IMPIANTO ELETTRICO - ELECTRICAL SySTEM - SySTèME ÉLECTRIqUE - ELEkTRISCHE ANLAGE -
INSTALACIóN ELéCTRICA - ЭЛЕКТРИчЕСКАЯ СИСТЕМА - ΗΛΕΚΤΡΙΚΗ ΜΟΝΑΔΑ -
电气设备
Impianto elettrico
Caratteristiche elettriche e limite di utilizzo dell’alimentatore:
- Input: 100-240 V ac, 50-60 Hz, 1,1 A
- Output: 5V dc, 3A (max)
- Temperatura di esercizio: -20°C ÷ 50°C
Caratteristiche elettriche LED RGBW e limite di utilizzo del faretto:
- RED - 50 lm typical @ 300 mA/Ta =25°C, ±10%
- GREEN - 20 lm typical @ 300 mA/Ta =25°C, ±10%
- BLUE - 60 lm typical @ 300 mA/Ta =25°C, ±10%
- WHITE - 80 lm typical @ 300 mA/Ta =25°C, ±10%
- Temperatura di esercizio del Led RGBW: -30°C ÷ +85°C
- Temperatura di esercizio del faretto: 0°C ÷ +45°C
- Potenza assorbita: da 7W a 15W a seconda del colore selezionato (con luminosità al 100%)
A
- CENTRALINA E TRASFORMATORE -
fornita in dotazione
(Installabile solo nella “zona di sicurezza”
Z3)
B
- TASTIERA DI COMANDO LUCE -
fornita in dotazione
(Installabile nelle zone Z1 / Z2 / Z3)
B
- TASTIERA DI COMANDO LUCE -
tipo punto luce tradizionale
(Installabile solo nella “zona di sicurezza”
Z3)
Cavo da “A” a “B”:
Lunghezza massima =
7 m
Sezione =
0.2 mmq
Poli =
6
Cavo da “A” a “C”:
Lunghezza massima =
8 m
Sezione =
0.5 mmq
Poli =
5
ATTENZIONE: é obbligatorio il collegamento ad un salvavita con corrente di intervento non
superiore a 30mA.
Electrical system
Electrical characteristics and limit of use of the power source:
- Input: 100-240 V ac, 50-60 Hz, 1,1 A
- Output: 5V dc, 3A (max)
- Operating temperature: -20°C ÷ 50°C
Electrical characteristics LED RGBW and limit of use of the spot:
- RED - 50 lm typical @ 300 mA/Ta =25°C, ±10%
- GREEN - 20 lm typical @ 300 mA/Ta =25°C, ±10%
- BLUE - 60 lm typical @ 300 mA/Ta =25°C, ±10%
- WHITE - 80 lm typical @ 300 mA/Ta =25°C, ±10%
- Operating pressure of the Led RGBW: -30°C ÷ +85°C
- Operating pressure of the spot: 0°C ÷ +45°C
- Absorbed power: from 7W to 15W according to selected color (with 100% luminosity)
A
- POWER UNIT AND TRANSFORMER -
supplied
(For installation only in the “safety area” Z3)
B
- LIGHT CONTROL KEYBOARD -
supplied
(For installation in the areas Z1 / Z2 / Z3)
B
- LIGHT CONTROL KEYBOARD -
like a traditional spotlight
(For installation only in the “safety area” Z3)
Cable from “A” to “B”:
Maximum length =
7 m
Section =
0.2 mmq
Poles =
6
Cable from “A” to “C”:
Maximum length =
8 m
Section =
0.5 mmq
Poles =
5
WARNING: the connection to the cutout box is mandatory with intervention current not higher
than 30mA.
Содержание 32855
Страница 30: ...30 Impianto elettrico Electrical system Syst me lectrique Elektrische Anlage Instalaci n el ctrica...
Страница 46: ...46 INSTALLAZIONE INSTALLATION INSTALLATION INSTALLATION INSTALACI N Fig 5...
Страница 51: ...51 INSTALLAZIONE INSTALLATION INSTALLATION INSTALLATION INSTALACI N Fig 84 mm 4 mm 4 mm 4 mm...
Страница 58: ...58 MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N...
Страница 61: ...61 MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N Fig 16 Fig 17 Fig 18...
Страница 63: ...63 MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N Fig 19 Fig 20 Fig 21 2 5 mm 4 mm 4 mm 4 mm 4 mm...
Страница 69: ...69 MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N CN...