Assign the Expansion Box to the ProfiLux 

3.1

 

Requirements 

Before the 

Expansion Box

 can be assigned to the ProfiLux, all hardware modules have to build in. 

Furthermore it is important that the select switch for the conductance is in the right position for the used 
sensor type and the 

Expansion Box 

is powered up. 

3.2

 

Assign the Expansion Box 

If all PAB connections have been made and power supplied to all devices at the PAB, the Expansion Box 
can be assigned. Therefore select menu item

 Assign devices

 

in ProfiLux system menu

 

Config 

PAB

. The ProfiLux scans all devices connected at the PAB and afterwards the serial numbers of the found 

devices are displayed. Then select 

all

 the serials you want to assign to this ProfiLux and accept with the 

Return

-key. 

Further information can be found at 

Description PAB

After this the resources (sensors and interfaces) of the 

Expansion Box

 are available.   

3.3

 

The resources (sensors and interfaces) of the Expansion Box 

After assigning, the resources are ordered in the ProfiLux in the following manner: 

The numbering starts in every case with the internal resources of the ProfiLux, followed by the resources 
of the module cards installed in the slots of the ProfiLux. The numbering of the resources of the module 
cards depends on the order in the slots. 

Then the resources of the first found and assigned PAB device follows, afterwards those of the second PAB 
device, and so on.  

The resources in an expansion box are numbered just as those at the ProfiLux. First the internal resources 
of the 

Expansion Box

, then the resources of the module cards in the slots of the 

Expansion Box

. The 

numbering of the resources of the module cards depends on the order in the slots, too. 

3.4

 

The sensors of the Expansion Box 

When the 

Expansion Box

 has been assigned to the ProfiLux, then the additional sensors and interfaces are 

available immediately. 

The numbering starts with the internal sensors followed by the sensors on the module cards at the 
ProfiLux. Then the internal sensors of the first 

Expansion Box 

found by the ProfiLux and the sensors on the 

module cards in the slots of the 

Expansion Box

. After then the sensors of the second 

Expansion Box

, and so 

on. 

 

 

Содержание ProfiLux Expansion Box

Страница 1: ...User manual for Expansion Box Valid for Firmware version 1 02 and later As of 04 20 2010...

Страница 2: ...SION BOX 6 3 ASSIGN THE EXPANSION BOX TO THE PROFILUX 7 3 1 REQUIREMENTS 7 3 2 ASSIGN THE EXPANSION BOX 7 3 3 THE RESOURCES SENSORS AND INTERFACES OF THE EXPANSION BOX 7 3 4 THE SENSORS OF THE EXPANSI...

Страница 3: ...sensor Connection option for pH sensor Connection option for a conductivity sensor selectable for salt or fresh water Connection option for a Redox sensor Connection option for 2 level sensors 5 expa...

Страница 4: ...o not use force to plug in Important A false connection e g plugging in a light bar plug into a powerbar socket can lead to a destruction of the ProfiLux A possible repair is no warranty case and ther...

Страница 5: ...selection switch 6 in order that the conductivity is measured correctly The control cables of dimmable lamps light bars hanging lamps moonlight etc or controllable current pumps are plugged into the...

Страница 6: ...ox has two light emitting diodes 17 18 on the rear side for the status display not available on some devices The state LED 17 is the lower one the communication LED 18 is above Display Meaning State L...

Страница 7: ...ning the resources are ordered in the ProfiLux in the following manner The numbering starts in every case with the internal resources of the ProfiLux followed by the resources of the module cards inst...

Страница 8: ...2 Conductivity S 2 and Redox 2 are the internal sensor inputs of the first found by ProfiLux Expansion Box Airtemperature 1 and Humidity 1 originate from the PLM Humidity Temp in this Expansion Box L...

Страница 9: ...ards in the slots of the Expansion Box Thereafter the interfaces of the second Expansion Box follow and so on Example In case of a ProfiLux 3 with a PLM 4L card and an Expansion Box with a PLM 4L the...

Страница 10: ...ssigning the devices Only if all sensors and interfaces are checked and correctly assigned again the disabled devices can return to in operation again 3 6 The switching outputs of the Expansion Box Th...

Страница 11: ...here the PLM 2L4S at the Expansion Box Here only the switching outputs from S1 to S16 are available the others are free Attention During assigning devices it is also possible here that the numbering...

Страница 12: ...the module If you do not like to do the installation by yourself we can do this for you for a low charge possibly together with a firmware update Hint In the last slot Modul 4 only analog measurement...

Страница 13: ...nsert the module The new module can be inserted into any slot except slot Modul 4 slot nearest to the housing This slot only supports analog measurement cards at the moment When you insert it pay atte...

Страница 14: ...ection We assume no liability for direct damages indirect damages consequential damages and third party damages as far as it is legally permitted We do not take over guarantee that our product package...

Страница 15: ...voltage 12 VDC Power consumption 200 mA pH measurement BNC input for pH sensors accuracy 0 1 pH measurement range 3 0 pH to 10 5 pH Temperature measurement Mini DIN socket for delivered temperature s...

Страница 16: ...Bedienungsanleitung As of 04 20 2010 Seite 16 16...

Отзывы: