59
11
Status display
Faults
Faults
Display: "F" and code
Code
Fault description
Fault causes and fault correction
Terminals X2.1 – X2.2 are open.
Slack-rope switch/Pass-door contact is open.
Check door safety switch.
Check whether the connection cable is
connected.
Open safety circuit (DES)
Emergency manual operation has been
activated.
Thermal protection of the motor has tripped
Check emergency manual operation. Check
door and door drive unit for stalling.
Warning! Danger of the door dropping!
Stalling may indicate the anti fall back
device (if incorporated) has activated.
Take appropriate measures.
Terminals X3.1 – X3.2 are open.
Emergency stop has been activated.
Check emergency stop.
Check whether the connection cable is
connected.
Radio transmission of WSD door-module is
faulty.
Radio channel assigned twice:
Use menu item 9.6 to read off the radio
channel. Use menu item 2.0 to manually
assign the radio channels.
Moisture in WSD door-module:
Replace WSD door-module und use a splash
guard (optional equipment).
Obstacle between WSD door-module and
door control:
Adapt fitting configuration or use a spiral
cable.
Battery voltage too low:
Read off voltage value using menu 9.6 and
replace battery if this is less than 3.2 V.
Red LED in WSD door-module:
Press P1 push-button.
Flashing: Faulty radio connection
Lit: Radio connection OK
Pay attention to the WSD door-module
manual