www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
ENGLISH
- 5
USING THE APPLIANCE
- The device is equipped with wheels and
thus can be moved with the proper han-
dles, or it can be pushed with the help of
the handle (21 Fig. 10).
- To lift it up insert your fingers under the
dedicated handle (22 Fig. 11) on the top
of the cover.
Starting the appliance as a dust
suction device or liquid suction
device
- Insert the plug (23 Fig. 12) into the sock-
et.
- Position the Tool switch (26 Fig. 13) to
“MAN”.
- Push the Motor switch (24 Fig. 13) to
“ON” to start the suction motor – the
switch will illuminate.
NOTE:
When the recovery tank is full, the noise
intensity increases and the device can no
longer aspire. Then you must switch off the
device and empty the tank as described in
the relevant paragraphs.
DANGER:
During functioning, always check
that the manometer hand (25 Fig.
10) remains in the green sector. If
the hand moves in the red zone it
means that it’s necessary to clean
or replace the filters.
Starting the appliance with tools
Manual start-up
- Position the Tool switch (26 Fig. 13) to
“MAN”.
- Push the Motor switch (24 Fig. 13) to
“ON” which will illuminate. The vacuum
cleaner starts up.
Automatic start-up
- Position the Tool switch (26 Fig. 13) to
“AUT”.
- Push the Motor switch (24 Fig. 13) to
“ON”, which will illuminate. The vacuum
cleaner starts-up when the tool connect-
ed starts and stops a few seconds after
tool switch-off.
Filter-shaker
For machines supplied.
- Remove the suction hose as described in
the relative paragraph.
- Start the suction motor.
- Use one hand to block the suction nozzle
(9 Fig. 14) and use the other hand to
open the hatch (27 Fig. 14) for one - two
seconds.
- Repeat the procedure 3 times and then
switch the suction motor off.
Switching off the appliance
- Push the Motor switch (24 Fig. 13) to
“OFF” to switch off the appliance – the
light switches off.
- Remove the plug (23 Fig. 12) from the
electrical socket.
- Wind up the cable (28 Fig.15) and hook it
onto its housing (29 Fig. 15).
CLEANING AND
MAINTENANCE
DANGER:
Before performing any mainte-
nance operation, unplug the ap
-
pliance from the electrical socket.
DANGER:
These operations can be per-
formed, in accordance with the
current laws, only by specialized
and trained personnel, while wear
-
ing the necessary safety clothing.
Manuale POWER TOOL M_8050855_2ed_11-2020.indd 5