Gen-Eye SD™ Video Pipe Inspection/Location System
5
Gen-Eye SD Command Module
The SD Command Module
should not be used in wet lo-
cations or in the rain, as mois-
ture may cause damage to the
unit.
Fuses for line voltage, camera
and camera lights are located
behind the LCD monitor panel.
Should replacement become
necessary, replace only with the same value and type as
the original. Never substitute fuses as damage may oc-
cur and may void your warranty. However, if the fuses
continue to trip for no apparent reason, please consult
the factory and do not use the system until the problem
has been determined.
Camera Transmitter (512HZ)
The standard camera system includes a 512 Hz transmit-
ter, which is located safely in the spring behind the cam-
era. When the Command Module is turned on, the trans-
mitter will be automatically activated.
CARE SHOULD BE TAKEN WHEN USING THE
TRANSMITTER IN THE SPRING AS EXCESSIVE
BENDING AND TWISTING MORE THAN 180
DEGREES MAY DAMAGE THE UNIT.
Pre-Inspection Procedure
On arrival to the job site and after checking for a properly
grounded receptacle (see ―Gen-Eye SD Command Mod-
ule‖), set the SD Command Module in an easily viewable
position where it will not interfere with the inspection.
For AC Voltage Operation:
Plug the socket end of the AC cord into the AC socket on
the panel of the Command Module. When using 120
volts AC, care should be taken to ensure that it is
plugged into a properly grounded receptacle to prevent
damage to the unit.
For DC Voltage Operation:
Plug the socket end of the DC cord into the DC socket on
the panel of the Command Module. When using 12 volts
DC, the unit plugs into a vehicle’s cigarette lighter. For
12VDC, the vehicle engine must be running to operate
the camera system.
SET UP
1. Check and make sure the LED Dimmer Control is set
at the ―min‖ position.
2. Unwind the interface cord from the side of the reel
and plug it into the Reel input connector on the panel
of the SD Command Module. Insure the connector is
properly aligned and then tighten.
3. Once all connections have been checked, plug the
other end of the AC cord (or DC cord) into the appro-
priate power source (120VAC or 12VDC).
4. Set the power switch on the Command Module to
either the 120 VAC or 12 VDC position.
Should camera disassembly be required for any rea-
son (for replacing seals, etc.) always ensure the cam-
era has first been cleaned and taken to a clean area
for disassembly. Take extra precaution to avoid dirt
getting into the camera body and any mating compo-
nents such as the nosepiece, main body, and con-
nectors.
THE AC OR DC CORD SHOULD ALWAYS BE
PLUGGED INTO THE SD COMMAND MODULE
FIRST, THEN INTO THE WALL OR 12VDC SOCKET.
NEVER PLUG INTO THE AC SOCKET OR DC