OMNI-Test Laboratories, Inc.
Run:
1
GHP Group
PM Control Modules:
371, 372
Large
Dilution Tunnel MW(dry):
29.00 lb/lb-mole
Avg. Tunnel Velocity:
20.14
ft/sec.
2409
123
min
Dilution Tunnel MW(wet):
28.78 lb/lb-mole
Initial Tunnel Flow:
218.2
scfm
Technician Signature:________________________________
0418WS018E
Recording Interval:
1
min
Dilution Tunnel H2O:
2.00 percent
Average Tunnel Flow:
200.0
scfm
05-May-20
Dilution Tunnel Static:
-0.248
"H2O
Post-Test Leak Check (1):
0.000
cfm @
14
in. Hg
Beginning Clock Time:
10:28
Background Sample Volume:
cubic feet
Tunnel Area:
0.19635
ft2
Post-Test Leak Check (2):
0.000
cfm @
14
in. Hg
Pitot Tube Cp:
0.99
Average Test Piece Fuel Moisture:
20.43
Dry Basis %
Meter Box Y Factor:
0.988
(1)
0.985
(2)
(Amb)
Barometric Pressure:
Begin
Middle
End
Average
Pt.1
Pt.2
Pt.3
Pt.4
Pt.5
Pt.6
Pt.7
Pt.8
Center
29.43
29.41
29.42 "Hg
Initial dP
0.074
0.096
0.096
0.088
0.070
0.080
0.096
0.088
0.098
"H2O
OMNI Equipment Numbers:
Temp:
87
87
87
87
87
87
87
87
87
°F
V
strav
20.07
ft/sec
V
scent
21.30
ft/sec
F
p
0.942
Particulate Sampling Data
Elapsed
Time (min)
Gas Meter
1 (ft
3
)
Gas
Meter 2
(ft
3
)
Sample
Rate 1
(cfm)
Sample
Rate 2
(cfm)
Orifice
dH 1
("H
2
O)
Meter 1
Temp
(°F)
Meter 1
Vacuum
("Hg)
Orifice
dH 2
("H
2
O)
Meter 2
Temp (°F)
Meter 2
Vacuum
("Hg)
Dilution
Tunnel (°F)
Dilution
Tunnel
Center dP
Pro. Rate
1
Pro. Rate
2
Scale
Reading
Weight
Change
Firebox Top
Firebox
Bottom
Firebox
Back
Firebox Left
Firebox
Right
Avg. Stove
Surface
Stack
Filter 1
Dryer Exit
1
Filter 2
Dryer Exit
2
Ambient
Draft
("H
2
O)
CO
2
(%)
CO
(%)
Wood Heater Test Data - ASTM E3053 / ASTM E2515
Test Date:
Stack Gas Data
Fuel Weight (lb)
Temperature Data (°F)
Velocity Traverse Data
Manufacturer:
Model:
Tracking No.:
Total Sampling Time:
Project No.:
108
17.695
18.747
0.17
0.18
2.28
85
-0.76
1.83
83
-3.6
134
0.090
100
100
3.3
-0.1
634
504
397
473
580
518
466
84
60
83
61
78
-0.094
10
0
109
17.862
18.925
0.17
0.18
2.29
85
-0.7
1.84
83
-3.3
133
0.090
99
100
3.2
-0.1
625
507
396
475
578
516
465
83
60
83
61
78
-0.094
9.84
0
110
18.031
19.104
0.17
0.18
2.29
86
-0.47
1.85
84
-3.5
132
0.090
100
101
3.1
-0.1
621
509
389
477
578
515
462
83
60
83
62
77
-0.094
9.7
0
111
18.199
19.283
0.17
0.18
2.32
86
-0.37
1.85
84
-3.2
131
0.090
100
100
3.0
-0.1
612
511
382
479
577
512
457
83
60
83
62
78
-0.093
9.46
0
112
18.367
19.462
0.17
0.18
2.30
86
-0.6
1.86
84
-3.5
130
0.090
100
100
2.9
-0.1
605
512
377
480
575
510
453
83
60
83
62
78
-0.091
9.16
0.02
113
18.535
19.641
0.17
0.18
2.32
86
-0.69
1.87
84
-3.4
129
0.090
100
100
2.8
-0.1
596
514
373
482
574
508
446
83
61
83
62
78
-0.090
8.48
0.05
114
18.704
19.821
0.17
0.18
2.33
86
-0.68
1.87
84
-3.2
128
0.090
100
101
2.7
-0.1
591
516
367
483
573
506
439
83
61
82
62
77
-0.089
8.01
0.07
115
18.873
20.002
0.17
0.18
2.33
86
-0.3
1.90
84
-3.3
128
0.090
100
101
2.6
-0.1
579
517
363
484
571
503
435
83
61
82
63
78
-0.090
7.99
0.05
116
19.041
20.179
0.17
0.18
2.24
86
-0.58
1.75
84
-3.2
127
0.090
99
99
2.6
0
573
519
358
484
570
501
431
82
61
82
63
78
-0.089
8
0.06
117
19.207
20.352
0.17
0.17
2.25
86
-0.49
1.75
84
-2.9
127
0.090
98
97
2.5
-0.1
566
520
357
485
569
499
426
82
61
82
63
78
-0.088
7.85
0.06
118
19.373
20.527
0.17
0.18
2.25
86
-0.27
1.75
84
-2.9
126
0.090
98
98
2.4
-0.1
559
522
354
484
567
497
422
82
61
82
63
78
-0.088
7.85
0.07
119
19.538
20.701
0.16
0.17
2.25
86
-0.71
1.77
84
-3.1
126
0.090
98
97
2.3
-0.1
554
523
354
483
566
496
419
82
61
82
63
78
-0.088
7.89
0.07
120
19.704
20.876
0.17
0.18
2.25
86
-0.36
1.77
84
-3
125
0.090
98
98
2.3
0
552
524
355
483
564
496
417
82
61
82
63
78
-0.087
7.92
0.08
121
19.871
21.051
0.17
0.17
2.26
86
-0.51
1.76
84
-3
125
0.090
99
98
2.2
-0.1
549
525
356
482
562
495
414
82
61
82
63
78
-0.087
7.95
0.09
122
20.038
21.226
0.17
0.18
2.27
86
-0.61
1.78
84
-2.8
124
0.090
99
98
2.1
-0.1
539
526
351
482
561
492
409
82
61
81
64
79
-0.087
7.4
0.09
123
20.204
21.402
0.17
0.18
2.26
86
-0.18
1.78
84
-2.9
124
0.090
98
98
2.0
-0.1
534
527
351
480
558
490
406
82
61
81
64
78
-0.087
7.37
0.1
Avg/Tot
20.204
21.402
0.16
0.17
2.24
80
1.77
78
143
0.089
100
100
424.2
57
85
58
78
-0.095
Control No. P-SSAR-0003
Page 6 of 9
High Burn Run 1
31 of 142
re:______________
_
_
_
_
_
_______
__
___________
Содержание GWS-2200
Страница 26: ...26 of 142 ...
Страница 35: ...35 of 142 ...
Страница 36: ...36 of 142 ...
Страница 55: ...55 of 142 ...
Страница 56: ...56 of 142 ...
Страница 64: ...64 of 142 ...
Страница 65: ...65 of 142 ...
Страница 73: ...73 of 142 ...
Страница 74: ...74 of 142 ...
Страница 78: ...78 of 142 ...
Страница 79: ...79 of 142 ...
Страница 80: ...80 of 142 ...
Страница 81: ...81 of 142 ...
Страница 82: ...82 of 142 ...
Страница 83: ...83 of 142 ...
Страница 84: ...84 of 142 ...
Страница 85: ...85 of 142 ...
Страница 86: ...86 of 142 ...
Страница 88: ...88 of 142 ...
Страница 89: ...89 of 142 ...
Страница 90: ...90 of 142 ...
Страница 91: ...91 of 142 ...
Страница 94: ...94 of 142 ...
Страница 97: ...97 of 142 ...
Страница 98: ...98 of 142 ...
Страница 99: ...99 of 142 ...
Страница 138: ...227 of 229 ...
Страница 139: ...228 of 229 ...
Страница 140: ...229 of 229 ...
Страница 141: ...GHP Group Inc Model Large Wood Stove Report Number 0418WS018E OMNI Test Laboratories Inc Appendix C Firebox Volume ...