background image

Optima 300

SPR

OG

Technische Angaben ohne Gewähr © Genvex

1

2

3

4

6

5

7

9

8

10

10

1

Danmark - Dänemark - Denmark

Genvex A/S

DK - 6100 Haderslev
Tel.: +45 73 53 27 00
Fax: +45 73 53 27 07
E-Mail: [email protected]

2

Belgien - Belgium

Artiklima bvba

B - 9220 Hamme
Tel.: +32 (0) 52 41 25 41
Fax: +32 (0) 52 41 29 66
E-Mail: [email protected]

3

Storbritannien - 

England - Great Britain

Total Home Enviroment Ltd

GB- Moreton in March, GL 56 0JQ
Tel.: +44 (0) 845 260 0123
Fax: +44 (0) 1608 652490
E-Mail: [email protected]

4

Norge - Norwegen - Norway

Beam Sentralstøvsuger A/S

N - 1313 Vøyenenga
Tel.: +47 - 67 17 77 00
Fax: +47 - 67 17 77 10
E-Mail: [email protected]

5

Schweiz - Switzerland

SM-HEAG Klimatechnik AG

CH-8307 Effretikon
Tel.: +41 (0) 52 / 355 11 00
Fax: +41 (0) 52 / 355 11 05
E-Mail: [email protected]

6

Tyskland - Deutschland - 

 

Germany

Novelan GmbH

D-95359 Kasendorf
Tel.: +49 (0) 92 28 / 99 60 7-0
Fax: +49 (0) 92 28 / 99 60 7-189
E-Mail: [email protected]

7

Østrig - Österreich - Austria

J.Pichler Lufttechnik GmbH

    

A-9021 Klagenfurt
Tel.: + 43 (0) 463 / 3 27 69
Fax: +43 (0) 463 / 3 75 48
E-Mail: [email protected]

Genvex forhandlere - 

Genvex Vertreter - 

Genvex representatives:

8

Slovenien - Slowenien

     - Slovenia

Pichler & CO d.o.o.

2000 Maribor
Tel.: +  386/ (0) 2/460 13 50
Fax: +  386/ (0) 2/460 13 55
E-Mail: [email protected] 

9

Kroatien - Croatia

Pichler & CO d.o.o.

10000 Zagreb
Tel.: + 385/ (0) 1/ 65 45 407 
Fax: + 385/ (0) 1/ 65 45 409
E-Mail: [email protected] 

10

Irland - Ireland / N.I.

ECO Systems Ireland Ltd

Co. Antrim BT54 6PH
Tel.: (UK 028) (ROI 048) +44 2076 8708 
Fax: (UK 028) (ROI 048) +44 2076 9781
E-Mail: [email protected] 

www.genvex.dk

Содержание Optima 300

Страница 1: ...betjeningsvejledning Gebrauchsanweisung User Manual Optima 300 Varmepumpe W rmepumpe Heat pump Version 3 02 0107...

Страница 2: ...1 3 Betriebsmen 20 1 4 Wochenprogramm 25 1 5 Abtauschema 25 1 6 Spezielle Funktionen 26 1 7 Schema f r Sollwerte 27 2 Funktion 2 1 Steuerung Optima 300 28 2 2 Zus tzliche Funktionen 28 2 3 Betriebssic...

Страница 3: ...1 Supply T2 Room T3 Fresh air T4 Exhaust air T5 Before coil cooling T6 Coil cooling T7 Extract air T8 Antifreeze T9 Solar collector R1 Compressor R3 Pre heat R2 Supp heat R8 Cooling R5 Heat level 2 R1...

Страница 4: ...Min cooling ON To prevent the unit from starting to cool during the winter regardless of how high the room temperature is the set point may be adjusted to the desired minimum outdoor temperature befo...

Страница 5: ...g with the actual unit If the air volumes are set lower than the minimum requirement the heat pump will stop and only pre heated air will be blown from the heat exchanger into all rooms Units without...

Страница 6: ...the week Monday 1 Tuesday 2 Wednesday 3 Thursday 4 Friday 5 Saturday 6 Sunday 7 Clock hour 30 Clock minute 31 Change day 32 Change point Set point Operations menu Exit OK 0 29 Clock hour Adjust the se...

Страница 7: ...ust be set to 0 42 Antifreeze set If freezing water has been switched to ON the set point must be adjusted to the desired temperature at which the freezing water sensor is to stop the unit The tempera...

Страница 8: ...tage to change the temperature difference The difference may be set between 0 1 1 0 52 R9 function This relay may be used as follows If the setting is 0 the relay is off If the setting is 1 the relay...

Страница 9: ...urs Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Wednesday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Thursday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Friday Hours Minutes Le vel Red T2 1...

Страница 10: ...ontrast of the display can be changed by pressing the Info button while the program info screen is displayed Use the arrows to adjust up or down You can also enter menu 44 press OK and then hold the i...

Страница 11: ...20 Room supply extract 0 0 0 0 c 5 0 C 21 Airflow 1 SUP 40 0 100 22 Airflow 2 SUP 70 0 100 23 Airflow 3 SUP 100 0 100 24 Airflow 1 EXT 35 0 100 25 Airflow 2 EXT 55 0 100 26 Airflow 3 EXT 70 0 100 27 C...

Страница 12: ...will perform control in the same way as the electric re heating surface Defrosting When the temperature difference between the temperature upstream of the cooling surface and the temperature of the c...

Страница 13: ...frame and washed in warm soapy water Keep the filter diagonally so the water runs out The filter must not be wrung out or washed in dishwasher After two or three washes replace the flat filter Place...

Страница 14: ...here power in the electric outlet Is the heat pump disconnected through the clock program Has the high pressure switch been activated The cable between the controller and the panel is mounted Has the...

Страница 15: ...oller panel 0V 10V TX RX Motor Valve 24 VDC 0V 0 10V El heater 1 2 Kw Step1 Relay 2 Extra Cooling Upstream Coil 0 8 KW Relay 3 Magnetic valve Defrosting Relay 4 Relay outlet For extra print For El hea...

Страница 16: ...t Air Heat exchanger Supply Air T4 T5 T3 T6 T1 MA4 Compressor T7 Control panel High pressure switch T2 Fresh Air Evaporator cooling coil High pressure switch Condenser heating coil Heat exchanger MA4...

Страница 17: ...ject to Technical Modifications 830209G 160228 Optima 300 8 Flow diagram GE Mini Midi C High pressure switch MA4 Compressor Controller panel MA7 HP Supply air Exhaust air T2 T3 Fresh air Evaporator co...

Страница 18: ...8307 Effretikon Tel 41 0 52 355 11 00 Fax 41 0 52 355 11 05 E Mail info sm heag ch 6 Tyskland Deutschland Germany Novelan GmbH D 95359 Kasendorf Tel 49 0 92 28 99 60 7 0 Fax 49 0 92 28 99 60 7 189 E M...

Отзывы: