31
GEZE SecuLogic emergency exit system
7.1.4.1 Installation of the mains connection terminal and mains connection
1
2
3
3
4
X
Insert strain relief plate
into the mains connec-
tion terminal.
X
Connect earthing cable
to the mains connection
terminal.
X
Connect the primary side
of the power supply to
the mains connection
terminal.
X
Fit a split washer over the
M4 bolt for earthing.
5
6
7
9
8
10
Position the mains connec-
tion terminal in the housing:
X
Fit the PE contact of the
mains connection termi-
nal over the M4 bolt.
X
Fasten the strain relief
plate using screw and
support.
Connect PE contact to the
housing:
X
Position lock washer over
PE contact and fasten
with nut.
X
Route power supply
line through the rubber
grommet.
X
Strip wires.
Only strip wires so
far that sheath can
be clamped in the
strain relief.
X
Connect wires of the
power supply line to
the mains connection
terminal.
It is best to use
pointed pliers to
insert the wires into
the mains connec-
tion terminal.
24 V
11
12
X
Attach the power supply
in the housing in such
a way that the 24V side
(RD, BK) is facing the
emergency exit sign.
X
Secure the power supply
line using the strain relief.
X
Insert the tab connec-
tor of the earthing cable
on the front plate.
Содержание SecuLogic TZ 321
Страница 69: ...69 GEZE SecuLogic emergency exit system ...
Страница 70: ...70 GEZE SecuLogic emergency exit system ...
Страница 71: ...71 GEZE SecuLogic emergency exit system ...