  Each opener that you wish to operate must be 

equipped with a 

Network Adapter

 in order to receive 

signals from the Intelligent Wall Console. 

  In order to use the Intelligent Wall Console and

Network Adapter

 equipment—your opener’s powerhead 

must wear this type of label—

 

and must have a 

Network Adapter

 connection port 

(shown below). If you opener does not meet these 

criteria, you cannot use the Intelligent Wall Console.

 

  If you do not have a 

Network Adapter

 or need 

additional Adapters—contact your local Genie® Dealer.

ATTENTION:

Your garage door opener must have a Serial 

10 or higher.

Number sticker that looks like this, in which the first two numbers are 

 

Door

LEFT 

SIDE

NETW

ORK              BBU

NETWORK 

ADAPTER PORT

(must remove rubber cover)

WARNING

Moving Door can cause serious injury 

or death.

•   Wall Console must be mounted in sight 

of door, at least 5 feet above fl oor and 

clear of moving door parts.

•   Keep people clear of opening while door 

is moving

 

•  

If Safety Reverse does not work properly:

o NOT allow children to play with Remote or door opener. 

  fI safety reverse does not work properly: 

•   Close door then disconnect opener using the manual 

release handle.

•   D

D

o NOT use remote or door opener .

•   Refer to door & door opener owner manuals before trying

any repairs. 

NOTE: If, at any time during programming, you receive 

the message ”NO NETWORK” on the display, check 

the following:

  •   Are power wires properly connected to terminals 

      5 & 6 on powerhead? 

  •   Is the Adapter fully inserted and Green Light ON?

  •   Have you linked the IWC with the Adapter?      

(see pg. 8)

Содержание Intelligent Wall Console

Страница 1: ...w geniecompany com SAVE THIS MANUAL FOR FUTURE REFERENCE INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER Genie Genie logo Intellicode Safe T Beam are registered trademarks of GMI Holdings Inc dba The Genie...

Страница 2: ...be usedto enable or disable the motion sensor on the opener s powerhead if so equipped The motion sensor will detect movement inside the garage and turn on the opener s work light The name phonenumbe...

Страница 3: ...SIDE NETWORK BBU NETWORK ADAPTER PORT must remove rubber cover WARNING Moving Door can cause serious injury or death Wall Console must be mounted in sight of door at least 5 feet above floor and clea...

Страница 4: ...wered from only one opener for a group of up to three 1 Using standard 2 conductor bell wire Attach one end to the desired powerhead at terminals 5 6 as shown NOTE The IWC can be used in place of the...

Страница 5: ...ecurely in place If using insulated staples be careful not to pinch or sever the wire Make the staples only snug enough to hold the wire 3 Mount the Console using the screws provided A Unlatch and rem...

Страница 6: ...ll D Attach wires to terminals on the back of the Console E Attach the Console to the mounting bracket by sliding it down over the upper edge of the bracket and swinging it against the bracket until t...

Страница 7: ...7 The Work Light Control buttons can be used to operate the opener s Work Light independently of operating the door opener Work Lights can also be disabled during programming See page 14 Sure Lock ca...

Страница 8: ...2 PRESS RELEASE one of the Opener Control buttons on the IWC The BLUE LED on the Network Adapter will go steady ON 3 PRESS RELEASE the same Opener Control button again The BLUE LED on the Network Ada...

Страница 9: ...s To begin settings press the MENU ICON 2 Next display is the Console Setup Menu Pressing either SCROLL button will cycle through the following categories Scroll back to SETTINGS from the Console Setu...

Страница 10: ...press SELECT YEAR will begin flashing SCROLL to the desired YEAR press SELECT The display will flash DATE SET and return to the SETTINGS menu 1 Pressing the SELECT button to choose TIME FORMAT will pr...

Страница 11: ...TIME will present the following display 2 HOURS flashing SCROLL to desired HOUR press SELECT MINUTES will begin flashing SCROLL to desired MINUTES press SELECT Setting AM PM corresponds with setting o...

Страница 12: ...settings will be lost It is not recommended to use the Sure Lock in areas of frequent power outages OPENER SETTINGS 2 1 Opener 1 2 or 3 SCROLL to the desired opener press SELECT This determines the o...

Страница 13: ...LECT 3 SCROLL to LEARN REMOTE 4 Pressing SELECT will bring up the following display 5 Press the desired remote transmitter button TWICE 6 Press the same button again and the opener will activate The t...

Страница 14: ...ose GET FORCE will present the choices Pressing either SCROLL button will cycle between the following choices Pressing SELECT to choose will display the current force level Adjusting the force is cove...

Страница 15: ...ing group of sub menus CYCLE COUNT 2 Using the SCROLL button to reach the desired function and press SELECT 1 CYCLE COUNT MSG HISTORY and are MOTOR TEMP displays of information and have no user functi...

Страница 16: ...s menu ABOUT IWC 5 4 6 4 5 FCC IC CERTIFIED This device complies with part 15 of the FCC Rules RSS 210 Issue 8 Operation is subject to the following two conditions 1 This device may not cause harmful...

Отзывы: