Hint 

Before updating the firmware there must be made sure that only one PAB device (this 
Expansion Box) is connected directly to the ProfiLux. Other PAB devices at the 
ProfiLux during the update are 

not

 allowed! 

 
During the firmware update the sensors are not read, measurement values are not available. Interface 
outputs (pumps, illuminations) aren’t accessed anymore. Therefore all accessed devices (like pumps, 
valves, switching plugs, dosing pumps …) should be disabled or disconnected. Sensors or illuminations are 
generally noncritical and can remain connected. 

7

 

Technical data 

Input voltage 

12 VDC 

Power consumption 

200 mA 

pH-measurement 

BNC input for pH-sensors, accuracy 0.1 pH, measurement range    
3.0 pH to 10.5 pH 

Temperature measurement 

Mini-DIN socket for delivered temperature sensor, accuracy 0.1 °C, 
measurement range 11.5 °C to 38 °C 

Conductivity measurement 

BNC input for conductivity sensor, in fresh water accuracy 1 µS, 
measurement range 0 µs to 2000 µS, in salt water accuracy 0.1 mS, 
0 mS to 100 mS 

Redox measurement 

BNC input for Redox sensor, accuracy 1 mV, measurement range         
-1000 mV to 1000 mV 

Level inputs 

Mini-DIN socket for 2 level inputs 

Control dimmable lamps 

2 modular jacks a‘ 2 dimming channels with analog output each 1-
10 V for light intensity control and shut off 

Dimensions 

H x B x T = 58 mm x 240 mm x 198 mm 

Module slots 

5 (4 for all module card types, one only for analog measurement 
cards) 

 

 

 

Содержание ProfiLux Expansion Box

Страница 1: ...User manual for Expansion Box Valid for Firmware version 1 02 and later As of 04 20 2010...

Страница 2: ...SION BOX 6 3 ASSIGN THE EXPANSION BOX TO THE PROFILUX 7 3 1 REQUIREMENTS 7 3 2 ASSIGN THE EXPANSION BOX 7 3 3 THE RESOURCES SENSORS AND INTERFACES OF THE EXPANSION BOX 7 3 4 THE SENSORS OF THE EXPANSI...

Страница 3: ...sensor Connection option for pH sensor Connection option for a conductivity sensor selectable for salt or fresh water Connection option for a Redox sensor Connection option for 2 level sensors 5 expa...

Страница 4: ...o not use force to plug in Important A false connection e g plugging in a light bar plug into a powerbar socket can lead to a destruction of the ProfiLux A possible repair is no warranty case and ther...

Страница 5: ...selection switch 6 in order that the conductivity is measured correctly The control cables of dimmable lamps light bars hanging lamps moonlight etc or controllable current pumps are plugged into the...

Страница 6: ...ox has two light emitting diodes 17 18 on the rear side for the status display not available on some devices The state LED 17 is the lower one the communication LED 18 is above Display Meaning State L...

Страница 7: ...ning the resources are ordered in the ProfiLux in the following manner The numbering starts in every case with the internal resources of the ProfiLux followed by the resources of the module cards inst...

Страница 8: ...2 Conductivity S 2 and Redox 2 are the internal sensor inputs of the first found by ProfiLux Expansion Box Airtemperature 1 and Humidity 1 originate from the PLM Humidity Temp in this Expansion Box L...

Страница 9: ...ards in the slots of the Expansion Box Thereafter the interfaces of the second Expansion Box follow and so on Example In case of a ProfiLux 3 with a PLM 4L card and an Expansion Box with a PLM 4L the...

Страница 10: ...ssigning the devices Only if all sensors and interfaces are checked and correctly assigned again the disabled devices can return to in operation again 3 6 The switching outputs of the Expansion Box Th...

Страница 11: ...here the PLM 2L4S at the Expansion Box Here only the switching outputs from S1 to S16 are available the others are free Attention During assigning devices it is also possible here that the numbering...

Страница 12: ...the module If you do not like to do the installation by yourself we can do this for you for a low charge possibly together with a firmware update Hint In the last slot Modul 4 only analog measurement...

Страница 13: ...nsert the module The new module can be inserted into any slot except slot Modul 4 slot nearest to the housing This slot only supports analog measurement cards at the moment When you insert it pay atte...

Страница 14: ...ection We assume no liability for direct damages indirect damages consequential damages and third party damages as far as it is legally permitted We do not take over guarantee that our product package...

Страница 15: ...voltage 12 VDC Power consumption 200 mA pH measurement BNC input for pH sensors accuracy 0 1 pH measurement range 3 0 pH to 10 5 pH Temperature measurement Mini DIN socket for delivered temperature s...

Страница 16: ...Bedienungsanleitung As of 04 20 2010 Seite 16 16...

Отзывы: