Slimdrive SLT product family

10

Installation

Clamping the track with clamping strips

WARNING!

Risk of injury!

Unsecured components may fall when under load.

 

X

Remove the cap with side plate.

The track (3) is clamped to the mounting profile (1) using clamping strips (2) so that the track (3) is attached so as 

to be prevented from twisting.

 

X

Slide 7 clamping strips (2) between the 

mounting profile (1) and the track (3).

Post/rail version: 

 

X

Position inner 5 clamping strips (2) at the 

level of the inner posts and position others 

between them.

Wall and ceiling installation: 

 

X

Mount the cap with side plate (see pre-in-

stallation instructions).

 

X

Position one clamping strip (2) on the  

exterior of each mounting profile/track  

as follows:

 

à

Left at the transition between the cap 

and track, 

 

à

Right at an appropriate distance from the 

end of the track.

Mounting the cover

 

X

Disconnect the cover (2) at the disconnection 

point (3) from the residual piece (4).

 

X

Dispose of the residual piece.

 

X

If necessary. slide the cover (2) in to the 

mounting profile (1).

Содержание Slimdrive SLT

Страница 1: ...Slimdrive SLT Product family EN Installation and service instructions 192483 01...

Страница 2: ...the floor guide 11 5 4 Installing the moving leaf 12 5 5 Fitting the tooth belt 19 5 6 Setting the stop buffer 22 5 7 Installing cable guides 22 5 8 Fitting the transformer ground 23 6 Production test...

Страница 3: ...ersion 01 valid for Slimdrive SLT product family from date of manufacture 2021 1 3 Product liability In compliance with the liability of the manufacturer for his products as defined in the German Prod...

Страница 4: ...work must be performed by properly trained personnel authorised by GEZE The country specific laws and regulations are to be observed during safety technology tests If unauthorised changes are made to...

Страница 5: ...glass breakage Always only use safety glass Risk of injury due to sharp edges on the drive and door leaf Risk of injury during installation through freely moving parts 2 4 Environmentally conscious wo...

Страница 6: ...the girder section installation is described in the instal lation instructions Girder section with side panel The following drawings illustrate installation with ISO profile systems The IGG profile is...

Страница 7: ...r section 70717 ep04 Installation diagram Slimdrive SLT girder section lintel installation 70717 ep08 Installation diagram Slimdrive SLT self supporting girder section Lock M 70717 ep09 Installation d...

Страница 8: ...l protective earth connections X X Secure workplace against unauthorised entry X X Always work with a second person X X Use a stepladder or stepstool with test seal X X Keep inside area of track clean...

Страница 9: ...t side of the mounting profile 2 and transfer the cable feed through X X Remove the mounting profile X X Drill fastening holes 1 into the mounting profile X X Cut out mounting profile 2 in the marked...

Страница 10: ...ail version X X Position inner 5 clamping strips 2 at the level of the inner posts and position others between them Wall and ceiling installation X X Mount the cap with side plate see pre in stallatio...

Страница 11: ...ntersunk head screws 3 and 2 1 Countersunk screw for moving leaf left hand slide to open 2 Countersunk screw 3 Countersunk screw for moving leaf right hand slide to open 4 outside 5 inside 6 Angled fl...

Страница 12: ...ing leaves must be dismantled see installation instructions for moving leaves See the installation drawing for the moving leaf for the position of the bracket support distance x y and overhang Install...

Страница 13: ...nnecting arm and long driver X X Use 2 hexagon screws 5 to screw the long driver 6 to the inner left moving leaf torque 15 Nm X X Clamp the connecting arm 3 in place using 2 setscrews 4 torque 3 Nm In...

Страница 14: ...g the moving leaves WARNING Risk of injury caused by moving leaf falling over The moving leaves are very heavy X X At least 2 people should work together to set up the moving leaf WARNING Risk of inju...

Страница 15: ...leaf into open position approx 20 mm 6 2 5 2 X X Position suspension piece 2 on the track approx 20 mm from the centre axis of the long rope pulley 6 and clamp in position X X Thread in the wire rope...

Страница 16: ...and clamp tightly X X Undo the fixing screws of the clamping piece 3 while at the same time with the help of a screwdriver push the clamping piece 3 to the left and tighten the wire rope slightly X X...

Страница 17: ...t 1 Adjusting the inclination and level of the moving leaves X X Adjust the inclination and level of the moving leaves using the hex of the suspension bolts 2 Horizontal adjustment of the moving leave...

Страница 18: ...strip with brush into the moving leaf until it snaps into place see the assembly drawing for the Slimdrive SL moving leaf X X Mount the guide rails in the floor area see the assembly drawing for the S...

Страница 19: ...t 1 leaf X X Screw the toothed belt locking 2 on the short driver 1 torque 10 Nm 2 leaf X X Screw the toothed belt locking 2 on the short driver 1 torque 10 Nm X X Fix the toothed belt locking 1 on th...

Страница 20: ...h a way that a slot head screwdriver can be pushed between the sliding block and the motor gear unit X X Tighten the screw 1 torque 10 Nm X X Push the slot head screwdriver into the gap and lever it u...

Страница 21: ...an be locked and unlocked X X If necessary enlarge the drill hole X X Tighten screws 1 X X Adjust the locking guide 4 so that the tooth belt neither touches nor has too much clearance To do this loose...

Страница 22: ...setscrew 2 on the stop buffer 1 X X Slide the moving leaf to the open position X X Slide the stop buffer 1 on the roller carriages X X Tighten the setscrew 2 using the Allen key torque 3 Nm 5 7 Insta...

Страница 23: ...g rail 3 and track X X Check whether the setscrews of the earthing rail 3 penetrate the anodised layer of the track The transformer must be positioned according to the drawing so that it covers the tr...

Страница 24: ...uctor test in accordance with VDE 0100 Part 600 X X Remove the sheath of the mains cable 4 on a max of 40 mm 3 2 9 mm PE 9 mm max 30 mm 10 mm 4 X X Strip the mains cable 4 Sheath removal length 40 mm...

Страница 25: ...t locking mechanism optional 6 3 Mounting the cover suspension piece X X Insert the suspension pieces 1 for the cover catch cable into the front groove on the right approx 1 cm from the edge of the tr...

Страница 26: ...e mounted suspension pieces 1 of the cover 4 6 3 1 Fitting the cover earthing X X Knock the locating pin for the cover earthing 1 on the side of the earthing approx 30 mm into the upper screw duct app...

Страница 27: ...r fixing bracket 1 and fix on a sliding block using locking screw M6 x 16 hexagon socket locking screw torque 15 Nm X X Distribute the cover fixing brackets evenly on the track depending on the space...

Страница 28: ...de panels 2 until it latches in and ensure that it is also seated correctly in the area of the track and cable guides X X Check the correct position of the cover safety ropes 1 and the earthing wire T...

Страница 29: ...nd outputs and on commissioning please refer to the wiring diagram 6 6 1 Creating a log book X X Carry out a safety analysis X X Record installed options in the safety analysis for the operator 6 7 Di...

Страница 30: ...ase of wear or damage Rubber cable In case of wear or damage Pulleys for rubber cable In case of wear or damage After completing the maintenance work always execute the learning function for the door...

Страница 31: ...pulley and replace if necessary 8 2 Replacing roller carriage WARNING Risk of injury caused by moving leaf falling over The moving leaves are very heavy X X At least 2 people should work together to...

Страница 32: ...isconnect the door system from the 230 115 V mains supply on site before removing the PCB cover 1 and secure against being switched back on again X X You will find the fuse value on the wiring diagram...

Страница 33: ...tion 2 Connection to external safety systems which have been approved by the drive manufacturer 3 Low energy Note Several classes may be marked Safety on the automatic door system version installation...

Страница 34: ...r ground fitted 5 8 23 12 Ground connection established 6 3 1 26 13 230 115 V connection established 6 1 24 14 Cover earthing connected 6 3 1 26 15 Supports for cover installed 16 Cover safety ropes f...

Страница 35: ...Slimdrive SLT product family 35...

Страница 36: ...geze com www geze fr Hungary GEZE Hungary Kft E Mail office hungary geze com www geze hu Iberia GEZE Iberia S R L E Mail info es geze com www geze es India GEZE India Private Ltd E Mail office india...

Отзывы: