13. Troubleshooting
Display
Problem
Solution
-- -- -- --
Display timebase too large
Change
fl
ow timebase (S=Seconds, M=Minutes, H=Hours,
D=Days) in CALIBRATE menu to a smaller value (e.g. GPD to
GPM)
Check settings
for Relay X
Relay 1 or 2 pulse width too large for
frequency input or pulse volume too small
Reduce Relay 1 or 2 pulse width setting (sec. 9.2 I) or increase
pulse volume setting (sec. 9.2 H)
Check settings
for AUX output
Auxiliary output pulse width too large for
frequency input or pulse volume too small
Reduce auxiliary output pulse width setting (sec. 9.2 M) or
increase pulse volume setting (sec. 9.2 L).
Must be between
0.0001 - 99999
Relay 1, Relay 2, or Auxiliary output (AUX)
pulse volume setpoint must be within
0.0001 - 99999.
Enter volumetric setpoint within 0.0001 - 99999. engineering
units (sec. 9.2 H or 9.2 L)
Must be between
0.10 - 999
Relay 1, Relay 2, or Auxiliary output (AUX)
pulse width must be within 0.10 -
999 seconds
Enter pulse width within 0.10 - 999 seconds
(sec. 9.2 I or 9.2 M)
Flow K-Factor
can not be zero
Flow display K-Factor cannot be zero
Enter K-Factor greater than zero (sec. 9.2 C)
Total K-Factor
can not be zero
Totalizer K-Factor cannot be zero
Enter K-Factor greater than zero (sec. 9.2 E)
SETUP READ ERROR
Press any Key
Power fault occurred while saving setup
menu entry
Press any key to reload factory defaults then reprogram
fl
ow
system setup parameters.
Note:
Totalizer displays remain
unchanged and will resume after instrument reset.
14. Maintenance
Clean the instrument case and front panel with a soft cloth and mild liquid soap solution.