background image

 

 

 12

Print ES 960 to Optima 312

1

2

1

2

H1

1
2

1
2

H2

1
2

1
2

H3

1
2

1
2

H6

1
2

1
2

H7

1
2

1
2

H9

1
2

1
2

H16

1
2

1
2

H17

1
2

1
2

L1

1
2
3
4

1
2
3
4

L2

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

L3

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

L6

1
2

1
2

L8

1
2
3
4

1
2
3
4

L11

1
2
3
4

1
2
3
4

L17

M1

M1

M2

M2

M3

M3

PE

PE

T1

T3

T4

T7

21
22
23
24

21
22
23
24

Optima Design

M5

1
2

1
2

L5

C

PE

R S

C

PE

R S

1
2

1
2

H4

1
2

1
2

H5

1
2

1
2

H10

1
2

1
2

H12

1
2

1
2

H14

1
2

1
2

H11

MA2

MA3

MA4

MA5

MA6

1
2

1
2

H13

1
2

1
2

H15

M5

LL
N

N

PE

PE

T5

T6

T8

T9

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

L10

T2S

3

2

1

3

2

1

H8

M6

1
2
3
4

1
2
3
4

L16

1
2
3
4

1
2
3
4

L9

1
2
3
4

1
2
3
4

L4

P1

B1

Mains connection

1x230VAC, L-N-PE

Max: 13A

Aux. relay R9

1x230V 50Hz

ONLY control current

Potential free input

for optional:

Humidistat, 

Extractor hood ,

CO2

Sensor, 

top hotwater cylinder

Sensor, exhaust air

Sensor, fresh air

Sensor, supply air

External stop

EC fan

Extract air

Blue

Yellow

EC fan

Supply air

Blue

Yellow

Control signal

Motorvalve

Reheating

EC fan

Extract air

Power supply

Motorvalve

Reheating

External Bypass

EC fan

Supply air

Electric immersion

heater 1000W

Electric Pre/re-heater

Max 1200W

Black

Black

White

White

High pressure switch

Compressor

External bypass

Extra cooling

1x230V 50Hz

ONLY control current

Soleniod valve

Water heating mode

Equalization valve

Water heating mode

Equalization valve

Room heating mode

Soleniod valve

Room heating mode

Soleniod valve

Defrost

Sensor

solar collector / option

Sensor, 

bottom hotwater cylinder

Sensor, evaporator

Sensor

before evaporator

Aux. relay R8

1x230V 50Hz

ONLY control current

Bypass

Belimo

CM230-F-R

ON/OFF

1

2

3

Modulating

Reheating

Modulating

Preheating

Sensor, extract air

Brown
Blue

Black

Not in use

Humidity sensor P1

White
Red/Brown
Blue/Green

Demand CTRL B1

-

-

+

+

N

N

L

L

0-10V

0-10V

0-10V

0-10V

L

L

L

L

N

N

N

N

N

L

0V

+10V

-

-

+

+

L
N

L
N

L
N

L
N

L
N

L
N

L
N

L
N

L
L
N

+12V

+12V

0V

0V

T2D

+5V

0V

Signal

0-10V

+10V
B (-)
A (+)
GND

Modbus

Содержание COMBI 185 BP

Страница 1: ...COMBI 185 BP INSTALLATION INSTRUCTIONS...

Страница 2: ...ater Sensor Anode 8 Electrical Installation 9 System Inspection and Fine Tuning 9 Optimal Fine Tuning of the System 9 Requirements to the Hot Water Circuit 9 Initial Operation of the Water Circuit 9 C...

Страница 3: ...erve all applicable laws and regulations The water used must be potable grade A reduction valve should be installed if the water pressure is high All connections for potable water must be certified No...

Страница 4: ...ed and as soon as the sensors detect a temperature drop in the tank The com pressor runs until the entire tank has once again reached the set temperature The Combi 185 will normally be able to satisfy...

Страница 5: ...relation to the existing water pressure and pressure loss The aspects of the installation that have to do with water must comply with the local HWS regulations The water pipes can either be made hard...

Страница 6: ...various connectors Fresh Air FRONT Discharge air Supply air Extract air Connecting Supply Air The ducting system leading from the unit to air injected in living quarters Connecting Extract Air The du...

Страница 7: ...tial of the units efficiency it is necessary to insulate the ducts properly Genvex recommends as follows Supply Air and Extract Air Ducts To minimise heat loss from the ducting system in cold lofts in...

Страница 8: ...ank is fitted with a 0 8 m2 heating coil The heat exchanger is enamelled externally The connection is 3 4 RG A sensor controlling external connections such as solar cells an oil burner or a wood burni...

Страница 9: ...7 turns depending on how close they are to the unit Optimal Fine Tuning of the System Use air measuring equipment Check that all 5 items in the section above have been carried out before performing t...

Страница 10: ...tional operational connection can be used if the function of the unit is to be supported by a wood burner or a solar collector installation Sensor T9 see the diagram on the next page measures the temp...

Страница 11: ...rne T5 T6 T8 T9 L8 Eksternt stop L9 Ikke i brug L10 Modulerende For Eftervarme L11 0 10V Motorventil Eftervarme 0 10V Ekstern bypass L16 Modbus L17 0 10V Udsugningsventilator 0 10V Indbl sningsventila...

Страница 12: ...air Sensor supply air External stop EC fan Extract air Blue Yellow EC fan Supply air Blue Yellow Control signal Motorvalve Reheating EC fan Extract air Power supply Motorvalve Reheating External Bypas...

Страница 13: ...2 Vv Varmespiral Kv T8 T7 T9 Solfanger T3 T4 T6 Betjeningspanel T5 T rrefilter Fordamper k leflade Indbl sning MA6 udligningsventil MA5 udligningsventil H jtryks pressostat Bypass T1 T2D T2S Compresso...

Страница 14: ...make sure that the maximum temperature of the do mestic hot water does not exceed 65 C and that the pres sure in the accessory heat exchanger does not exceed 3 bar Comply with all applicable local rul...

Страница 15: ...OPT 312 12 1 040384 Kompressorsamling 13 1 061014 Kompressor Large 13 1 061000 Kompressor small 14 1 045776 Anode Pos Qty Item number Description 1 1 069173 Bypass motor 2 1 045721 Heating element 3 1...

Страница 16: ...16 DECLARATION OF CONFORMITY The declaration of conformity can be found on our website www genvex com...

Страница 17: ...ilies At the same time our system is an important element when it comes to saving energy in homes and in society as a whole in fact you can recover up to 95 of the heat energy with a Genvex system All...

Отзывы: