Geo Knight & Co warrants that the press is free from defects in both material and workmanship 

One Year from the date of invoice to the buyer. If any parts or workmanship are found to be defective in 

manufacture, Geo Knight & Co will repair or replace the defective parts or workmanship.  In addition, Geo 

Knight & Co warrants that the Digital Knight heat control is free from defects in both material & workmanship 

and is covered under no-charge support for (3) years. Geo Knight & Co also warrants that the heating 

element is warranted for the lifetime of the press, provided it is owned by the original purchaser. This lifetime 

warranty on the heating element does not cover temperature sensor failure, damage or disconnection. This 

warranty covers all parts to repair the defects, except when damage results from accident, alteration, misuse 

or abuse, or when the machine has been improperly installed, or modified in any way. If the press becomes 

defective during the limited warranty period of one year for the entire press, three years for the control, or 

the lifetime of the heating element, Geo Knight & Co reserves the right to recall the defective press to the 

factory for repairs if on site component replacement is deemed not possible by Geo Knight & Co. A return 

authorization must be granted by Geo Knight & Co prior to its return.

 

If a press covered by the one year limited warranty must be returned to the factory for repairs, 

Geo Knight & Co shall make every effort to repair buyer’s press. However, Geo Knight & Co reserves the 

exclusive right to determine whether to repair or replace a defective press. If Geo Knight & Co authorizes a 

replacement press, the warranty of the replacement press shall expire on the anniversary date of the original 

machine’s invoice to the buyer.

 

There are no warranties which extend beyond the description on the face hereof. Seller disclaims 

any implied warranty of merchantability and/or any implied warranty of fitness for a particular purpose, and 

buyer agrees that the goods are sold “as is”. Geo Knight & Co does not warrant that the functions of the 

press will meet the buyers requirements or expectations. The entire risk as to use, quality and performance 

of the press lies with the buyer. In no event will Geo Knight & Co be liable for any damages, including loss 

of profits, destruction of goods or any other special, incidental, consequential or indirect damages arising 

from the use of the press or accompanying materials. This limitation will apply even if Geo Knight & Co or 

its authorized agent has been advised of the possibility of such damage.

Limited Warranty

Содержание Digital Knight DK16

Страница 1: ...1 Version 1 09 Digital Knight DK20 16x20 and DK16 14x16 Digital Clamshell...

Страница 2: ...ing Programming a Preset 12 A Walkthrough Tutorial for using Presets 13 User Menus 14 Entering the user menus options 14 Fahrenheit Celsius 14 Timer Counter Units 14 Recorded Pressings User Odometer 1...

Страница 3: ...uccessful and easy as possible Please take the time now to thoroughly read through this manual to become acquainted with them It will explain some key features concepts and methods that will save much...

Страница 4: ...The height of the bench work space the press is located on would be ideally 27 to 32 high The higher the press the more difficult to close lock Attach the power cord from the rear to the backside of t...

Страница 5: ...set point temperature The right side of the screen will also indicate the timing status by stating OPEN TIMING or DONE The DONE indicator may remain on in some cases until the press is opened back up...

Страница 6: ...sed for 5 seconds before a main pressing cycle of 20 seconds the Prepress timer can be set for 5 secs and the main timer for 20 When the operator closes the press the 5 sec time counts down When the o...

Страница 7: ...k click clamp sound will result when locking the press in place To decrease the pressure turn the pressure knob to the right clockwise The top head will rise away from the lower table To increase the...

Страница 8: ...nge A good medium pressure for most applications would be 4 to 6 Excessively high pressure for demanding items would be 7 to 9 Digital Pressure Bar Graph The DK20 and DK16 are upgradable to an automat...

Страница 9: ...and reduce the life of the silicone pad When pressing rigid substrates plastics metals woods etc be sure that any protective films or laminates are removed before heating Always check that the transfe...

Страница 10: ...e that warns the operator of a possible thermal run away of the press This means the press relay may be locked in a heating position where it will never stop heating to a possibly harmful temperature...

Страница 11: ...urrent settings This is simply a reference a reminder of what pressure setting the operator must adjust for that preset Thereare2mainfunctionstousingthepresets LOADINGandEDITING the preset LOADING a p...

Страница 12: ...reset Press the TEMP key The Prepress time will flash Use the Arrow Keys to set the Prepress time Set the Prepress time to 00 if only one timer is to be used for that preset Setting Prepress to 00 wil...

Страница 13: ...re ref to 8 with the arrow keys Press TEMP Press PRG to leave the preset mode Presets SET 01 and SET 02 have now been programmed Part 2 Loading the presets Let s say we are powering on the machine and...

Страница 14: ...ature setting or preset modes may be activated instead Turn the press off and then on and try again Fahrenheit Celsius The current and set temperature can be displayed in F or C After entering the use...

Страница 15: ...e the arrow keys to reset the counter to 0 Press PRG to move to the next menu item Pressure Minimum To reset and redefine 0 for the pressure bar graph use this calibration menu Do NOT adjust this sett...

Страница 16: ...Press PRG to move to the next menu item Temperature Drop Sense The press can be set to alarm if the temperature drops a certain range below the set temperature This is useful to warn the operator if...

Страница 17: ...rent beeping patterns This can differentiate between multiple presses and allow the operator to have a short beep or a continuously repeating beep After entering the user menus see top of page 14 Pres...

Страница 18: ...e arrow keys to set it to ON or OFF Press PRG to move to the next menu item Prepress Timer The press can cycle back and forth between two distinct timer settings the normal countdown timer and a 2nd P...

Страница 19: ...e set to ON for this menu to be visible Use the arrow keys to set AL2 to OFF or 1 through 10 Press PRG to move to the next menu item denotes a short beep _ denotes a longer beep denotes infinite loop...

Страница 20: ...operation The pressure adjustment screw is an area of wear and stress on the machine and should be checked occaisionally for loss of threading Check the threads of the pressure screw and the pressure...

Страница 21: ...6 FAS AB38 3 8 X SOCKET HD SHOULDER SCREW FAS GB38U 3 8 ID X 3 4 OD 1 32 BRONZE WASHER FAS EL51618 5 16 18 ZINC TWO WAY LOCK NUT MEN 5162 QP 5 16 X 2 QUICK RELEASE PIN DKA CTRLC DIGITAL KNIGHT PROCESS...

Страница 22: ...22 Wiring Diagram...

Страница 23: ...r needs to be tilted downward towards the floor to signal the controller to start counting Second Check the wire connection from the tilt sensor into the control panel The timer pressure signals go to...

Страница 24: ...eir original force These hydraulic lifter springs are extremely easy to replace and are a surprisingly similar or even lower cost than conventional mechanical springs Contact the factory for replaceme...

Страница 25: ...ective press to the factory for repairs if on site component replacement is deemed not possible by Geo Knight Co A return authorization must be granted by Geo Knight Co prior to its return If a press...

Отзывы: