ELECTRONIC BOARDS
APPENDIX 5 - ELECTRONIC BOARDS
1 - MICROPRO POWER I/O BOARD
1.1 - Function
Controls the electric motor, the tightening cycles and communication (serial lines; parallel input and output links, field bus),
together with the storing of the results.
1.2 - Technical features
1.3 - Description
Plug-in board without front panel (size 220 x 233.35).
2 - - SERVODRIVE BOARD 8515
2.1 - Features
2.2 - Function
Controls autosynchronous 6-pole motors, equipped with a resolver type location sensor.
2.3 - Description
6U board, integrated in a shielded 12TE drawer and fitted with two 48-point connectors, type 41612 shape F.
Power supply:
5 V
DC
/ 300mA
Microprocessor:
Motorola 68332
Communication processor:
68302 (3 serial links)
flash EPROM:
512 ko
saved RAM:
1 Mo
Working voltage:
from 110 to 250 V
AC
Maximum current :
50 A
Installed power:
single-phase: 1,8 kW
Protections:
ceramic quick-acting fuse 20A (6.3x32)
excess current 60A
integrated differential circuit-breaking
Содержание CVIS II
Страница 8: ...6159932410 02 English 8 76 SAFETY INSTRUCTIONS...
Страница 12: ...6159932410 02 English 12 76 DESCRIPTION AND OPERATION...
Страница 18: ...6159932410 02 English 18 76 INITIAL START UP...
Страница 28: ...6159932410 02 English 28 76 RESULTS...
Страница 48: ...6159932410 02 English 48 76 CONNECTIONS AND INSTALLATION...
Страница 66: ...6159932410 02 English 66 76 CYCLE FLOWCHART AND TIMING CHART...
Страница 74: ...6159932410 02 English 74 76 PARTS LIST...