background image

Bedienungsanleitung                          
 

As of 04/20/2010 

Seite 12/16 

4

 

Hardware modules 

4.1

 

General 

The 

Expansion Box

 is modularly expandable. To be able to use additional sensors, powerbars, dimmable 

lamps etc., the installation of up to 5 additional modules is possible. 

Hint 

In case of any change (add, remove or exchange) of module cards the 

Expansion Box

 

needs to be assigned again to the ProfiLux, so that the ProfiLux detects and stores the 
changes. Thereby the assignment of the resources in the ProfiLux may change. 
Therefore all assignments should be checked before reactivation. 

 
To be able to use the modules, possibly a firmware update of the 

Expansion Box

 or aquarium computer is 

necessary. Have a look here also at the instructions which are delivered together with the module. 

If you do not like to do the installation by yourself, we can do this for you for a low charge (possibly 
together with a firmware-update). 

Hint 

In the last slot Modul 4 only analog measurement cards are supported at the 
moment. Intelligent cards – like 

PLM-2L4S

PLM-4L

PLM-Humidity-Temp

PLM-ADIN

 

or similar – can’t be operated there. 

 

The firmware 1.02 supports the following cards 

Analog measurement cards 

Double measurement cards 

Intelligent cards 

PLM-pH

 

PLM-pH-Temp

 

PLM-2L4

 

PLM-Temp

 

PLM-pH-Redox

 

PLM-4L

 

PLM-Redox

 

PLM-CondS-Redox

 

PLM-Humidity-Temp

 

PLM-CondS

 

PLM-CondF-Redox

 

PLM-ADIN

 

PLM-CondF

 

PLM-CondS-pH

 

 

PLM-Oxygen

 

PLM-CondF-pH

 

 

 
The installation of a module requires greatest care! You have to pay attention that 

 

First the aquarium computer is currentless (remove plug of power supply) 

 

The electronics is not damaged through electrostatic charging (ground resp. discharge yourself; 
earthed work environment) 

 

You treat the housing with special care. 

Содержание ProfiLux Expansion Box

Страница 1: ...User manual for Expansion Box Valid for Firmware version 1 02 and later As of 04 20 2010...

Страница 2: ...SION BOX 6 3 ASSIGN THE EXPANSION BOX TO THE PROFILUX 7 3 1 REQUIREMENTS 7 3 2 ASSIGN THE EXPANSION BOX 7 3 3 THE RESOURCES SENSORS AND INTERFACES OF THE EXPANSION BOX 7 3 4 THE SENSORS OF THE EXPANSI...

Страница 3: ...sensor Connection option for pH sensor Connection option for a conductivity sensor selectable for salt or fresh water Connection option for a Redox sensor Connection option for 2 level sensors 5 expa...

Страница 4: ...o not use force to plug in Important A false connection e g plugging in a light bar plug into a powerbar socket can lead to a destruction of the ProfiLux A possible repair is no warranty case and ther...

Страница 5: ...selection switch 6 in order that the conductivity is measured correctly The control cables of dimmable lamps light bars hanging lamps moonlight etc or controllable current pumps are plugged into the...

Страница 6: ...ox has two light emitting diodes 17 18 on the rear side for the status display not available on some devices The state LED 17 is the lower one the communication LED 18 is above Display Meaning State L...

Страница 7: ...ning the resources are ordered in the ProfiLux in the following manner The numbering starts in every case with the internal resources of the ProfiLux followed by the resources of the module cards inst...

Страница 8: ...2 Conductivity S 2 and Redox 2 are the internal sensor inputs of the first found by ProfiLux Expansion Box Airtemperature 1 and Humidity 1 originate from the PLM Humidity Temp in this Expansion Box L...

Страница 9: ...ards in the slots of the Expansion Box Thereafter the interfaces of the second Expansion Box follow and so on Example In case of a ProfiLux 3 with a PLM 4L card and an Expansion Box with a PLM 4L the...

Страница 10: ...ssigning the devices Only if all sensors and interfaces are checked and correctly assigned again the disabled devices can return to in operation again 3 6 The switching outputs of the Expansion Box Th...

Страница 11: ...here the PLM 2L4S at the Expansion Box Here only the switching outputs from S1 to S16 are available the others are free Attention During assigning devices it is also possible here that the numbering...

Страница 12: ...the module If you do not like to do the installation by yourself we can do this for you for a low charge possibly together with a firmware update Hint In the last slot Modul 4 only analog measurement...

Страница 13: ...nsert the module The new module can be inserted into any slot except slot Modul 4 slot nearest to the housing This slot only supports analog measurement cards at the moment When you insert it pay atte...

Страница 14: ...ection We assume no liability for direct damages indirect damages consequential damages and third party damages as far as it is legally permitted We do not take over guarantee that our product package...

Страница 15: ...voltage 12 VDC Power consumption 200 mA pH measurement BNC input for pH sensors accuracy 0 1 pH measurement range 3 0 pH to 10 5 pH Temperature measurement Mini DIN socket for delivered temperature s...

Страница 16: ...Bedienungsanleitung As of 04 20 2010 Seite 16 16...

Отзывы: