background image

Gen-Eye SD™ Video Pipe Inspection/Location System  

Gen-Eye SD Command Module 

The  SD  Command  Module 
should  not  be  used  in  wet  lo-
cations or in the rain, as mois-
ture may cause damage to the 
unit. 
 
Fuses for line voltage, camera 
and  camera  lights  are  located 
behind the LCD monitor panel. 
Should  replacement  become 

necessary, replace only with the same value and type as 
the original.  Never substitute fuses as damage may oc-
cur  and  may  void  your  warranty.    However,  if  the  fuses 
continue  to  trip  for  no  apparent  reason,  please  consult 
the  factory  and  do  not  use  the  system  until  the  problem 
has been determined.   
 

Camera Transmitter (512HZ) 

The standard camera system includes a 512 Hz transmit-
ter, which is located safely in the spring behind the cam-
era.  When the Command Module is turned on, the trans-
mitter will be automatically activated.   

CARE SHOULD BE TAKEN WHEN USING THE 

TRANSMITTER IN THE SPRING AS EXCESSIVE 

BENDING AND TWISTING MORE THAN 180  

DEGREES MAY DAMAGE THE UNIT.

 

Pre-Inspection Procedure 

On arrival to the job site and after checking for a properly 
grounded receptacle (see ―Gen-Eye SD Command Mod-
ule‖), set the SD Command Module in an easily viewable 
position where it will not interfere with the inspection. 
 

For AC Voltage Operation: 

Plug the socket end of the AC cord into the AC socket on 
the  panel  of  the  Command  Module.    When  using  120 
volts  AC,  care  should  be  taken  to  ensure  that  it  is 
plugged  into  a  properly  grounded  receptacle  to  prevent 
damage to the unit. 
 

For DC Voltage Operation: 

Plug the socket end of the DC cord into the DC socket on 
the panel of the Command Module.  When using 12 volts 
DC,  the  unit  plugs  into  a  vehicle’s  cigarette  lighter.  For 
12VDC,  the  vehicle  engine  must  be  running  to  operate 
the camera system.

 

SET UP 

1.  Check and make sure the LED Dimmer Control is set 

at the ―min‖ position. 

2.  Unwind  the  interface  cord  from  the  side  of  the  reel 

and plug it into the Reel input connector on the panel 
of the SD Command Module.  Insure the connector is 
properly aligned and then tighten. 

3.  Once  all  connections  have  been  checked,  plug  the 

other end of the AC cord (or DC cord) into the appro-
priate power source (120VAC or 12VDC). 

4.  Set  the  power  switch  on  the  Command  Module  to 

either the 120 VAC or 12 VDC position. 

Should camera disassembly be required for any rea-
son (for replacing seals, etc.) always ensure the cam-
era has first been cleaned and taken to a clean area 
for disassembly.  Take extra precaution to avoid dirt 
getting into the camera body and any mating compo-
nents  such  as  the  nosepiece,  main  body,  and  con-
nectors.  

THE AC OR DC CORD SHOULD ALWAYS BE 

PLUGGED INTO THE SD COMMAND MODULE 

FIRST, THEN INTO THE WALL OR 12VDC SOCKET. 

NEVER PLUG INTO THE AC SOCKET OR DC 

Содержание Gen-Eye SD

Страница 1: ... of trouble free profitable service However no machine is better than its op erator Read understand and follow all safety warnings and instructions provided with the product Failure to follow the warnings and instructions may result in electric shock and or serious injury Save all warn ings and instructions for future reference SAVE THESE INSTRUCTIONS ...

Страница 2: ...ituation Use a UL approved tester to determine if the outlet is safe Do not operate power tools in explosive atmospheres such as in the presence of flamma ble liquids gases or dust Power tools create sparks which may ignite the dust or fumes Always wear safety glasses and rubber soled non slip shoes Use of this safety equip ment may prevent serious injury These instructions are intended to familia...

Страница 3: ...eys or switches before turn ing the tool on A wrench or key that is left attached to a rotating part of the tool may result in personal injury 4 Do not overreach Keep proper footing and bal ance at all times Proper footing and balance en ables better control of the tool in unexpected situa tions 5 Always wear safety glasses and rubber soled non slip shoes Dust mask non skid safety shoes hard hat o...

Страница 4: ...mage to the product due to lightning and power surges 8 Protect against excessive heat The product should be situated away from heat sources such as radia tors heat registers stoves or other products including amplifiers that produce heat ABOUT THE INSPECTION CAMERA The camera although manufactured for the harsh environments in which it will be used should be treated carefully as damage may occur ...

Страница 5: ... the socket end of the AC cord into the AC socket on the panel of the Command Module When using 120 volts AC care should be taken to ensure that it is plugged into a properly grounded receptacle to prevent damage to the unit For DC Voltage Operation Plug the socket end of the DC cord into the DC socket on the panel of the Command Module When using 12 volts DC the unit plugs into a vehicle s cigare...

Страница 6: ...to next line Backspace erases letter and goes back one position ESC ESC followed by 1 9 recalls saved pages on screen CTRL D Set Time Date ENTER to quit CTRL C Reposition counter in one of the four cor ners and the bottom center of the screen CTRL B Type black characters with white border CTRL F Turn flashing characters ON CTRL N Turn flashing characters OFF CTRL W Type white characters KEYBOARD C...

Страница 7: ...mage the cam era on entry or retrieval 5 When negotiating a corner care should be taken not to butt the nose of the camera against the sidewall with any force It would be better to let the camera work its way around the corner If resistance is en countered when turning the corner and there is no visible signs of blockage turning the push rod or pull ing the camera back and forth slowly sometimes h...

Страница 8: ... the gain bar is at the maximum setting 6 Hold the Locator blade vertical and in line with the camera head handle of the Locator at 90 degrees to the camera head If you are not sure of the direction of the pipe hold the locator above the drain opening and rotate it until you obtain the maxi mum signal Note The camera must be stationary to be precisely pinpointed 7 Move the Locator forward and back...

Страница 9: ... from the end of the cable 1 On standard reels disconnect the complete camera and spring assembly by removing the 3 screws 4 40 x SSTL that are countersunk into the cone shaped aluminum coupler at the end of the push ca ble The screws can be removed using the Xcelite allen wrench provided with the unit Screws should be removed very carefully and simultaneously Each screw should be turned approxima...

Страница 10: ...AC line 3 amp and cam era lights 0 25 amp These are rated at 250 volts and are approximately 1 4 diameter x 1 1 4 long IF THE FUSES CONTINUE TO TRIP DO NOT USE THE SYSTEM TRY TO DETERMINE THE CAUSE OR HAVE A QUALIFIED PERSON CHECK OUT THE PROBLEM CAMERA FOCUS All Gen Eye SD cameras are pre focused at the factory from approximately 3 to infinity and should not require any focus adjustments Should f...

Страница 11: ...ug it into the Camera Test Terminal Disconnect the main power and contact the factory service department Dark Picture Check to see if the monitor brightness and contrast controls are turned up Check the Light Head to see if it is not supplying suffi cient light due to weak dirty or burned out bulbs Check to see if the Light Head intensity control is turned up Disconnect the main power source and c...

Страница 12: ...nd the name of the wholesaler from whom you tool was purchased To activate your Gen Eye warranty your warranty card which has this information must be filled out and sent to us im mediately after your machine is purchased 3 We will then advise your wholesaler if the part should be returned to us and as sign a return goods authorization RGA number Ship freight prepaid and you will be compensated fo...