The filter sponges can be washed in
warm water and must only be replaced
once they are completely dry; if too dirty,
replace them with new ones.
- Reassemble everything in reverse order
of disassembly.
SPARE PARTS
Code
Description
M Class
2512741
Cartridge Filter
■
6620000
Canvas Filter (FD 36.1)
■
6730000
Canvas Filter (FD 50.1)
■
6830031
Fleece Filter Bag
6010540
Flexible Hose Ø29 - 5m
■
6010545
Flexible Hose Ø29 - 5m Combi
■
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
The vacuum cleaner does not
work.
Switch not pressed.
Press the Motor switch to
“ON” and ensure the Tool
switch is set to “MAN”.
Plug not inserted.
Insert the plug into the sock-
et.
No current.
Check the power supply line.
Suction is not satisfactory.
Fleece bag full.
Replace the dust bag.
Container full.
Empty container.
Filter elements clogged.
Clean the filter components.
Clean or replace the class M
cartridge filter.
Accessories or tubes
clogged.
Check and clean the flexible
hose and the suction nozzle.
Suction nozzle squeegee
worn or damaged.
Check and replace the
squeegee.
Checking the floater
- Remove the top as shown above.
- Check If the floater (37 Fig. 24) is In
good condition and if it moves freely in its
space.
- Reassemble everything in reverse order
of disassembly.