![Georges Renault CVIS II Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/georges-renault/cvis-ii/cvis-ii_operators-manual_2215373037.webp)
6159932410-02
English
37 / 76
MAINTENANCE
3.5 - Operating problems due to wear or breakdown
Symptoms
Possible causes
No
.
Check
The tool does not start whether in
tightening, or run reverse mode.
The screen is idle.
The controller is switched off
11
Check:
• the condition of the On/Off switch of the con-
troller.
• that the mains voltage on the input side of the
controller is not null.
• the condition of the controller fuses.
The tool does not start whether in
tightening, or run reverse mode.
MESSAGE: "Tool fault"
The tool has been changed.
12 The "Tool fault" message is displayed. You must
read the parameters of the new tool. If validating
the new tool does not correct the problem, check
the following points:
Note: Following a tool change, it is recommen-
ded NOT to update the transducer unbalance and
compensation values and to keep the ones saved
in the memory tool. This task should only be per-
formed after repairing or changing the transducer.
MESSAGE: E01
Missing Emergency stop connec-
tor or emergency stop button
engaged.
13 Check for links in the emergency stop connector
and check that the emergency stop button is not
engaged.
MESSAGE: "Tool fault"" (tool
link error)
The electrical links between the
controller and the tool are faulty.
14 The cable(s) is(are) not connected.
The connectors are insufficiently screwed or
inserted.
There are twisted contacts or contacts pushed
back in one of the connectors.
Check the continuity and insulation of every elec-
trical link in the cables; change them if necessary.
Tightening report: "Srv"
Insulation defect, stop induced
by the differential circuit-brea-
king
15 Check that the "Differential" message is dis-
played correctly by pressing the Enter key twice.
In that case, look for the insulation defect: it
could be in the motor, in the cable or in the con-
troller.
MESSAGE: "None"
The tool trigger is faulty
16 Check that the cycle starts: a report is generated.
In the "Maintenance - Inputs/Outputs" menu,
check the switching of input no. 6. If there is a
fault, test the switch between 6 and D in the tool
connector (
≤
6
Ω
).
MESSAGE: "not ready" (blin-
king) (Control menu) or "servo-
drive error" (Channel Test menu)
Servodrive not ready:
Open thermal contact.
Could also result from a resolver
fault or a resolver link fault
17 Check the condition of the "thermal contact"
LED on the front side of the servodrive. If the
LED is lit, check the motor temperature and the
connections (if necessary).
Содержание CVIS II
Страница 8: ...6159932410 02 English 8 76 SAFETY INSTRUCTIONS...
Страница 12: ...6159932410 02 English 12 76 DESCRIPTION AND OPERATION...
Страница 18: ...6159932410 02 English 18 76 INITIAL START UP...
Страница 28: ...6159932410 02 English 28 76 RESULTS...
Страница 48: ...6159932410 02 English 48 76 CONNECTIONS AND INSTALLATION...
Страница 66: ...6159932410 02 English 66 76 CYCLE FLOWCHART AND TIMING CHART...
Страница 74: ...6159932410 02 English 74 76 PARTS LIST...