background image

Gen-Eye SD™ Video Pipe Inspection/Location System  

MAINTENANCE 

CAMERA CLEANING 

After  every  use,  the  camera  should  be  cleaned  and 
checked  for  possible  damage  that  may  have  occurred 
during  the  inspection.    External  scuffing  of  the  camera 
housing is normal and should be of no concern; however, 
use the trap skid to protect the camera and help it slide 
around elbows more easily. 
 
The  camera  lens  is  made  of  sapphire  and  should  be 
cleaned  with  a  soft,  damp  cloth.    Grease,  dirt,  or 
scratches will affect the quality of the video picture.   

DISCONNECT MACHINE FROM POWER 

SOURCE BEFORE PERFORMING          

MAINTENANCE ON MACHINE!

 

CABLE AND REEL ASSEMBLY CLEANING 

WHEN CLEANING THE REEL ASSEMBLY DO NOT 

USE A POWER WASHER.  WATER MAY GET INTO 

UNSEALED AREAS SUCH AS THE REEL HUB AS-

SEMBLY AND SLIP RING HOUSING CAUSING DAM-

AGE AND VOIDING THE WARRANTY.

 

The cable and reel assembly should be kept clean from 
dirt.   When  rewinding  the  cable  back  onto  the  reel  after 
an  inspection,  it  is  good  practice  to  use  a  clean  rag  to 
wipe off any debris the cable may have. 

  TO PREVENT DAMAGE TO THE CAMERA  

AND/OR SYSTEM, DISCONNECT POWER FROM 

THE CONTROL UNIT BEFORE REMOVING OR  

RECONNECTING THE CAMERA TO THE REEL . 

CAMERA REMOVAL FROM THE CABLE 
AND REEL ASSEMBLY 

DISCONNECT MACHINE FROM POWER 

SOURCE BEFORE REMOVING CAMERA 

FROM REEL ASSEMBLY!

 

DO NOT FORCE THE CONNECTORS  

TOGETHER. DAMAGE MAY OCCUR  

TO THE CONNECTORS. 

The camera and associated electronics are not user ser-
viceable.    Servicing should be left to  qualified  personnel 
(your dealer can advise you with regards to service, etc.).  
In the event the camera needs to be returned to the fac-
tory,  the  following  instructions  should  be  used  with  ex-
treme care; to remove the camera head and spring from 
the end of the cable: 
1.  On  standard  reels,  disconnect  the  complete  camera 

and spring assembly by removing the 3 screws (4-40 
x  ½  SSTL)  that  are  countersunk  into  the  cone-
shaped aluminum coupler at the end of the push ca-
ble.    The  screws  can  be  removed  using  the  Xcelite 
allen  wrench  provided  with  the  unit.    Screws  should 
be removed very carefully and simultaneously.  Each 
screw  should  be  turned  approximately  one  (1)  full 
turn alternatively, so as not to damage the connector.  
While  backing  out  each  screw,  hold  the  connector 
and  camera  assembly  together  until  all  the  screws 
are  out  and  then  unplug  the  camera  from  the  cable 
reel taking care not to lose the O-ring or screws. 

2.  After  unplugging  the  camera,  inspect  the  O-ring  for 

any damage, and if worn, replace it with a new one.  
Also, when replacing any O-rings, make sure there is 
no  dirt  or  grit  on  it,  as  it  may  not  seal  properly,  and 
apply  silicon  grease  or  petroleum  jelly  to  the  O-ring 
for proper sealing. 

3.  To  reconnect,  carefully  align  the  rear  connector  on 

the camera assembly, and the cable reel connector.  
When aligned, push the connectors together and re-
place  the  screws.    (If  the  connectors  do  not  align 
properly,  turn  the  camera  body  slowly  while  slightly 
pushing  the  two  connectors  together  until  you  feel 
them align properly together.) 

LIGHT HEAD REPLACEMENT 

The  light  heads  for  the  Gen-Eye  SD  cameras  use  LED 
lighting and cannot be replaced  by  the operator.   These 
lights  use  very  little  power.    Unless  physically  damaged 
or  extreme  voltage  is  applied  to  them,  they  should  last 
indefinitely.    If  replacement  is  necessary,  the  camera 
should be returned to the factory. 
 
The camera lights are wired in a series/parallel configura-
tion.  This means that there are 4 sets of 4 (color camera) 
each wired together.  Each set is wired in series and then 
the  4  sets  are  wired  in  parallel.    Therefore,  should  one 
lamp burn out in one set, the other sets will still remain lit. 

Содержание Gen-Eye SD

Страница 1: ... of trouble free profitable service However no machine is better than its op erator Read understand and follow all safety warnings and instructions provided with the product Failure to follow the warnings and instructions may result in electric shock and or serious injury Save all warn ings and instructions for future reference SAVE THESE INSTRUCTIONS ...

Страница 2: ...ituation Use a UL approved tester to determine if the outlet is safe Do not operate power tools in explosive atmospheres such as in the presence of flamma ble liquids gases or dust Power tools create sparks which may ignite the dust or fumes Always wear safety glasses and rubber soled non slip shoes Use of this safety equip ment may prevent serious injury These instructions are intended to familia...

Страница 3: ...eys or switches before turn ing the tool on A wrench or key that is left attached to a rotating part of the tool may result in personal injury 4 Do not overreach Keep proper footing and bal ance at all times Proper footing and balance en ables better control of the tool in unexpected situa tions 5 Always wear safety glasses and rubber soled non slip shoes Dust mask non skid safety shoes hard hat o...

Страница 4: ...mage to the product due to lightning and power surges 8 Protect against excessive heat The product should be situated away from heat sources such as radia tors heat registers stoves or other products including amplifiers that produce heat ABOUT THE INSPECTION CAMERA The camera although manufactured for the harsh environments in which it will be used should be treated carefully as damage may occur ...

Страница 5: ... the socket end of the AC cord into the AC socket on the panel of the Command Module When using 120 volts AC care should be taken to ensure that it is plugged into a properly grounded receptacle to prevent damage to the unit For DC Voltage Operation Plug the socket end of the DC cord into the DC socket on the panel of the Command Module When using 12 volts DC the unit plugs into a vehicle s cigare...

Страница 6: ...to next line Backspace erases letter and goes back one position ESC ESC followed by 1 9 recalls saved pages on screen CTRL D Set Time Date ENTER to quit CTRL C Reposition counter in one of the four cor ners and the bottom center of the screen CTRL B Type black characters with white border CTRL F Turn flashing characters ON CTRL N Turn flashing characters OFF CTRL W Type white characters KEYBOARD C...

Страница 7: ...mage the cam era on entry or retrieval 5 When negotiating a corner care should be taken not to butt the nose of the camera against the sidewall with any force It would be better to let the camera work its way around the corner If resistance is en countered when turning the corner and there is no visible signs of blockage turning the push rod or pull ing the camera back and forth slowly sometimes h...

Страница 8: ... the gain bar is at the maximum setting 6 Hold the Locator blade vertical and in line with the camera head handle of the Locator at 90 degrees to the camera head If you are not sure of the direction of the pipe hold the locator above the drain opening and rotate it until you obtain the maxi mum signal Note The camera must be stationary to be precisely pinpointed 7 Move the Locator forward and back...

Страница 9: ... from the end of the cable 1 On standard reels disconnect the complete camera and spring assembly by removing the 3 screws 4 40 x SSTL that are countersunk into the cone shaped aluminum coupler at the end of the push ca ble The screws can be removed using the Xcelite allen wrench provided with the unit Screws should be removed very carefully and simultaneously Each screw should be turned approxima...

Страница 10: ...AC line 3 amp and cam era lights 0 25 amp These are rated at 250 volts and are approximately 1 4 diameter x 1 1 4 long IF THE FUSES CONTINUE TO TRIP DO NOT USE THE SYSTEM TRY TO DETERMINE THE CAUSE OR HAVE A QUALIFIED PERSON CHECK OUT THE PROBLEM CAMERA FOCUS All Gen Eye SD cameras are pre focused at the factory from approximately 3 to infinity and should not require any focus adjustments Should f...

Страница 11: ...ug it into the Camera Test Terminal Disconnect the main power and contact the factory service department Dark Picture Check to see if the monitor brightness and contrast controls are turned up Check the Light Head to see if it is not supplying suffi cient light due to weak dirty or burned out bulbs Check to see if the Light Head intensity control is turned up Disconnect the main power source and c...

Страница 12: ...nd the name of the wholesaler from whom you tool was purchased To activate your Gen Eye warranty your warranty card which has this information must be filled out and sent to us im mediately after your machine is purchased 3 We will then advise your wholesaler if the part should be returned to us and as sign a return goods authorization RGA number Ship freight prepaid and you will be compensated fo...