OMNI-Test Laboratories, Inc.
Manufacturer: GHP Group
Model: GHP Large
Project No.: 0418WS018E
Tracking No.: 2409
Run: 2
Test Date:
Burn Rate
1.18 kg/hr dry
Average Tunnel Temperature
97 degrees Fahrenheit
Average Gas Velocity in Dilution Tunnel - vs
20.62 feet/second
Average Gas Flow Rate in Dilution Tunnel - Qsd
13295.6 dscf/hour
Average Delta p
0.099 inches H20
Total Time of Test
475 minutes
Total Sample Volume - Vm
0.000 cubic feet
79.621 cubic feet
84.432 cubic feet
9.979 cubic feet
Average Gas Meter Temperature
79 degrees Fahrenheit
87 degrees Fahrenheit
85 degrees Fahrenheit
88 degrees Fahrenheit
Total Sample Volume (Standard Conditions) - Vmstd
0.000 dscf
74.992 dscf
79.417 dscf
9.383 dscf
Total Particulates - m
n
0 mg
5.1 mg
4.6 mg
3.7 mg
Particulate Concentration (dry-standard) - C
r
/C
s
0.000000 grams/dscf
0.00007 grams/dscf
0.00006 grams/dscf
0.00039 grams/dscf
Total Particulate Emissions - E
T
0.00 grams
7.16 grams
6.10 grams
5.24 grams
Particulate Emission Rate
0.00 grams/hour
0.90 grams/hour
0.77 grams/hour
5.24 grams/hour
Emissions Factor
0.77 g/kg
0.65 g/kg
1.11 g/kg
Difference from Average Total Particulate Emissions
0.53 grams
0.53 grams
Complete Test Run
Total Particulate Emissions - E
T
6.63 grams
Particulate Emission Rate
0.84 grams/hour
Emissions Factor
0.71 grams/kg
First Hour Emissions
Total Particulate Emissions - E
T
5.24 grams
Particulate Emission Rate
5.24 grams/hour
Emissions Factor
1.11 grams/kg
7.5% of Average Total Particulate Emissions
0.50 grams
Technician Signature:_____________________________________________________
Wood Heater Test Results - ASTM E3053 / ASTM E2515
05/05/20
SAMPLE TRAIN 1
SAMPLE TRAIN 2
AMBIENT
QUALITY CHECKS
FINAL AVERAGE RESULTS
FIRST HOUR FILTER (TRAIN 1)
Dual Train Comparison Results Are Acceptable
Filter Temps < 90
°
F
OK
OK
OK
OK
Stove Surface
∆
T
NOT ACCEPTABLE
OK
Filter Face Velocity (47 mm)
Dryer Exit Temp < 80F
Leakage Rate
Ambient Temp (55-90
°
F)
Negative Probe Weight Eval.
OK
Pro-Rate Variation
OK
Control No. P-SSAR-0003
Medium Burn Run 2
52 of 142
e:__________________________________
Содержание GWS-2200
Страница 26: ...26 of 142 ...
Страница 35: ...35 of 142 ...
Страница 36: ...36 of 142 ...
Страница 55: ...55 of 142 ...
Страница 56: ...56 of 142 ...
Страница 64: ...64 of 142 ...
Страница 65: ...65 of 142 ...
Страница 73: ...73 of 142 ...
Страница 74: ...74 of 142 ...
Страница 78: ...78 of 142 ...
Страница 79: ...79 of 142 ...
Страница 80: ...80 of 142 ...
Страница 81: ...81 of 142 ...
Страница 82: ...82 of 142 ...
Страница 83: ...83 of 142 ...
Страница 84: ...84 of 142 ...
Страница 85: ...85 of 142 ...
Страница 86: ...86 of 142 ...
Страница 88: ...88 of 142 ...
Страница 89: ...89 of 142 ...
Страница 90: ...90 of 142 ...
Страница 91: ...91 of 142 ...
Страница 94: ...94 of 142 ...
Страница 97: ...97 of 142 ...
Страница 98: ...98 of 142 ...
Страница 99: ...99 of 142 ...
Страница 138: ...227 of 229 ...
Страница 139: ...228 of 229 ...
Страница 140: ...229 of 229 ...
Страница 141: ...GHP Group Inc Model Large Wood Stove Report Number 0418WS018E OMNI Test Laboratories Inc Appendix C Firebox Volume ...