TSA 160 NT and variants
4
Safety notices
1
Safety notices
1.1 Intended use
The TSA 160 NT swing door drives are designed for the automatic opening and closing of single action swing doors.
The above mentioned door drive is suitable:
à
solely for use in dry rooms
à
in entrances and indoor areas of pedestrian traffic on commercial premises and in public areas
à
in private areas
The TSA 160 NT / TSA 160 NT IS/TS door drive
à
may be used in escape and rescue routes
à
may
not
be used on fire or smoke protection doors
à
may
not
be used for potentially explosive areas
The TSA 160 NT F / TSA 160 NT F-IS door drive
à
is designed for use on fire doors or smoke protection doors
à
may be used on emergency exit doors
à
may
not
be used for potentially explosive areas
The TSA 160 NT Invers door drive
à
is designed mainly for use on escape route doors and RWA supply air doors
à
may
not
be used for potentially explosive areas
Any improper use such as permanent manual operation, as well as any modification to the product, is not permitted.
1.2 Safety notices
à
The mandatory installation, maintenance and repair work must be performed by properly trained personnel
authorised by GEZE.
à
The country-specific laws and regulations are to be observed during safety-related tests.
à
If unauthorised changes are made to the system, GEZE cannot be held liable in any way whatsoever for any
resulting damage, and the approval for use in escape and rescue routes ceases.
à
GEZE does not accept any warranty for combinations with third-party products.
à
Furthermore, only original GEZE parts may be used for repair and maintenance work.
à
The connection to the mains voltage must be made by a professional electrician. Perform the power connec-
tion and equipment earth conductor test in accordance with VDE 0100 Part 610.
à
Use an on-site 10-A overload cut-out as the line-side disconnecting device.
à
Protect the display programme switch against unauthorised access.
à
In compliance with Machinery Directive 2006/42/EC, a risk analysis must be performed and the door system
identified in accordance with CE Marking Directive 93/68/EEC before the door system is commissioned.
à
Observe the current status of directives, standards and country-specific regulations, especially:
à
ASR A1.7 “Directives for doors and gates”
à
DIN 18650 “Building hardware - Powered pedestrian doors”
à
VDE 0100; Part 610 “Erection of low-voltage installations”
à
Accident-prevention regulations, especially BGV A1 “General regulations” and BGV A2 “Electrical installati-
ons and equipment”
à
DIN EN 60335-2-103 "Safety of electrical devices for home use and similar purposes - Part 2-103: Special
requirements for drives for gates, doors and windows”
à
DIN 18263-4 “Building hardware - controlled door closing devices - Part 4: Automatic swing door operators
with self-closing function”
à
DIN 18040 “Barrier-free construction”
à
Accident-prevention regulations, especially BGV A1 "Principles of prevention" and BGV A2 "Electrical sys-
tems and equipment"
à
Observe the specified temperature range.
The product should be installed or incorporated in such a way that effortless access to the product is guaranteed
during any repairs and/or maintenance, and that any removal costs do not stand out of proportion to the value
of the product.