background image

 

 

 

WARNING!  Read  and  understand  all         
instructions. 

Failure  to  follow  all  instructions 

listed  below  may  result  in  electric  shock,  fire 
and/or  serious  personal  injury.  Replacement 
manuals  are  available  upon  request  at  no 
charge, or may be downloaded from our web-
site, 

www.drainbrain.com

.  Instructional  videos 

are available for download on our website, and 
may be ordered.  If you have any questions or 
problems, please call General’s customer  
service department at 412-771-6300. 

 

SAVE THESE INSTRUCTIONS!

 

GENERAL SAFETY RULES 

Gen-Eye SD™ Video Pipe Inspection/Location System  

Electric  shock  resulting  in 
death  can  occur  if  you  plug 
this  machine  into  an  improp-
erly wired outlet.  If the ground 
wire  is  electrified,  you  can  be 
electrocuted  by  just  touching 
the  machine,  even  when  the 
power  switch  is  off.   

A ground 

fault circuit interrupter will not pro-
tect  you  in  this  situation.    Use  a 
UL  approved  tester  to  determine 
if the outlet is safe.

 

 

Do  not  operate  power  tools  in    
explosive  atmospheres,  such 
as  in  the  presence  of  flamma-
ble  liquids,  gases,  or  dust.

  

Power  tools  create  sparks  which 
may ignite the dust or fumes.

 

Always  wear  safety  glasses 
and  rubber  soled,  non-slip 
shoes. 

 

 

Use of this safety equip-

ment may prevent serious injury. 

These instructions are intended to  

familiarize all personnel with the safe  

operation and maintenance  

procedures for the Gen-Eye SD Video 

Pipe Inspection/Location System. 

 

DANGER indicates a hazard with a high level of risk 
which, if not avoided, will result in death or serious injury. 

WARNING indicates a hazard with a medium level of risk 
which, if not avoided, could result in death or serious injury. 

CAUTION indicates a hazard with a low level of risk which, 
if not avoided, will result in minor or moderate injury. 

 

This is the safety alert symbol. It is 

used to alert you to potential personal 

injury hazards. Obey all safety mes-

sages that follow this symbol to avoid 
possible  injury or death.

 

Содержание Gen-Eye SD

Страница 1: ... of trouble free profitable service However no machine is better than its op erator Read understand and follow all safety warnings and instructions provided with the product Failure to follow the warnings and instructions may result in electric shock and or serious injury Save all warn ings and instructions for future reference SAVE THESE INSTRUCTIONS ...

Страница 2: ...ituation Use a UL approved tester to determine if the outlet is safe Do not operate power tools in explosive atmospheres such as in the presence of flamma ble liquids gases or dust Power tools create sparks which may ignite the dust or fumes Always wear safety glasses and rubber soled non slip shoes Use of this safety equip ment may prevent serious injury These instructions are intended to familia...

Страница 3: ...eys or switches before turn ing the tool on A wrench or key that is left attached to a rotating part of the tool may result in personal injury 4 Do not overreach Keep proper footing and bal ance at all times Proper footing and balance en ables better control of the tool in unexpected situa tions 5 Always wear safety glasses and rubber soled non slip shoes Dust mask non skid safety shoes hard hat o...

Страница 4: ...mage to the product due to lightning and power surges 8 Protect against excessive heat The product should be situated away from heat sources such as radia tors heat registers stoves or other products including amplifiers that produce heat ABOUT THE INSPECTION CAMERA The camera although manufactured for the harsh environments in which it will be used should be treated carefully as damage may occur ...

Страница 5: ... the socket end of the AC cord into the AC socket on the panel of the Command Module When using 120 volts AC care should be taken to ensure that it is plugged into a properly grounded receptacle to prevent damage to the unit For DC Voltage Operation Plug the socket end of the DC cord into the DC socket on the panel of the Command Module When using 12 volts DC the unit plugs into a vehicle s cigare...

Страница 6: ...to next line Backspace erases letter and goes back one position ESC ESC followed by 1 9 recalls saved pages on screen CTRL D Set Time Date ENTER to quit CTRL C Reposition counter in one of the four cor ners and the bottom center of the screen CTRL B Type black characters with white border CTRL F Turn flashing characters ON CTRL N Turn flashing characters OFF CTRL W Type white characters KEYBOARD C...

Страница 7: ...mage the cam era on entry or retrieval 5 When negotiating a corner care should be taken not to butt the nose of the camera against the sidewall with any force It would be better to let the camera work its way around the corner If resistance is en countered when turning the corner and there is no visible signs of blockage turning the push rod or pull ing the camera back and forth slowly sometimes h...

Страница 8: ... the gain bar is at the maximum setting 6 Hold the Locator blade vertical and in line with the camera head handle of the Locator at 90 degrees to the camera head If you are not sure of the direction of the pipe hold the locator above the drain opening and rotate it until you obtain the maxi mum signal Note The camera must be stationary to be precisely pinpointed 7 Move the Locator forward and back...

Страница 9: ... from the end of the cable 1 On standard reels disconnect the complete camera and spring assembly by removing the 3 screws 4 40 x SSTL that are countersunk into the cone shaped aluminum coupler at the end of the push ca ble The screws can be removed using the Xcelite allen wrench provided with the unit Screws should be removed very carefully and simultaneously Each screw should be turned approxima...

Страница 10: ...AC line 3 amp and cam era lights 0 25 amp These are rated at 250 volts and are approximately 1 4 diameter x 1 1 4 long IF THE FUSES CONTINUE TO TRIP DO NOT USE THE SYSTEM TRY TO DETERMINE THE CAUSE OR HAVE A QUALIFIED PERSON CHECK OUT THE PROBLEM CAMERA FOCUS All Gen Eye SD cameras are pre focused at the factory from approximately 3 to infinity and should not require any focus adjustments Should f...

Страница 11: ...ug it into the Camera Test Terminal Disconnect the main power and contact the factory service department Dark Picture Check to see if the monitor brightness and contrast controls are turned up Check the Light Head to see if it is not supplying suffi cient light due to weak dirty or burned out bulbs Check to see if the Light Head intensity control is turned up Disconnect the main power source and c...

Страница 12: ...nd the name of the wholesaler from whom you tool was purchased To activate your Gen Eye warranty your warranty card which has this information must be filled out and sent to us im mediately after your machine is purchased 3 We will then advise your wholesaler if the part should be returned to us and as sign a return goods authorization RGA number Ship freight prepaid and you will be compensated fo...

Отзывы: