9
ENGLISH
24 Vdc
3 W
C
M
24V
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17
PE N L
EDGE
W.L.
TX-F
SW
+
LIMITS
ENCODER
MOTOR
ACCESSORIES
LAMP
MAIN
N
L
STOP
+
-
-
OPEN
B
A
OPEN
FSW
OP
FSW
CL
COM
OPEN
CLOSE
LAMP
PE
N
J1
J7
J5
J3
J6
24V
F1
F2
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17
PE N L
ED
G
E
W.
L.
TX-
FSW
+
LIMITS
ENCODER
MOTOR
ACCESSORIES
LAMP
MAIN
N
L
F
+
RADIO
FCA
FCC
OPEN
B
FSW
CL
STOP
SAFE
OPEN
A
FSW
STO
P
+
-
-
OP
EN B
A
OP
EN
FSW
OP
FSW
CL
CO
M
OP
EN
CL
OSE
LAMP
PE
N
ENCODER
EDGE
OP
-
J1
J7
J5
J3
J6
J2
Fig. 1
NB.: The capacitor is supplied with the operator.
Fig. 2
TOTALLY OPEN
PARTIALLY OPEN
STOP
CONTROL BOARD JA383
DL
SIGNALLING AND PROGRAMMING DISPLAY
Led
INPUTS STATUS CONTROL LED
J1
LOW VOLTAGE TERMINAL BOARD
J2
CONNECTOR FOR DECODER/MINIDEC/RP RECEIVER
J3
ENCODER CONNECTOR
J5
LIMIT -SWITCH CONNECTOR
J6
MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD
J7
115 VAC POWER SUPPLY TERMINAL BOARD
F1
MOTORS AND TRANSFORMER PRIMARY WINDING FUSE (F 10A)
F2
LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
F
"F" PROGRAMMING PUSH-BUTTON
–
"–" PROGRAMMING PUSH-BUTTON
+
"+" PROGRAMMING PUSH-BUTTON
F
F1
F2
J1
J2
J3
J5
J6
DL
–
+
Power supply
115 V~ - 50 Hz
Absorbed power
10 W
Motor max. load
1200 W
Accessories max. load
0,5 A
Operating ambient temperature
-20 °C +55 °C
Protection fuses
2 (see fig. 1)
Function logics
Automatic / "Stepped" automatic /
Semi-automatic / Safety devices / Semi-automatic B /
Dead-man C / "Stepped" semi-automatic
Work time
Programmable (from 0 to 4 min.)
Pause time
Programmable (from 0 to 4 min.)
Thrust force
Adjustable over 50 levels
Terminal board inputs
Open / Partial opening / Safety devices at opng. /
Safety devices at clsng. / Stop / Edge / Power Earth
On-connector inputs
Opening and closing limit-switches / Encoder
Terminal board outputs
Flashing lamp - Motor - 24 Vdc accessories power
supply - 24 Vdc indicator-light / Timed output. - Fail safe
Rapid connector
5-pin card connection for Minidec, Decoder or RP receivers
Programming
3 keys (+, -, F) and display, "basic" or "advanced" mode
Basic mode programmable functions
Function logic - Pause time - Thrust
Force - Gate direction
Advanced mode programmable functions
Torque at initial thrust - Braking -
Fail safe - Pre-flashing - Indicator-light/Timed output -
Opening and closing safety devices logic -
Encoder - Decelerations - Partial opening time -
Work time - Assistance request - Cycle counter
For connection of the
photocells and safety
devices, see paragraph
4.1.
BLUE
LIMIT-SWITCH
ENCODER
(optional)
1.
WARNINGS
Important: Before attempting any work on the control board
(connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker with
adequate tripping threshold.
- Connect the earth cable to the appropriate terminal on the J7
connector of the equipment (see fig.2).
- Always separate power cables from control and safety cables
(push-button, receiver, photocells, etc.). To avoid any electric
noise, use separate sheaths or a shielded cable (with earthed
shield).
2.
TECHNICAL SPECIFICATIONS
3.
LAYOUT AND COMPONENTS
Led
J7
4.
ELECTRIC CONNECTIONS
115 Vac
max. 60W
115 Vac
50 Hz
Содержание JA383
Страница 23: ...note notes note notas anmerkung ...
Страница 24: ...note notes note notas anmerkung ...
Страница 25: ...note notes note notas anmerkung ...
Страница 26: ...note notes note notas anmerkung ...