5.5 Terminal box KL 220
Terminal box KL 220 offers 4 additional inputs and 6 additional outputs.
5.5.1 Power supply
Mains connection
Fixed connection (installation cable)
Power supply
230 V AC ±10%, 50 Hz
Power supply
NT19.2-24, 800 mA
Secondary voltage
(for external components)
24VDC (±5%), SELV
5.5.2 Installation
UP variant
in flush-mounted connection box,
107 x 107 x 57 mm (W x H x D)
AP variants
in AP housing,
113 mm x 113 mm x 58 mm (W x H x D)
5.5.3 Terminal assignment
F1
X3
30
2 1
X1
X2
RES
31 32 33 34 35 36 37 38
23
1 2
24 25 26 27 28 29
19
18
2
17
16
2
42
41
3
1
1
2
3
4
24
VDC
RD/BK
230V
AC
BU/BN
NT19.2-24
1
Sabotage contact
F1
Fuse 24 V
2
LED RD – operation
1.0 A, SMF 125 V, fast-acting, mat. no. 111789
3
Mains connection
RES
Reserve fuse F1
4
Mains connection terminals
X1
Supply, TZ 320,
Additional PE
X2
Additional PA
X3
Additional PA