Installation
6.4 Extension TSA 160 NT F and TSA 160 NT F -IS
The TSA 160 NT F and TSA 160 NT F-IS automatic systems are automatic swing door drives with an integrated
hold-open device for fire protection doors, smoke protection doors and doors that should be self-closing (fire
barriers). They are part of a hold-open system.
à
The mechanical mounting sequence corresponds to that of the TSA 160 NT drive.
à
For electrical connection: see the wiring diagram.
6.5 Extension of the integrated closing sequence control TSA 160 NT -IS, TSA 160 NT F -IS,
TSA 160 NT Z -IS, TSA 160 NT IS/TS
If mounting plates are used:
X
Install the mounting plates and intermediate mounting plate on the frame or sash.
X
Install the swing door drive on the passive leaf.
X
Install the swing door drive (-IS) on the active leaf.
Installation variations
TSA 160 NT F-IS
DIN left
1
DIN right door
1
Route the Bowden cable close to the drives
With a distance "A" between the middle side parts of less than 130 mm, the Bowden cable (3) must be routed
diagonally over the motor. The retainer plate (2) (mat. no. 108736) has to be attached to the hydraulic unit (1) to
guide the Bowden cable.
X
Route the Bowden cable (3) diagonally over the
motor.
à
Hinge size B ≤ 1510 mm (TSA 160, 2-leaf)
à
Hinge size B ≤ 1329 mm (TSA 160/TS 160,
asymmetrical)
X
Lay the wire rope (1) in accordance with the
sketch (see above).
X
Break out the side parts (2) where marked.
2
2