13. Troubleshooting

Display

Problem

Solution

-- -- -- -- 

Display timebase too large

Change 

fl

 ow timebase (S=Seconds, M=Minutes, H=Hours, 

D=Days) in CALIBRATE menu to a smaller value (e.g. GPD to 
GPM)

Check settings

for Relay X

Relay 1 or 2 pulse width too large for
frequency input or pulse volume too small

Reduce Relay 1 or 2 pulse width setting (sec. 9.2 I) or increase 
pulse volume setting (sec. 9.2 H)

Check settings

for AUX output

Auxiliary output pulse width too large for 
frequency input or pulse volume too small

Reduce auxiliary output pulse width setting (sec. 9.2 M) or 
increase pulse volume setting (sec. 9.2 L).

Must be between

0.0001 - 99999

Relay 1, Relay 2, or Auxiliary output (AUX) 
pulse volume setpoint must be within 
0.0001 - 99999.

Enter volumetric setpoint within 0.0001 - 99999. engineering 
units (sec. 9.2 H or 9.2 L) 

Must be between

0.10 - 999

Relay 1, Relay 2, or Auxiliary output (AUX) 
pulse width must be within 0.10 - 
999 seconds

Enter pulse width within 0.10 - 999 seconds
(sec. 9.2 I or 9.2 M)

Flow K-Factor

can not be zero

Flow display K-Factor cannot be zero

Enter K-Factor greater than zero (sec. 9.2 C)

Total K-Factor

can not be zero

Totalizer K-Factor cannot be zero

Enter K-Factor greater than zero (sec. 9.2 E) 

SETUP READ ERROR

Press any Key

Power fault occurred while saving setup 
menu entry

Press any key to reload factory defaults then reprogram 

fl

 ow 

system setup parameters. 

Note:

 Totalizer displays remain 

unchanged and will resume after instrument reset.

14. Maintenance

Clean the instrument case and front panel with a soft cloth and mild liquid soap solution.

Содержание Signet 5500

Страница 1: ...Double Insulated DC or AC power Contents 1 Power Connections 2 Compatible Sensor Wiring 3 Sensor Pulse Output Connections 4 Auxiliary Pulse Output Connections 5 Totalizer Reset Connections 6 4 20 mA...

Страница 2: ...t PNP source input 5500 Terminals External power supply 28 VDC max Other instrument Gnd Input NPN sink input Gnd AUX output N 5500 Terminals Signal output Signal ground 3 28 VDC External power supply...

Страница 3: ...wer is applied after the relay 2 setpoint is reached 6 4 to 20 mA Current Output Connections sec 8 4 4 20 mA 5500 Terminals 4 20 mA Fuse 1 8A Technical Notes 1 8 A fuse recommended customer supplied 4...

Страница 4: ...nsor also displayed on totalizer To enable the totalizer function the operator must set the relay or auxiliary pulse volume setpoint to 1 0000 sec 9 2 H 9 2 L Totalizer function ideal for external cou...

Страница 5: ...djustments ENTER OPTIONS sec 9 3 CALIBRATE sec 9 2 VIEW sec 9 1 2 seconds 5 seconds Press hold ENTER key for menu access Menu Displays A H Factory default displays shown A Flowrate and resettable tota...

Страница 6: ...disable hysteresis feature L Sets auxiliary output pulse volume setpoint 0 0001 99999 sec 8 2 Set to 1 0000 factory default to enable totalizer function sec 8 2 M Sets auxiliary output pulse width 0...

Страница 7: ...nds High 8 seconds also affects 4 to 20 mA output E Sets 4 mA output setpoint 4 mA and 20 mA setpoints are reversible F Sets 20 mA output setpoint 20 mA and 4 mA setpoints are reversible G Sets 4 mA c...

Страница 8: ...ilicone rubber Weight Approximately 500 g 18 oz Display Type Microprocessor controlled air core meter movement and backlit alphanumeric 2 x 16 LCD Update rate Flow 1s totalizer 200 ms Contrast User se...

Страница 9: ...96 mm 3 8 in RELAY 2 RELAY 1 ENTER 4 0 1 2 3 5 6 7 8 9 10 GPM Signet Monitor 92 x 92 mm 3 62 x 3 62 in Panel cutout Menu Parameters Display Description Range Factory Default A Flow rate and units Rese...

Страница 10: ...max _Gallons E Total K Factor 0 0001 99999 60 000 F Relay 1 mode Relay 1 setpoint Low or High 0 0000 99999 Pulse 0 0001 99999 Low 10 000 GPM G Relay 1 Hysteresis Hysteresis volume 0 0000 99999 2 0000...

Страница 11: ...l to D Display averaging Off 0 sec Low 4 sec High 8 sec Off E 4 mA setpoint Unlimited 0 0000 GPM F 20 mA setpoint Unlimited 100 00 GPM G 4 mA adjust 3 0 to 5 0 mA 4 00 mA H 20 mA adjust 19 to 21 mA 20...

Страница 12: ...mall Reduce auxiliary output pulse width setting sec 9 2 M or increase pulse volume setting sec 9 2 L Must be between 0 0001 99999 Relay 1 Relay 2 or Auxiliary output AUX pulse volume setpoint must be...

Отзывы: