OMNI-Test Laboratories, Inc.
V
m(std)
– Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf
ASTM E2515 equation (6)
Where:
K
1
=
17.64
°
R/in. Hg
V
m
=
Volume of gas sample measured at the dry gas meter, dcf
Y
=
Dry gas meter calibration factor, dimensionless
P
bar
=
Barometric pressure at the testing site, in. Hg
ѐ
H
=
Average pressure differential across the orifice meter, in. H
2
O
T
m
=
Absolute average dry gas meter temperature,
°
R
Sample Calculation:
Using equation for Train 1:
2.27
V
m(std)
=
17.64
x 79.621 x
0.988
x
13.6
(
87.0
+
460
)
V
m(std)
=
74.992
dscf
Using equation for Train 2:
1.82
V
m(std)
=
17.64
x 84.432 x
0.985
x
13.6
(
85.5
+
460
)
V
m(std)
=
79.417
dscf
Using equation for ambient train:
0.00
V
m(std)
=
17.64
x
0.00
x
0
x
13.6
(
79.4 +
460
)
V
m(std)
=
0
dscf
+
)
(
29.4
)
+
29.4 +
)
(
(
29.4
Control No. P-SSAR-0003
Medium Burn Run 2
Содержание GWS-2200
Страница 26: ...26 of 142 ...
Страница 35: ...35 of 142 ...
Страница 36: ...36 of 142 ...
Страница 55: ...55 of 142 ...
Страница 56: ...56 of 142 ...
Страница 64: ...64 of 142 ...
Страница 65: ...65 of 142 ...
Страница 73: ...73 of 142 ...
Страница 74: ...74 of 142 ...
Страница 78: ...78 of 142 ...
Страница 79: ...79 of 142 ...
Страница 80: ...80 of 142 ...
Страница 81: ...81 of 142 ...
Страница 82: ...82 of 142 ...
Страница 83: ...83 of 142 ...
Страница 84: ...84 of 142 ...
Страница 85: ...85 of 142 ...
Страница 86: ...86 of 142 ...
Страница 88: ...88 of 142 ...
Страница 89: ...89 of 142 ...
Страница 90: ...90 of 142 ...
Страница 91: ...91 of 142 ...
Страница 94: ...94 of 142 ...
Страница 97: ...97 of 142 ...
Страница 98: ...98 of 142 ...
Страница 99: ...99 of 142 ...
Страница 138: ...227 of 229 ...
Страница 139: ...228 of 229 ...
Страница 140: ...229 of 229 ...
Страница 141: ...GHP Group Inc Model Large Wood Stove Report Number 0418WS018E OMNI Test Laboratories Inc Appendix C Firebox Volume ...