44 

18.  Specifications 

Ports

 

Number

 

of

 

Ports

 

10

 

ports

   

8

port

 

Fast

 

Ethernet

 

10/100BaseTX,

 

IEEE

 

802.3at

 

PSE

 

2

port

 

Gigabit

 

Uplink

 

(1*TP,

 

1*SFP)

     

Performance

 

MAC

 

Address

 

4

 

K

 

Buffer

 

Memory

 

2.75

 

M

 

bits

 

Transmission

 

Method

 

Store

 

and

 

Forward

 

Transmission

 

Media

 

10BaseT

 

Cat.

 

3,

 

4,

 

5

 

UTP/STP

   

100BaseTX

 

Cat.

 

5

 

UTP/STP

 

1000BaseT

 

Cat.

 

5/5E,

 

6

 

UTP/STP

   

Filtering/Forwarding

 

Rates

 

10

 

Mbps

 

port

 ‐ 

14,880

 

pps

 

100

 

Mbps

 

port

 ‐ 

148,800

 

pps

 

1000

 

Mbps

 

port

 ‐ 

1,488,000

 

pps

 

Smart

 

Features

 

Port

 

Based

 

VLAN

 

10

 

Tagged

 

Based

 

VLAN

 

32,

 

VID

 

=

 

1~4094

 

IGMP

 

Snooping

 

V1

 

&

 

V2

 

Link

 

Aggregation

 

1,

 

Gigabit

 

ports

 

Quality

 

of

 

Service

 

(QoS)

 

High

 

&

 

Low

 

priority

 

queues,

 

802.1p

 

Security

 

Port

 

&

 

MAC

 

binding,

 

3

 

MAC

 

per

 

port

 

Port

 

Management

 

Port

 

State,

 

Speed/Duplex,

 

Flow

 

Control

 

Configuration,

 

Port

 

Mirroring,

 

Bandwidth

 

Control,

 

Broadcast

 

Storm

 

Control,

 

PoE

 

Administrator

 

Management

 

Web

 

Management,

 

Password

 

Protection,

 

Configuration

 

Backup/Restore,

 

Firmware

 

Upgrade

 

Mechanical

 

Characteristics

 

LED

 

Indicators

 

Per

 

Port:

 

Link/Act

 

PoE

 

Act/Status

 

Power

 

Electrical

 

Characteristics

 

Input

 

100

 

~

 

240

 

V/AC,

 

50

 

~

 

60

 

Hz

   

PoE

 

Power

   

Output

 

IEEE

 

802.3at

 

Compliant

 

Voltage,

 

Per

 

Port

 

Max.

 

30

 

watts

   

(8

 

Ports

 

at

 

Full

 

15.4

 

W

 

/

 

4

 

Ports

 

at

 

Full

 

30

 

W)

 

Max.

 

Power

 

Consumption

 

130

 

W

 

General

 

Dimensions

 

(H

 

x

 

W

 

x

 

D)

 

44

 

x

 

266

 

x

 

160

 

mm

 

(1.73”

 

x

 

10.47”

 

x

 

6.3”)

 

Weight

 

1.8

 

kg

 

(3.97

 

lb)

   

Operating

 

Temperature

 

0°C

 

~

 

45°C

 

(32°F

 

~

 

113°F)

 

Storage

 

Temperature

 

20°C

 

~

 

90°C

 

(

4°F

 

~

 

194°F)

 

Humidity

 

10

 

to

 

90%

 

RH

 

(non

condensing)

 

Standards

 

and

 

Regulatory

 

Standards

 

IEEE

 

802.3

 

10BaseT

   

IEEE

 

802.3u

 

100BaseTX

 

IEEE

 

802.ab

 

1000BaseT

 

IEEE

 

802.3z

 

1000BaseSX/LX

 

IEEE

 

802.3x

 

Flow

 

Control

 

IEEE

 

802.3ad

 

Link

 

Aggregation

 

Control

 

Protocol

 

IEEE

 

802.1Q

 

VLAN

 

IEEE

 

802.1p

 

Class

 

of

 

Service

 

IEEE

 

802.1D

 

Spanning

 

Tree

 

Protocol

 

IEEE

 

802.1w

 

Rapid

 

Spanning

 

Tree

 

Protocol

   

IEEE

 

802.3at

 

Power

 

Over

 

Ethernet

 

(PoE+)

 

Regulatory

   

CE,

 

FCC

 

Class

 

A

 

Note:

 Specifications are subject to change without prior notice. 

Содержание GV-POE0801

Страница 1: ...Multicam Digital GV POE0801 User s Manual GV PoE Switch POE0801 A Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use...

Страница 2: ...or omissions No liability is assumed for incidental or consequential damages arising from the use of the information or products contained herein Features and specifications are subject to change wit...

Страница 3: ...Web Configuration 8 5 User Login 10 6 Administrator 11 7 Port Management 17 8 VLAN Setting 22 9 Per Port Counter 27 10 QoS Setting 28 11 Security 31 12 Spanning Tree 33 13 Trunking 36 14 Backup Recov...

Страница 4: ...ll not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the users are e...

Страница 5: ...tion of installing it in a 19 cabinet with a rack mount kit or underneath a desk Key Features Interface z Number of Ports 10 Fast Ethernet 8 port 10 100BaseTX with IEEE 802 3at PSE Gigabit Ethernet 1...

Страница 6: ...urity Setting Port Security Port MAC Address Binding up to 3 MAC Address per port TCP UDP Filtering Protocol Port Filter for secure WAN Port z Spanning Tree Protocol Version Support Legacy Spanning Tr...

Страница 7: ...efore you start to install this switch verify your package that contains the following items 1 GV POE0801 x 1 2 AC Power Cord x 1 3 Screw x 8 4 Rack Mount Kit x 1 5 User s Manual CD x 1 6 GV POE0801 Q...

Страница 8: ...orts Important For combo uplink ports both RJ 45 Gigabit Ethernet port and Gigabit SFP port can be used at the same time The maximum cable length for RJ 45 Gigabit Ethernet is 100 meters For connectio...

Страница 9: ...se by The flat space should be clean smooth level and sturdy Make sure there is enough clearance around the switch to allow attachment of cables power cord and allow air circulation The last use twist...

Страница 10: ...he transmission distance wavelength fiber cable can meet your request The way to connect the SFP transceiver is to Plug in SFP fiber transceiver fist The SFP transceiver has 2 plug for fiber cable one...

Страница 11: ...r network and that every PC on this network can access the switch via the web browser Verify that your network interface card NIC is operational and that your operating system supports TCP IP protocol...

Страница 12: ...will appear next 4 Type the default user name and password admin If you can t login the switch the following steps can help you to identify the problem 1 Switch to DOS command mode and type the ipconf...

Страница 13: ...w the description to understand the procedure At first open the web browser type http 192 168 0 250 and then the users will see the login page Type the default ID and password admin and click OK to pa...

Страница 14: ...tion This page shows authentication configuration information Users can set new Username and Password in this page Figure 6 1 System IP Configuration This page shows system configuration including the...

Страница 15: ...manually configure the IP Address settings Select DHCP mode means the switch acts as the DHCP client and the switch will try getting the IP Address from the DHCP server Click Update to update the new...

Страница 16: ...AC Address Displays the unique hardware address assigned by manufacturer default z Number of Ports Displays number of ports in the switch z System Version Displays the switch s firmware version z Idle...

Страница 17: ...ration Figure 6 5 Note Loading default from the web interface does not include user name password and IP configuration If you want to restore default settings including IP user name and password you c...

Страница 18: ...ware update itself Click Yes to continue If not click Cancel Figure 6 7 The smart switch will erase the flash memory There is a self protection mechanism in the Boot Loader so the Boot Loader will kee...

Страница 19: ...s the Uploading process is starting Figure 6 9 After firmware is correctly uploaded the web page shows OK Click Continue to re login the switch Figure 6 10 Reboot Device Click Confirm button to restar...

Страница 20: ...e Being set as Enable the Speed Duplex mode Pause Backpressure TX Capability and Address Learning are negotiated automatically When you set it as Disable you have to assign those items manually Speed...

Страница 21: ...toring RX only TX only or both RX and TX traffic which come from the source port Users can connect the mirroring port to LAN analyzer or Netxray z Monitored Packets Pull down the selection menu to cho...

Страница 22: ...o configure z TX Rate Type the TX Rate value The value is range from 0 255 z RX Rate Type the RX Rate value The value is range from 0 255 z Speed Base Low step by 32 Kbps High step by 256Kbps for Fast...

Страница 23: ...speed 500 us for 100Mbps speed and 5000us for 10Mbps speed The excessive broadcast packet will be discarded For those broadcast packets incoming from the un selected port the switch treats it as the n...

Страница 24: ...E port out power status in this page and also enable or disable per port Figure 7 6 z Port The port number z Enable Enable PoE feature of the specific ports z Output Power The output power of the port...

Страница 25: ...witch physically VLAN Mode You may select the VLAN Mode of the switch Port based VLAN is for separating traffic only on this single switch There is no handover of network traffic within VLAN groups to...

Страница 26: ...e tag means the 802 1Q tag of the outgoing packet of the selected port will not be sent Use this setting for your Network Connections to PCs Only packets of the VLAN Group the Port is member of will b...

Страница 27: ...ce to configure names These are just for your reference Only the numbers are important Figure 8 5 Add Enter a VID select the VLAN member for this entry and then press the ADD button to add a VLAN entr...

Страница 28: ...port joins multiple VLAN groups the PVID is important to identify where the incoming traffic will be forwarded to For example Port 3 is the member of VLAN 100 and 200 PVID of it is 100 The traffic re...

Страница 29: ...D Source Port allows you to define the PVID After configured and selected clicking on Add to create the table and related port mapping The new group with its setting will be displayed at the bottom of...

Страница 30: ...unt z Collision Count Transmit packet This category shows the packets outgoing from the switch and the count of collision z Drop packet Receive packet This category shows the number of received valid...

Страница 31: ...entify such classes but they do not guarantee delivery as do quality of service QoS functions which are implemented in the network devices Priority Mode There are three priority modes available to spe...

Страница 32: ...Port Base The selected port equipped with High Priority The non selected port is Low priority A packet received by a high priority port is handled as a high priority packet VLAN Tag The switch follow...

Страница 33: ...s of Service for TCP UDP port number allows the network administrator to assign the specific application to a priority queue z F I F O The incoming packet will be forwarded in first in first out schem...

Страница 34: ...e MAC address to one specific port Figure 11 1 z Port No Displays the port number being assigned the MAC addresses z MAC Address Type the target MAC address you want to bind for the specific port User...

Страница 35: ...shown below negative means the selected protocol will be dropped and other protocols will be forwarded positive means the selected protocol will be forwarded and other protocol will be dropped z Prot...

Страница 36: ...have the same priority the device with the lowest MAC address will then become the root device Number between 0 61440 in increments of 4096 Therefore there are 8 distinct values z Hello Time Interval...

Страница 37: ...iority and Root Path Cost Click Submit to apply the settings Figure 12 2 z Port No The port ID It cannot be changed Aggregations mean any configured trunk group z Root Path Cost This parameter is used...

Страница 38: ...feature can help you leave the risk Figure 12 3 z Loopback Detection Function This column allows you to enable or disable Loopback Detection function z Auto Wake Up Once the Loopback Detection functio...

Страница 39: ...lure within the trunk group causes the network traffic to be directed to the remaining ports Load balancing is maintained whenever a link in a trunk is lost or returned to service This switch may use...

Страница 40: ...e the following parameters can be configured Noted that the parameters of the both ends of the LACP should be the same z Operation Key This column allows you to type operation key z Time Out This colu...

Страница 41: ...onfiguration The users can save configuration file to a specified file If the users want to recover the original configuration which is saved at the specified path just enter the password and then pre...

Страница 42: ...cation the multicast stream is continuously generating from the source port the client port may be congested because of the limited bandwidth or slow network processing ability Then the Pause frame of...

Страница 43: ...ure that allows the switch to listen in on the IGMP conversation between hosts and routers By listening also known as snooping to these conversations the switch maintains a map of which ports clients...

Страница 44: ...ext VLAN this packet will be forwarded to the uplink port Choose the Uplink Port X for the port ID The Uplink X will be the uplink port of its VLAN Note There is a functional conflict between VLAN str...

Страница 45: ...ll parameters governing the onboard agent Users should therefore assign a new administrator password as soon as possible and store it in a safe place After finished configuring the switch you can clic...

Страница 46: ...e switch Note After restoring default settings you will need to configure IP address ID and Password again To remain the set IP address ID and Password you can restore default settings using the web i...

Страница 47: ...Management Password Protection Configuration Backup Restore Firmware Upgrade Mechanical Characteristics LED Indicators Per Port Link Act PoE Act Status Power Electrical Characteristics Input 100 240 V...

Отзывы: