Part No. 102521
S-40 • S-45
3 - 55
October 2013
Section 3 • Scheduled Maintenance Procedures
Perkins models
Required maintenance procedures and additional
engine information are available in the
Perkins 404-22 Operation Manual
(Perkins part number TPD 1443S).
Perkins 404-22 Operation Manual
Genie part number
94890
To access the engine:
Remove the engine tray retaining fasteners
located under the engine tray. Loosen the pivot
fastener located at the platform end of the
engine tray. Swing the engine tray out and
away from the machine and secure it from
moving.
Crushing hazard. Failure to secure
the engine pivot plate from moving
could result in death or serious
injury.
E-6
Perform Engine Maintenance -
Deutz and Perkins Models
Engine specifications require that this procedure be
performed every 5000 hours.
Proper engine maintenance, following the engine
manufacturer's maintenance schedule, is essential
to good engine performance and service life.
Failure to perform the maintenance procedures
can lead to poor engine performance and
component damage.
Required maintenance procedures and additional
engine information are available in the
Deutz 1011F Operation Manual
(Deutz part number 0297 9683) or the
Deutz 2011 Operation Manual
(Deutz part number 0312 3547).
Deutz 1011F Operation Manual
Genie part number
52883
Deutz 2011 Operation Manual
Genie part number
139320
To access the engine:
Remove the engine tray retaining fasteners
located under the engine tray. Loosen the pivot
fastener located at the platform end of the
engine tray. Swing the engine tray out and
away from the machine and secure it from
moving.
Crushing hazard. Failure to secure
the engine pivot plate from moving
could result in death or serious
injury.
CHECKLIST
E
PROCEDURES
Property of American Airlines