove the outer access door and look through 

the sight glass to examine the flames. A soft blue flame indi-

cates proper gas combustion. A yellow tipped flame indicates 

poor combustion. If so, with a vacuum cleaner, remove any 

dust, lint, and dirt accumulation on or around the combus-

tion chamber. If the poor combustion persists and there is 

no lint around the water heater call EnerCare Home Services 

at 1-866-554-5591. This service call may be at the expenses 

of the consumer if lint is blocking the flame arrestor plate.

Water Heater Tank

You may choose to drain the tank at your convenience in very 

hard water conditions.

GENERAL MAINTENANCE

Содержание InnoFlue Centrotherm

Страница 1: ...or any other appliance WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your building From a neighbour s phone immediately call your gas supplier and EnerCare Home Services Follow their instructions If you cannot reach immediately the above suppliers call the fire department at 911 Installation and service must be performed on...

Страница 2: ...t nettoyant liquide Éviter les endroits humides et les températures sous le point de congélation Si le détecteur décèle la présence de vapeurs inflammables le contôle au gaz se vérouillera et le chauffe eau cessera de fonctionner Ne tentez pas de le remettre en marche Faite inspecter le chauffe eau immédiatement par un technicien de service qualifié ou le fournisseur de gaz ATTENTION Safety Inform...

Страница 3: ...ert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING Serious injury or death can occur if you do not fol low the instructions immediately Serious injury or death can occur if you do not fol low the instructions WARNING AVERTISSEMENT DANGER WARNING AVERTISSEMENT DANGE...

Страница 4: ...or this water heater are Two 2 inches 5 1 cm from the sides and rear four 4 inches 10 2 cm from the front and eighteen 18 inches 45 7 cm from the top see Figure 1 18 min 2 min 2 min 2 min 4 min Figure 1 Venting DANGER WARNING CAUTION AVERTISSEMENT ATTENTION When installing the venting system make sure to follow all local codes or in the absence of local codes the latest edition of CAN CSA B149 1 N...

Страница 5: ...1 NFPA 54 in the United States see Figure 3 This water heater must be vented directly to the outdoors either horizontally through the wall or vertically through the roof The venting must not be attached to an existing chimney or in com mon with any other appliance and must not be insulated If possible locate the water heater so that the venting length and number of elbows are kept to the minimum n...

Страница 6: ...6 INSTALLATION INSTRUCTIONS 2 18 min 3 min 8 max 18 min 8 min IN ANY DIRECTION 8 min See Figure 6A 90 INTAKE TERMINAL 18 min 90 INTAKE TERMINAL 18 min VENT TERMINAL Figure 2 ...

Страница 7: ...d within ten 10 feet 3 05 m The Vent Termination must have a Canadian Installations U S Installations A Clearance above grade veranda porch deck or balcony 12 inches 30 cm 12 inches 30 cm B Clearance to window or door that may be opened 12 inches 30 cm 9 inches 23 cm or 12 inches 30 cm C Clearance to outside corner D Clearance to inside corner 3 feet 91 cm E Clearance to service regulator vent out...

Страница 8: ...nce around the piping for air circulation FOR PVC AND CPVC PIPING PolyPro InnoFlue Make sure that all horizontal runs have a minimum rise of 1 4 inch per foot 21 mm m of run see Figure 7 Horizontal runs of vent pipe must be supported every three 3 feet 91 cm FOR POLYPROPYLENE PIPE FROM CENTROTHERM Innoflue single wall vent system PolyPro InnoFlue Make sure that all horizontal runs have a minimum r...

Страница 9: ... horizontal runs have a minimum rise of 5 8 inch per foot 56 mm m of run Follow instruction of the vent pipe manufacturer for proper vent support Clamp or Strap field supplied 1 2 5 cm Min 2 5 cm Max Exhaust Optional Elbow see local codes voir codes locaux Coude optionnel Exhaust Distance above average snowfall or grade reference CSA B149 1 Air intake Air intake Exterior wall 1 2 5 cm Min 2 5 cm M...

Страница 10: ...acturer Vent Termination Through The Wall PVC CPVC VENT SYSTEM PolyPro InnoFlue Two 2 90 degree PVC elbows are supplied with the water heater and shall be installed at the end of the vent and air intake piping to serve as the termination for through the wall installation when the vent system is built with PVC pipes If CPVC is used to build the vent system use 90 degree CPVC elbows that are approve...

Страница 11: ... A plastic tube can be attached to this outlet to drain any condensate that has accumulated away from the water heater Make sure that the condensate removal tube flows to a suitable free flowing drain Water Piping Refer to Figure 7 for a typical installation Use of this lay out should provide a trouble free installation for the life of the water heater Before making the plumbing connections locate...

Страница 12: ...ruction can result in premature failure of the water heater that is not covered by the warranty Check that all of the water piping connections have been made To fill the water heater 1 Make sure that the water heater drain valve is closed by inserting a flat head screwdriver into the slot on the head of the drain valve and turning the knob clockwise 2 Open the cold water supply manual shut off val...

Страница 13: ...operly secured as there is a possibility that they have become loose during transport If any of the original wiring needs replacing use only 18AWG type or greater wire that is approved for 221o F 105o C Installation Instructions for Water Heaters Approved for Combination Space Heating and Potable Water Heating see Figure 10 A water heater cannot be used for space heating only When using a water he...

Страница 14: ...ower Unit M High Limit Switch Vacuum Switch N C Power Cord Hot Surface Igniter Flame Sensor Flammable Vapor Sensor Gas Control 5 3 4 1 6 2 5 3 4 1 6 2 Vacuum Switch N O Jaune Bleu Jaune Unité de Ventilati M Interrupteur Haute Limite Interrupteur de Pression Négative N F Interrup Nég Unité de Ventilation M Interrupteur Haute Limite Interrupteur de Pression Négative N F Interrupteu Négati Figure 9 H...

Страница 15: ... under water Immediately call an EnerCare qualified installer or service agency to replace a flooded water heater Do not attempt to repair the unit It must be replaced 1 Set the thermostat to the lowest setting by first pressing the COOLER and HOTTER buttons at the same time and holding for one 1 second Then press the COOLER button until only the VAC indicator light is lit 2 Toggle the ON OFF swit...

Страница 16: ...70 21 Vacances 110 43 115 46 120 49 125 52 130 54 135 57 140 60 145 63 150 66 160 71 TEMPS NÉCESSAIRE POUR CAUSER UNE BRÛLURE S O 5 minutes 30 secondes 5 secondes 1 5 seconde moins d une seconde AFFICHAGE Figure 11 To decrease the temperature press and release the COOLER button once The temperature indicators will now display the new temperature setting Press and release the COOLER button until yo...

Страница 17: ...d the FV sensor is designed to automatically reset itself The Intelli Vent gas control however will have gone into lock out mode and will need to be manually reset An EnerCare qualified service technician must be called to determine if flammable vapours entered the combustion chamber and ignited In most instances there will not have been ignition of flammable vapours inside the combustion chamber ...

Страница 18: ...are issue but a consumer issue in the water supply and the consumer is responsible for any appa ratus needed to remove the rotten egg smell DANGER WARNING CAUTION AVERTISSEMENT ATTENTION Hydrogen gas can be produced in a hot water sys tem that has not been used for a long period of time generally two 2 weeks or more HYDROGEN GAS IS EXTREMELY FLAMMABLE It is highly recommended to open the hot water...

Страница 19: ... 2 Flammable Vapour Sensor 3 Protective Cover 4 Hot Surface Igniter 5 Burner Assembly 6 Inner Door 7 Jacket Door 8 Drain Valve 9 Overflow Tube 10 Dip tube 11 Temperature Pressure Relief Valve 12 Magnesium Anode 13 Flue Baffle 14 Inlet Rubber Adapter 15 Vacuum switch Inlet 16 Vacuum switch Outlet 17 High Limit Switch 18 Outlet Rubber Adapter 19 Blower Assembly 20 Outlet Nipple ...

Страница 20: ... the water heater Check and repair 7 The gas valve driver circuit 1 Turn off the power to the water heater for 10 seconds and then back on 2 If the above step did not clear the error replace the gas control valve 8 The internal microcomputer 1 Turn off the power to the water heater for 10 seconds and then back on 2 If the above step did not clear the error replace the gas control valve 9 The inter...

Страница 21: ...ol valve Replace with new gas control valve High operating costs Gas control valve set too high Turn temperature dial to desired temperature Sediment or lime in tank Drain Check to see if water treatment is necessary Water heater is undersized Install size of water heater that meets demand Wrong piping connections Correct piping dip tube must be in cold inlet Leaking faucets Repair faucets Gas lea...

Страница 22: ...roblem should go away If it persists check all plumbing connections for leaks Heavy draws of hot water with very cold refill water Let water heater warm up Problem should go away If it persists check all plumbing connections for leaks Water heater is undersized Install size of water heater that meets demand Combustion odours Insufficient secondary air Check that the air intake terminal is not bloc...

Страница 23: ..._________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________...

Страница 24: ...www directenergy com ...

Отзывы: