background image

 

 

 11

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

3

3

4

4

4

4

4

4

4

4

4

5

5

5

6

6

6

7

7

7 8

8

8

L1

L2

L3

L6

L8

L11

H2

H3

H7

H6

H8

H9

H17

H16

ES960C

PE

PE

L17

A

B

Q

1=

 1.

6A

Q

2=

 2.

5A

H1

L4

Q3= 0.5A

Q4= 0.5A

Q1= H8,H9,H10,H11,

        H12,H13,H14,

        H15,H16,H17
Q2= H6,H7,H9
Q3= L1-L17
Q4= L1-L17
Q5= H4, H5

H4

H5

H10

H11

H12

H14

H13

H15

L5

L9

Q

5=

 6.

3A

L10

L16

C

D

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

3

3

4

4

4

4

4

4

4

4

4

5

5

5

6

6

6

7

7

7 8

8

8

L1 = Potentialfri indgang til ekstraudstyr:

        Hygrostat, Emhætte, CO2

L2 = Optima Display

L3 = Følerne T1,T3,T4,T7

L4 = Fugtføler P1

     = Behovsstyring B1

L5 = Føler T2S

L6 = Følerne T5,T6,T8,T9

L8 = Eksternt stop

L9 = Ikke i brug

L10 = Modulerende For / Eftervarme

L11 = 0-10V Motorventil

                     Eftervarme

          0-10V Ekstern bypass

L16 = Modbus

L17 = 0-10V Udsugningsventilator

          0-10V Indblæsningsventilator

A = LED blinker - Forsyning ok

B = LED blinker (20 sek. interval) - Kommunikation til Optima Display 

D = LED blinker - Modbus kommunikation

Q = Sikring

MV = Magnetventil

H1 = Nettilslutning 230 VAC

H2 = (R2) Varmtvands Elpatron 230VAC

H3 = (R3) On/Off  El-For/eftervarme 230VAC

H4 = (R1) Højtrykspressostat

H5 = (R1) Kompressor 230VAC

H6 = (R10) Motorventil eftervarme,

                   Ekstern Bypass 230VAC

H7 = (R10) Ventilator, udsugning 230VAC

H8 = (R12) Belimo CM230-F-R ON/OFF Bypass 230VAC

H9 = (R10) Ventilator, indblæsning 230VAC

H10 = (R4) MV Afrimning 230VAC

H11 = (R7) Ekstra køl 230VAC

H12 = (R5) MV Vandvarme drift 230VAC

H13 = (R5) MV Udligningsventil 230VAC

H14 = (R6) MV Rumvarme drift 230VAC

H15 = (R6) MV Udligningsventil 230VAC

H16 = (R8) Hjælperelæ 230VAC

H17 = (R9) Hjælperelæ 230VAC

Electrical diagram Optima 312 with ES 960 Print

DIAGRAMS

Содержание COMBI 185 BP

Страница 1: ...COMBI 185 BP INSTALLATION INSTRUCTIONS...

Страница 2: ...ater Sensor Anode 8 Electrical Installation 9 System Inspection and Fine Tuning 9 Optimal Fine Tuning of the System 9 Requirements to the Hot Water Circuit 9 Initial Operation of the Water Circuit 9 C...

Страница 3: ...erve all applicable laws and regulations The water used must be potable grade A reduction valve should be installed if the water pressure is high All connections for potable water must be certified No...

Страница 4: ...ed and as soon as the sensors detect a temperature drop in the tank The com pressor runs until the entire tank has once again reached the set temperature The Combi 185 will normally be able to satisfy...

Страница 5: ...relation to the existing water pressure and pressure loss The aspects of the installation that have to do with water must comply with the local HWS regulations The water pipes can either be made hard...

Страница 6: ...various connectors Fresh Air FRONT Discharge air Supply air Extract air Connecting Supply Air The ducting system leading from the unit to air injected in living quarters Connecting Extract Air The du...

Страница 7: ...tial of the units efficiency it is necessary to insulate the ducts properly Genvex recommends as follows Supply Air and Extract Air Ducts To minimise heat loss from the ducting system in cold lofts in...

Страница 8: ...ank is fitted with a 0 8 m2 heating coil The heat exchanger is enamelled externally The connection is 3 4 RG A sensor controlling external connections such as solar cells an oil burner or a wood burni...

Страница 9: ...7 turns depending on how close they are to the unit Optimal Fine Tuning of the System Use air measuring equipment Check that all 5 items in the section above have been carried out before performing t...

Страница 10: ...tional operational connection can be used if the function of the unit is to be supported by a wood burner or a solar collector installation Sensor T9 see the diagram on the next page measures the temp...

Страница 11: ...rne T5 T6 T8 T9 L8 Eksternt stop L9 Ikke i brug L10 Modulerende For Eftervarme L11 0 10V Motorventil Eftervarme 0 10V Ekstern bypass L16 Modbus L17 0 10V Udsugningsventilator 0 10V Indbl sningsventila...

Страница 12: ...air Sensor supply air External stop EC fan Extract air Blue Yellow EC fan Supply air Blue Yellow Control signal Motorvalve Reheating EC fan Extract air Power supply Motorvalve Reheating External Bypas...

Страница 13: ...2 Vv Varmespiral Kv T8 T7 T9 Solfanger T3 T4 T6 Betjeningspanel T5 T rrefilter Fordamper k leflade Indbl sning MA6 udligningsventil MA5 udligningsventil H jtryks pressostat Bypass T1 T2D T2S Compresso...

Страница 14: ...make sure that the maximum temperature of the do mestic hot water does not exceed 65 C and that the pres sure in the accessory heat exchanger does not exceed 3 bar Comply with all applicable local rul...

Страница 15: ...OPT 312 12 1 040384 Kompressorsamling 13 1 061014 Kompressor Large 13 1 061000 Kompressor small 14 1 045776 Anode Pos Qty Item number Description 1 1 069173 Bypass motor 2 1 045721 Heating element 3 1...

Страница 16: ...16 DECLARATION OF CONFORMITY The declaration of conformity can be found on our website www genvex com...

Страница 17: ...ilies At the same time our system is an important element when it comes to saving energy in homes and in society as a whole in fact you can recover up to 95 of the heat energy with a Genvex system All...

Отзывы: