72
No. of Channels Connected to Center
V2 Server
Recycle Size (MB)
1 ~ 49
400
50 ~ 99
500
︴
︴
800 1500
Storage Group:
You can store the recordings of different subscriber
at separate locations using the storage group feature. For details, see
the following section
Storing Video Files in Separate Locations
.
Enlarge Path Threshold:
When the space in a storage path falls
short of the path threshold (500 MB by default), recordings are saved
to the next path of the same storage group. To enlarge the path
threshold, select this option and specify the path threshold. To add
paths, see the following section
Storing Video Files in Separate
Locations
.
Keep Days:
The recordings are stored for the specified number of
days before they are recycled.
Enlarge Recycle Threshold:
When the current storage path falls
short of the recycle threshold (800 MB by default), recycle starts. To
enlarge the recycle threshold, select this option and specify the
recycle threshold.