Installer manual NETZERO
GEOSMART ENERGY
13
EN
Peak / valley tariff for Winter / summer
This allows programming up to 4 time periods for each day of the week.
Independent time schedules can be set up for winter peak, winter valley, summer peak and
summer valley tariffs.
Temperature differential for winter / summer tariff
This allows configure the temperature differentials on the heat pump setpoint in the peak
and valley periods for each service in winter / summer period.
1.11.
HEATING Menu
Heating
This enables the HEATING mode and adjusts the heating cut-off temperature. The HEATING
mode is never activated for temperatures over the cut-off setpoint.
The
icon indicates that there is a time schedule activated in the HEATING mode.
Heating buffer
This shows the setpoint temperature of the buffer storage tank and allows adjustments to
be made to the start-up temperature differential.
Heating units
This can be used to adjust the heating target outlet temperatures programmed by the
technical service. Each ramp increases or decreases the outlet temperature by 2°C.
Interior terminals
Used to show and adjust the inside environment temperature setpoint (Tcons) and the
comfort temperature differential (DTc) of the terminals of each outlet unit.
If the heat pump is in the COMBINED program, it can also be used to show and adjust the
temperature switch differential (DTsw) between HEATING and COOLING modes.
Auxiliary X heating
This is used to enable the auxiliary heating system in both EMERGENCY and SUPPORT
mode.
In EMERGENCY mode, the auxiliary system is activated automatically when any of the
alarms are active.
In SUPPORT mode, the auxiliary system is activated automatically for normal HEAT
production, as programmed by the technical service.
User menu
2/8
On/Off
Programming
Heating
Programming
4/4
b.Schedule
c.Weekly schedule
d.Tariff Control
XXXXXX scheduler
Day:
Monday
1: 00:00
OFF
2: 08:00
ON
3: 10:00
OFF
4: 20:00
ON
Copy to:
ALL
XXXXXX tariff
Peak Valley
DHW:
-2
2 ºC
Heating:
-5
5 ºC
Cooling:
2
-2 ºC
Pool:
-5
5 ºC
User menu
3/8
Schedule
Heating
Cooling
Heating
Enable:
StopT:
16.0ºC
Heating buffer
SetT:
50.0ºC
DTstart:
5.0ºC
Heating groups
- 0 +
- 0 +
DG1:
SG2:
SG3:
SG4:
Room terminals
SetT
DTc
ºC
ºC
DG1:
20.0
2.0
SG2:
21.0
2.0
SG3:
22.0
2.0
SG4:
21.0
2.0
Auxiliary heating X
Emergency:
Support: