Transportation and Storage 

As a rule, the unit should be stored packaged in an upright 

position and without water. Transported with care and over 

short distances, the unit may be tilted to up to 45 °C. 

Transportation and storage may take place at temperatures 

between -20 and +70 °C.

Transportation with a Forklift Truck

When the heat pump is transported with a forklift truck, it 

must be placed on the provided base mount. Lifting must be 

conducted slowly. As the unit has a high centre of gravity, 

the unit must be secured so as not to topple during trans-

portation.

Transportation with a Sack Trolley

Secure the unit against slipping on the sack trolley. Do not 

use water pipe connections, etc. for transportation purpos-

es. Make sure that the sack trolley does not damage the 

cabinet and the connectors.

Unloading

To prevent damage, offload the unit onto a level surface. 

Directions/Safety Instructions

• The construction of the unit conforms to all EU regula-

tions (see also the CE certificate).

• Take measures against fire during maintenance work that 

has to do with opening the coolant circuit, in particular, 

when the work involves fire (soldering, welding, etc.)

• Before starting work on the unit, remember to always dis-

connect all electrical connections.

• When connecting the unit, observe all applicable laws and 

regulations.

• The water used must be potable grade. A reduction  

valve should be installed if the water pressure is high.

• All connections for potable water must be certified.

Note: Work should only be done by a certified contractor.

Product Description

Use

The Combi 185 is a combined ventilation unit and domes-

tic water heat pump which can be used for:

• Heating hot domestic water; 

• Ventilating a dwelling; 

• Supplementing the heating of the dwelling with heated 

supply air when the heat pump is not busy producing 

domestic hot water.

Description

The Combi 185 is a ready-to-connect unit whose most 

important components are: cabinet, tank, coolant, atmos-

phere and water circulation components as well as a 

control unit and regulating and monitoring unit. The unit 

can be connected to an internal heat exchanger with an 

area of 0.8 m2 which allows connection to an external 

boiler, a solar heating system, etc. In the heat pump, the 

Combi 185 utilises the residual heat in the extract air to 

either heat the supply air or to produce domestic hot 

water. 

The Combi 185 Unit can heat domestic water 

corresponding to a family's hot water needs all year 

round. The used and cooled air is expelled outside via the 

discharge duct. 

 

The tank has a built-in immersion stem which makes it 

possible to regulate temperature in the tank by sensors 

placed at the bottom and in the middle of the tank. The 

Combi 185 has an electric heating element installed in the 

tank which acts as a backup.

Содержание COMBI 185 BP

Страница 1: ...COMBI 185 BP INSTALLATION INSTRUCTIONS...

Страница 2: ...ater Sensor Anode 8 Electrical Installation 9 System Inspection and Fine Tuning 9 Optimal Fine Tuning of the System 9 Requirements to the Hot Water Circuit 9 Initial Operation of the Water Circuit 9 C...

Страница 3: ...erve all applicable laws and regulations The water used must be potable grade A reduction valve should be installed if the water pressure is high All connections for potable water must be certified No...

Страница 4: ...ed and as soon as the sensors detect a temperature drop in the tank The com pressor runs until the entire tank has once again reached the set temperature The Combi 185 will normally be able to satisfy...

Страница 5: ...relation to the existing water pressure and pressure loss The aspects of the installation that have to do with water must comply with the local HWS regulations The water pipes can either be made hard...

Страница 6: ...various connectors Fresh Air FRONT Discharge air Supply air Extract air Connecting Supply Air The ducting system leading from the unit to air injected in living quarters Connecting Extract Air The du...

Страница 7: ...tial of the units efficiency it is necessary to insulate the ducts properly Genvex recommends as follows Supply Air and Extract Air Ducts To minimise heat loss from the ducting system in cold lofts in...

Страница 8: ...ank is fitted with a 0 8 m2 heating coil The heat exchanger is enamelled externally The connection is 3 4 RG A sensor controlling external connections such as solar cells an oil burner or a wood burni...

Страница 9: ...7 turns depending on how close they are to the unit Optimal Fine Tuning of the System Use air measuring equipment Check that all 5 items in the section above have been carried out before performing t...

Страница 10: ...tional operational connection can be used if the function of the unit is to be supported by a wood burner or a solar collector installation Sensor T9 see the diagram on the next page measures the temp...

Страница 11: ...rne T5 T6 T8 T9 L8 Eksternt stop L9 Ikke i brug L10 Modulerende For Eftervarme L11 0 10V Motorventil Eftervarme 0 10V Ekstern bypass L16 Modbus L17 0 10V Udsugningsventilator 0 10V Indbl sningsventila...

Страница 12: ...air Sensor supply air External stop EC fan Extract air Blue Yellow EC fan Supply air Blue Yellow Control signal Motorvalve Reheating EC fan Extract air Power supply Motorvalve Reheating External Bypas...

Страница 13: ...2 Vv Varmespiral Kv T8 T7 T9 Solfanger T3 T4 T6 Betjeningspanel T5 T rrefilter Fordamper k leflade Indbl sning MA6 udligningsventil MA5 udligningsventil H jtryks pressostat Bypass T1 T2D T2S Compresso...

Страница 14: ...make sure that the maximum temperature of the do mestic hot water does not exceed 65 C and that the pres sure in the accessory heat exchanger does not exceed 3 bar Comply with all applicable local rul...

Страница 15: ...OPT 312 12 1 040384 Kompressorsamling 13 1 061014 Kompressor Large 13 1 061000 Kompressor small 14 1 045776 Anode Pos Qty Item number Description 1 1 069173 Bypass motor 2 1 045721 Heating element 3 1...

Страница 16: ...16 DECLARATION OF CONFORMITY The declaration of conformity can be found on our website www genvex com...

Страница 17: ...ilies At the same time our system is an important element when it comes to saving energy in homes and in society as a whole in fact you can recover up to 95 of the heat energy with a Genvex system All...

Отзывы: