46
10
Functional description
X: 24 VDC voltage supply
Connection of external devices such as photo cell, radio receiver, relay, etc. via the 24 V and
GND terminals.
Attention – Damage to components!
Total current consumption of external devices: maximum 350 mA
X1: Mains supply of the control and supply of external devices
Mains supply of the control
Connection via the terminals X1/1.1 to X1/1.4 and PE.
Various mains supplies: 3 N~, 3~, 1 N~ for symmetric and asymmetric motors.
Note!
▶
Pay attention to the "Mains supply" and "Mains supply connection to control"
descriptions
Supply of external devices
Connection of external devices for 230 V, such as photo cell, radio receiver, relay, etc. via
terminals X1/1.8 and X1/1.9.
Note!
The mains supply of external devices using terminals X1 / 1.8 and X1 / 1.9
is only possible if the door control is connected to supply networks
with 3 N ~ 400 V or 1 N ~ 230 V (symmetrical)
Protection via F1, 1.6-A time-lag micro-fuse