OMNI-Test Laboratories, Inc.
Manufacturer:
Model:
Run:
Category:
BR – Dry burn rate, kg/hr
V
s
– Average gas velocity in the dilution tunnel, ft/sec
Q
sd
– Average gas flow rate in dilution tunnel, dscf/hr
V
m(std)
– Volume of gas sampled, corrected to dry standard conditions, dscf
m
n
– Total particulate matter collected, mg
C
s
- Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dscf
E
T
– Total particulate emissions, g
PR - Proportional rate variation
PM
R
– Particulate emissions for test run, g/hr
PM
F
– Particulate emission factor for test run, g/dry kg of fuel burned
Equations and Sample Calculations – ASTM E3053 & E2515
GHP Group
GHP Large
2
are provided for each equation. The raw data and printout results from a sample run are also provided for
Equations used to calculate the parameters listed below are described in this appendix. Sample calculations
comparison to the sample calculations.
Control No. P-SSAR-0003
Medium Burn Run 2
Содержание GWS-2200
Страница 26: ...26 of 142 ...
Страница 35: ...35 of 142 ...
Страница 36: ...36 of 142 ...
Страница 55: ...55 of 142 ...
Страница 56: ...56 of 142 ...
Страница 64: ...64 of 142 ...
Страница 65: ...65 of 142 ...
Страница 73: ...73 of 142 ...
Страница 74: ...74 of 142 ...
Страница 78: ...78 of 142 ...
Страница 79: ...79 of 142 ...
Страница 80: ...80 of 142 ...
Страница 81: ...81 of 142 ...
Страница 82: ...82 of 142 ...
Страница 83: ...83 of 142 ...
Страница 84: ...84 of 142 ...
Страница 85: ...85 of 142 ...
Страница 86: ...86 of 142 ...
Страница 88: ...88 of 142 ...
Страница 89: ...89 of 142 ...
Страница 90: ...90 of 142 ...
Страница 91: ...91 of 142 ...
Страница 94: ...94 of 142 ...
Страница 97: ...97 of 142 ...
Страница 98: ...98 of 142 ...
Страница 99: ...99 of 142 ...
Страница 138: ...227 of 229 ...
Страница 139: ...228 of 229 ...
Страница 140: ...229 of 229 ...
Страница 141: ...GHP Group Inc Model Large Wood Stove Report Number 0418WS018E OMNI Test Laboratories Inc Appendix C Firebox Volume ...