![GeoVision GV-FR Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/geovision/gv-fr/gv-fr_user-manual_2215832049.webp)
41
Chapter 7 Third-Party Controller Integration
GV-FR Panel is able to send access data to and integrate with third-party access systems
through Wiegand connection. There are two methods to connect GV-FR Panel to a third-
party controller: via onboard Wiegand interface and via optional GV-FWC face data converter.
Note:
Face images of recognition events cannot be sent to 3
rd
-party controllers through
Wiegand connection.
7.1 Via Onboard Wiegand Interface
Use the Wiegand port on GV-FR Panel, as indicated below, to connect with a 3
rd
-party
controller.
GV-FR Panel
-
Wiegand
3
rd
- party controller
Wiegand
Note:
If the third-party controller fails to respond to GV-FR Panel connected via its
Weigand interface, i.e, the access information received by GV-FR Panel
wasn’t transmitted
to the third-party controller, please prepare two resistors
of 3.3 or 4.7 kΩ, and apply the two
resistors to the Wiegand interface. One is between D0 and 12 V, and the other between D1
and 12 V, as illustrated below.