GeoSmart NETZERO BW B B Скачать руководство пользователя страница 43

 

Installer manual NETZERO

 

GEOSMART ENERGY 

43 

EN

 

3.2.

 

Power circuit diagram 

NETZERO 9 kW 

 

 

 

0

24

0

-5%

230

+5%

N PE

N PE

T1

T2

T1

T2

NO1

NC1

J16

C1

J18

Out3

C2

J19

Out4

C2

J20

Out5

C2

J21

C2

V-IN

J22

NO6

C6

J23

NO7

C7

J24

NO8

C8

NO9

C9

J27

NC9

NO10

C10

NC10

C11

NO11

J28

NO12

NO13

C11

J2

U2

U1

U3

GND

J3

U5

U4

+Vdc

+5VR

GND

J4

U7

U6

+Vdc

+5VR

GND

J25

DI7

DI7H

DI7C

DI8

DI8H

J5

U10

U9

+Vdc

+5VR

GND

U8

J6

Y2

Y1

Y3

GND

J26

U11

Y5

GND

U12

GND

Y4

DI9

DI10

DI9C

J7

DI3

DI2

DI4

GND

DI1

Tx/Rx -

Tx/Rx+

GNG

J29

pCOOEM-U2

pCOOEM-U11

pCOOEM-U12

pCOe-B1

pCOe-B2

pCOe-B3

pCOe-B4

pCOOEM-Y1

pCOOEM-Y2

pCOOEM-Y3

pCOOEM-Y4

pCOOEM-Y5

pCOOEM-DI1

pCOOEM-DI2

pCOOEM-DI3

pCOOEM-DI4

pCOOEM-DI7

pCOOEM-DI8

pCOOEM-DI9

pCOOEM-DI10

pCOOEM-GN

D

pCOOEM-Out3

pCOOEM-Out4

pCOOEM-Out5

pCOe-N

O1

pCOe-N

O2

pCOOEM-U5

pCOOEM-U6

pCOOEM-U8

pCOOEM-U9

GND

Tx/Rx+

Tx/Rx -

J3

NO4

C4

J8

NC4

NO3

C3

J7

NC3

NO2

C2

J6

NC2

NO1

C1

J5

NC1

B3

B4

J10

GND

+5VR

+Vdc

B1

B2

J9

GND

+5VR

+Vdc

J4

DI2

DI1

DI3

DI4

DIC1

PE

pCOOEM-N

O08

Lon

N PE

pCOe-DI1

pCOE-DI2

pCOe-DI3

pCOe-DI4

N PE

N PE

N PE

N PE

Lon

Lon

230 Vac

Lon

Lon

N

Lon

pCOOEM-U

4

pCOOEM-U7

pCOOEM-U

1

pCOOEM-U3

pCOe-N

O3

pCOe-N

O4

230 Vac 0 Vac

0 Vac

0 Vac

pCOOEM-U

10

DO11

DO14

DO16

DO17

DO15

DO1

DO2

DO3

DO4

DO5

DO6

DO7

DO8

DO9

PS

ESS

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8

DI9

DI10

DI11

DI12

AO4

AO5

AO3

AI4

AI5

AI6

AI7

AI8

AI1

AI10

AI9

AI11

AI12

AI3

AI2

AI13

AI14

AI15

AI16

pCOOEM-GN

D

pCOOEM-5VR

pCOOEM-5VR

pCOe-GN

D

0 Vac

24 Vac

0 Vac

24 Vac

230 Vac

Distribution

24 Vac

Distribution

J1

G0

G

J1

G0

G

pCOe-Y1

AO6

0 Vac

24 Vac

pCOOEM-5

VR

pCOOEM-5VR

AO2 AO1

Y1

VG0

VG

J2

pCOOEM-Out2

DO10

J17

Out2

C2

N PE

Lon

DO12

N PE

Lon

DO13

230 Vac

230 Vac

230 Vac

DO8

TRAFO 

230/24

L2/N

L1

GND

Tx/Rx+

Tx/Rx -

J9 FB

US1

Vout

N

L

DCV

K1

A1

A2

VRI

TRI

Control Supply

230 Vac

Note

USE COPPER SUPPLY WIRES

Low voltage wires (

Aixx, Dixx

, Aoxx) are class 2

pCOOEM-GN

D

GND

Tx/Rx+

Tx/Rx -

J11 B

MS2

GND

Tx/Rx+

Tx/Rx -

J14 pLAN

0.5A

2.5A

L1

L2/N

EH1

L1

L2/N

EH1

L1 EH1

Heater Supply

L2/N

o

+

-

L1
L2

Drive Supply 

230V

Fus

e i

nf

orm

atio

n

0.5

Am

ps

2.5

Am

ps

M

an

ufa

ctu

re

r

SI

BA

SI

BA

M

ode

l

70

-0

07

-3

3/0

.5

A

70

-0

07

-3

3/2

.5

A

Fu

se

 ra

tin

g [

A]

0.5

2.5

Vo

lta

ge

 [V]

25

0

25

0

Siz

e [

mm]

5x

20

5x

20

Bre

aki

ng

 C

ap

aci

ty C

urre

nt A

C [

A]

15

00

15

00

Fu

se s

peed

F

F

Loff

Loff

PCOe

Loff

Loff

Loff

GND

Tx/Rx+

Tx/Rx -

J29

Sgn

Sgn

Sgn

Sgn

Sgn

Sgn

Sgn

Sgn 5Vdc GND

Sgn 5Vdc GND

Sgn 5Vdc GND

Sgn 5Vdc GND

Sgn

Sgn

Sgn

Sgn

Sgn

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

24 Vac

24 Vac

Vout GND

Vout

GND

Vout

GND

Vout 24Vac GND

Sgn Com

Sgn Com

Activación ACS

Sgn Com

Sgn Com

Sgn

24 Vac

Sgn

Sgn

Sgn

24Vac

24Vac

Sgn

Sgn

Sgn

Sgn

Vout 24Vac GND

Vout GND

24 Vac

24 Vac

24 Vac

24 Vac

24 Vac

24 Vac

24 Vac

Lon

N PE

Lon

N PE

Lon

N PE

Lon

N PE

Lon

N PE

230 Vac

230 Vac

PE

Lon

Lon

pCOOEM-N

O10

pCOOEM-N

O13

pCOOEM-N

O6

pCOOEM-N

O12

pCOOEM-N

O11

pCOOEM-N

O7

pCOOEM-N

O1

 

pCOOEM-N

C1

0Vac -24

pCOOEM-N

C9

pCOOEM-N

O9

pCOOEM-N

C10

0 Vac

0Vac -24

Inve
rter – HP-1

Inve
rter – HP-2

Lon

N

Lon

N

Lon

N

TRI

COMP

J12 VExp1

VExp

Содержание NETZERO BW B B

Страница 1: ...TECHNICAL SERVICE MANUAL EN NETZERO BW MODEL SERVICE CONTACT NETZERO CW...

Страница 2: ......

Страница 3: ...he cooling system 23 2 6 Configuration of the DHW production service 26 2 7 Configuration of the pool service 26 2 8 Configuration of production priorities 27 2 9 Activation of special programs 27 2 1...

Страница 4: ...ove through the various user menus and to adjust the parameters Figure 1 1 Control panel The general functions and operation of each of the buttons are indicated below The ALARMS menu can be accessed...

Страница 5: ...e activated A consumption bar is also shown for the compressor and modulating circulator pumps Aerothermal fan activated Source pump activated Compressor in start up phase Compressor activated Compres...

Страница 6: ...to the pool production exchanger and adjusts the power supply The outlet temperature and flow are constantly controlled to optimize installation performance This mode is activated when the heat pump...

Страница 7: ...ted Only for reversible heat pumps Wait Compressor start up is deactivated due to standby between start ups 15 minutes The minutes remaining for the compressor to start up are shown next to the icon S...

Страница 8: ...lfilling any SG state SG1 Normal status The heat pump operates normally according to their configuration SG2 Reduced tariff We are in a reduced tariff period so we will take advantage of the lower pri...

Страница 9: ...he heat pump is in emergency status due to an active alarm The compressor cannot be started up but the services can be attended to if there is an auxiliary unit enabled for emergency situations EMERGE...

Страница 10: ...gure 1 3 Browsing through the list of user menus XXXXXX XXXXXX XXXXXX 06 11 2016 Mon 14 25 1 7 5 1 User menu 1 9 On Off Schedule Heating User menu 2 9 On Off Programming Heating User menu 3 9 Schedule...

Страница 11: ...go to the previous or next screen or to return to the list of user menus Figure 1 4 Adjusting comfort parameters 1 9 ON OFF Menu On Off Shows the direction of the unit Used to switch the heat pump on...

Страница 12: ...NG AND POOL services Holiday calendar This can be used to program up to 3 periods a year when the heat pump stays on or off User menu 2 8 On Off Programming Heating Programming 1 4 a Date time b Sched...

Страница 13: ...he outlet temperature by 2 C Interior terminals Used to show and adjust the inside environment temperature setpoint Tcons and the comfort temperature differential DTc of the terminals of each outlet u...

Страница 14: ...outlet unit If the heat pump is in the COMBINED program it can also be used to show and adjust the temperature switch differential DTsw between HEATING and COOLING modes Auxiliary X cooling Used to en...

Страница 15: ...minutes hours that the heat pump is dedicated to the POOL mode when there are simultaneous demands for heating and pool during the WINTER program The icon indicates that there is a time schedule activ...

Страница 16: ...als assigned to each outlet unit Heating buffer Cooling buffer This shows the setpoint temperature the start up temperature differential and the current temperature of the buffer storage tank There ar...

Страница 17: ...tion regarding the current state of the consumption limit control the instantaneous consumption measurement and the setpoint for consumption limitation Press to access the e Manager meters It includes...

Страница 18: ...n This shows information about the application installed in the controller 1 17 ALARMS Menu Press for quick access to the information menu from the main screen Active alarms These screens display the...

Страница 19: ...Language 2 Configuration 2 1 Heat pump model 2 2 Source 2 3 Services 2 3 1 Heating 2 3 2 Cooling 2 3 3 DHW 2 3 4 Pool 2 3 5 Priorities 2 3 6 Special programs 2 4 e Manager 2 5 Auxiliary equipment 2 4...

Страница 20: ...re enabled Aerothermal collector 1 Used to adjust the difference in air antifreeze agent target temperatures to control the fan 2 Used to adjust the maximum fan percentage allowed 3 Used to adjust the...

Страница 21: ...roduced 3 Used to enable use of the heat pump to produce heat Heating units 1 Used to enable the outlet units in heating mode 2 Used to select the modulating valve control logic of the combined outlet...

Страница 22: ...emperature based on the indoor temperature 0 No indoor temperature offset 0 5 Correction of the outlet temperature equal to half the difference between actual and setpoint temperature 1 Correction of...

Страница 23: ...r setpoint This is the setpoint in case of surplus for the SG states 2 5 Configuration of the cooling system Active cooling 1 Used to enable the active cooling service 2 Used to select the type of con...

Страница 24: ...terminals must be configured with the addresses displayed on this screen NOTE This configuration is associated to the heating and cooling services If a bus terminal is enabled for an outlet unit in a...

Страница 25: ...useful in cases where collection must be performed at a different temperature than use or when an intermediate exchanger is installed between production and use 3 Used to set a minimum production tem...

Страница 26: ...Used to adjust the target outlet temperature in pool mode Also used to set the request logic of the pool 3 Used to enable use of the production circulator pump for the pool service Connection type 1 U...

Страница 27: ...d meter Used to select the address of the meter in the communication network and the type of installation single phase 1 phase or three phase 3 phases NOTE The default meter address is 100 If you chan...

Страница 28: ...ent can be used at the same time If the outlet temperature remains below the target within a range higher than the starting temperature difference and during at least the established starting time the...

Страница 29: ...the USER level its use must be enabled as SUPPORT and or EMERGENCY for the heating DHW and or pool services Note If it is enabled for DHW it will also be used for the LEGIONELLA PROTECTION programs I...

Страница 30: ...ut production surpluses can still be used by activating or deactivating the non critical loads configured SG4 1 1 Forced status The heat pump will force the maximum possible consumption in the install...

Страница 31: ...lished as USER and if there is no higher priority service with a request BMS remote control 1 Used to enable remote control via BMS or BMS FBus2 communication ports through ModBus protocol Note To acc...

Страница 32: ...ion 1 Used to adjust the maximum and minimum temperature of the source circuit If any of the limit values are reached the source temperature alarm is activated 2 Used to set the minimum pressure of th...

Страница 33: ...f you are not sure of the freezing temperature of the fluid used check it with a refractometer Compressor delay 1 Used to adjust the duration of the compressor switched on delay Note The compressor sw...

Страница 34: ...f operation number of start ups and start up hour ratios It also shows the current temperature of the compressor inverter AI Values This shows the current measured value at all analog inputs DI Status...

Страница 35: ...g 2 18 Default values Initialization 1 Used to delete the settings in the USER and INSTALLER menus and restore default factory settings DO Status DO1 Off DO8 On DO2 Off DO9 On DO3 On DO10 Off DO4 On D...

Страница 36: ...ng the configuration Note This option is only available for heat pumps with Danfoss compressors 2 19 Change password New password 1 Used to change the password to access the INSTALLER menu PW1 Energy...

Страница 37: ...e cooling defrosting exchanger 37 Source pressure transducer 11 Compressor 38 Production pressure transducer 12 Electronic expansion valve 39 Discharge mini pressure switch 13 Filter dryer 40 Service...

Страница 38: ...40 30 T 11 6 5 2 1 3 4 12 8 7 16 15 26 29 31 32 33 34 38 23 24 13 P 35 36 P 39 P 19 21 10 9 44 T T T T T 27 43 25 22 17 P 28 T 18 20 37 P 40 40 14 30 T 11 6 5 2 1 3 4 12 8 7 16 15 26 29 31 32 33 34 38...

Страница 39: ...Installer manual NETZERO GEOSMART ENERGY 39 EN NETZERO BW 10 13 12 14 35 5 6 16 11 36 39 7 19 22 24 23 45 2 29 1 4 9 26 38 25 20 40 40 42 42 28 27 8 18 43 15 17 21 37 30...

Страница 40: ...9 31 32 33 34 38 23 24 13 P 35 36 P 39 P 19 21 9 44 T T T T T 43 25 22 17 P T 18 20 37 P 40 40 30 T 4 3 2 1 52 51 53 T 50 49 47 46 48 11 12 8 7 16 15 26 29 31 32 33 34 38 23 24 13 P 35 36 P 39 P 19 21...

Страница 41: ...1 32 33 34 38 23 24 13 P 35 36 P 39 P 19 21 9 44 T T T T T 43 25 22 17 P T 18 20 37 P 40 40 14 30 T 4 3 2 1 51 53 T 50 49 47 46 48 52 11 12 8 7 16 15 26 29 31 32 33 34 38 23 24 13 P 35 36 P 39 P 19 21...

Страница 42: ...ZERO 28 27 51 52 53 4 15 19 40 22 48 7 41 1 13 6 45 25 24 21 49 12 40 5 8 9 10 23 42 14 26 29 36 39 17 18 2 43 16 46 47 38 20 37 35 30 1 2 24 16 12 19 43 18 5 20 16 21 7 8 42 23 31 17 4 3 9 6 37 36 34...

Страница 43: ...15 AI16 pCOOEM GND pCOOEM 5VR pCOOEM 5VR pCOe GND 0 Vac 24 Vac 0 Vac 24 Vac 230 Vac Distribution 24 Vac Distribution J1 G0 G J1 G0 G pCOe Y1 AO6 0 Vac 24 Vac pCOOEM 5VR pCOOEM 5VR AO2 AO1 Y1 VG0 VG J2...

Страница 44: ...COOEM GND pCOOEM 5VR pCOOEM 5VR pCOe GND 0 Vac 24 Vac 0 Vac 24 Vac 230 Vac Distribution 24 Vac Distribution J1 G0 G J1 G0 G pCOe Y1 AO6 0 Vac 24 Vac pCOOEM 5VR pCOOEM 5VR AO2 AO1 Y1 VG0 VG J2 pCOOEM O...

Страница 45: ...ting buffer temperature Block I AI16 pCOe J10 B4 NTC 10K 25 C Cooling buffer temperature DIGITAL INPUTS CONNECTIONS DESCRIPTION Connection terminal Controller terminal Type Signal Block II DI1 pCOOEM...

Страница 46: ...Out4 Activation 230Vac 2A max Heating cooling consumption Block IV DO13 pCOOEM J20 Out5 Activation 230Vac 2A max Active cooling production Block IV DO14 pCOe J5 NO1 Activation 230Vac 2A max SG3 group...

Страница 47: ...kW NETZERO 22 kW NOTE Maximum speed of compressor is not able in all the areas of the operation map 25 10 25 40 7 65 35 65 35 10 5 10 15 20 25 30 35 40 45 50 55 60 65 70 30 25 20 15 10 5 0 5 10 15 20...

Страница 48: ...5 C Source temp 7 10 C Heating temp 50 55 C 0 0 5 1 1 5 2 2 5 3 3 5 4 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Electric input kW Compressor Speed Source temp 3 0 C Source temp 2 5 C S...

Страница 49: ...temp 2 5 C Source temp 7 10 C Heating temp 50 55 C 0 1 2 3 4 5 6 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Electric input kW Compressor Speed Source temp 3 0 C Source temp 2 5 C Source temp...

Страница 50: ...7 10 C Heating temp 50 55 C 0 1 2 3 4 5 6 7 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Electric input kW Compressor Speed Source temp 3 0 C Source temp 2 5 C Source temp 7 10 C Heating...

Страница 51: ...N NETZERO BW P NETZERO BW B NETZERO CW P NETZERO CW B 0 1 2 3 4 5 6 7 8 9 10 11 12 0 1 2 3 4 5 6 7 8 9 10 Passive cooling capacity kW DT T4 T2 C Flow Rate source Flow rate cooling 2000 l h Flow Rate s...

Страница 52: ...26 28 30 32 34 36 38 40 42 44 46 48 50 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 Pressure drop kPa Flowrate l h Evaporador Condensador Fr o pasivo Free cooling Evaporator C...

Страница 53: ...1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Pressure drop kPa Flowrate l h Condensador Evaporador Fr o pasivo Condenser Evaporator Free cooling 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80...

Страница 54: ...Installer manual NETZERO GEOSMART ENERGY 54 EN NETZERO 12 kW NETZERO 22 kW Grundfos UPML GEO 25 104 180 1 x 230 V 50 60 Hz PWM Grundfos UPMXL GEO 25 124 180 1 x 230 V 50 60 Hz PWM...

Страница 55: ...ETZERO GEOSMART ENERGY 55 EN 3 8 Production circulator pumps Main circulator pump NETZERO 9 kW Main circulator pump NETZERO 12 kW UPM2K 15 70 130 1 x 230 V 50 60 Hz PWM Grundfos UPM GEO 25 85 180 1 x...

Страница 56: ...Installer manual NETZERO GEOSMART ENERGY 56 EN Main circulator pump NETZERO 22 kW HTR system circulator pump Grundfos UPML GEO 25 104 180 1 x 230 V 50 60 Hz PWM UPM2 15 70 130 1 x 230 V 50 60 Hz PWM...

Страница 57: ...an be limited by the compressor discharge temperature 6 In compliance with EN 12102 this includes the acoustic insulation kit of the compressor 7 Start up intensity depends on the operating conditions...

Страница 58: ...pressure pre charge bar 0 5 3 1 5 Brine circuit pressure pre charge bar 0 5 3 0 7 Maximum ACS storage tank pressure11 bar 8 Working fluids Refrigerant type GWP R410A 2088 Charge T CO2 eq Kg ton 0 8 1...

Страница 59: ...ction circuit pressure pre charge bar 0 5 3 1 5 Brine circuit pressure pre charge bar 0 5 3 0 7 Maximum ACS storage tank pressure11 bar 8 Working fluids Refrigerant type GWP R410A 2088 Charge T CO2 eq...

Страница 60: ...roduction circuit pressure pre charge bar 0 5 3 1 5 Brine circuit pressure pre charge bar 0 5 3 0 7 Maximum ACS storage tank pressure11 bar 8 Working fluids Refrigerant type GWP R410A 1 4 R410A 1 5 Ch...

Страница 61: ......

Страница 62: ......

Страница 63: ......

Страница 64: ...dge ON N3C 0A5 T 1 866 310 6690 P 519 624 0400 F 1 866 533 3889 E info geosmartenergy com http www geosmartenergy com Technical service manual version 01 2022 The manufacturer reserves the right to ma...

Отзывы: